Raypak 926-1758 - Manual

Raypak 926-1758

Raypak 926-1758 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

Catalog No.: 2000.22N

Effective: 12-1-07

Replaces: 10-15-03

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

EFFICIENT

82% thermal efficiency – highest of any atmospheric
boiler available today

THERMAL SHOCK PROOF

Twenty-year warranty against thermal shock damage
up to 150°F differential

Maximum operating temperature: 230°F

LIGHTWEIGHT

A floor load of 70 lbs./sq. ft. or less

HIGH RECOVERY

Cuts fuel costs substantially because the standby and
radiation losses normal to other boilers are eliminated

LOW WATER OPERATING TEMPERATURE

Operates with water temperature as low as 105°F
without condensing

Heat Exchanger

ƒ

ASME Inspected and Stamped

160 PSIG

ƒ

National Board Approved

ƒ

Headers

Glass-lined Cast Iron – Standard
Bronze – Option A-1

ƒ

Finned

Tubing

Copper – Standard
Cupro Nickel – Option A-3

ƒ

ASME Steel Tube Sheet

ƒ

Silicone

O-Rings

ƒ

60 PSIG ASME Pressure Relief Valve

ƒ

Temperature and Pressure Gauge

(Boiler)

ƒ

Water

Connections

Left Hand – Standard
Right Hand – Option A-6

ƒ

Flow

Configuration

Two-pass – Standard
Single-pass (Cast Iron Only)

ƒ

Pump, Rear-mounted (Optional)

4.25” Impeller
4.7” Impeller

Controls

ƒ

120V, 60Hz, 1 Ph Power Supply

ƒ

120/24V

Transformer

ƒ

100% Pilot Shut-off/Lockout

ƒ

Electronic, Intermittent Ignition (IID)

Pilot

ƒ

High Limit Control, Manual Reset

Controls (cont.)

ƒ

On/Off

Switch

ƒ

Flow

Switch

ƒ

Economaster II Pump Time Delay


Gas Control Train

ƒ

Manual Main Gas Shut-off Cock

ƒ

Main Gas Pressure Regulator

ƒ

Redundant Safety Shut-off Valve

ƒ

Control Valve

ƒ

Firing

Mode

On/off (H4)
Two-stage Firing (H3)
Four-stage Firing (H9)
Mechanical Modulation,

110-170°F (H5)

Mechanical Modulation,

150-210°F (H1)

Motorized Modulation (H2)
B-6000 (H6)

ƒ

Fuel

Natural Gas
Propane Gas

ƒ

Design Certified ANSI Z21.13/CSA 4.9

Construction

ƒ

Front

Controls

ƒ

Stainless Steel Burners

ƒ

Polytuf Powder Coat Finish

ƒ

Stackless

Top

ƒ

Base

(Optional)

Combustible Floor Shield – Option J-1


Temperature Controllers

Note: H1 and H5 do not require a controller

B-7

Modulating

B-5

Modulating, Outdoor Reset

B-6

Two-stage

B- Four-stage Digital
Y-241 Electronic Sequencer,

1-4 Stages

Y-281 Electronic Sequencer,

1-8 Stages

Additional Safety Controls

F-9

Low Water Cut-off Probe

I-1

High Limit Control,
Auto Reset

S-1

Low Gas Pressure Switch

S-2

High Gas Pressure Switch

Regulatory Agency Requirements

Raytherm

®

- Type H

Hydronic Heating Boilers

Commercial

Models 926-1758 (Outdoor)

Fig. #8953

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Raypak Models

All Raypak Other