Catalog No.: 2000.36G

Effective: 2-1-08

Replaces: 5-1-05

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

Indoor/Outdoor:

100% Factory Fire Tested

Efficiency: 84%

Maximum Outlet Temperature: 230°F

Minimum Non-Condensing Inlet Temperature: 105°F

Thermal Shock Proof Heat Exchanger

Footprint: Less Than 5-1/2 ft

2

Limited Twenty-Year Thermal Shock Warranty

Limited Ten-Year Heat Exchanger Warranty

Ten-Year Unconditional Burner Head Warranty

Operation Status Center and Full Diagnostic Panel

Heat Exchanger

ƒ

Bronze Headers

ƒ

ASME Inspected and Stamped

160 PSIG Working Pressure

ƒ

National Board Approved

ƒ

Copper-finned Tubes

ƒ

ASME Steel Tube Retainer

ƒ

Silicone High Temp O-Rings

ƒ

60 PSIG ASME Pressure Relief

Valve

ƒ

Temperature and Pressure Gauge,

Shipped Loose

Control

ƒ

120V, 60Hz, Power Supply

ƒ

120/24V 60Hz Transformer

ƒ

100% Pilot Shutoff/Lockout

ƒ

Electronic Intermittent Ignition Pilot

(IID)

ƒ

High Limit Control, Manual Reset

ƒ

High Limit Control, Auto Reset

ƒ

On/Off Switch

ƒ

Flow Switch

ƒ

Blocked Vent Pressure Switch

ƒ

Combustion Air Proving Switch

ƒ

Time Delay Pump Off Control

ƒ

Central Point Wiring Diagnostics

Panel

Burner

ƒ

Aerodynamically Stabilized

Non-Clog Burner

ƒ

Ultra-Low NOx: Less than 30 PPM

Gas Train

ƒ

Fuel

Natural Gas
Propane (Models 751 & 1001)

ƒ

Manual Gas Shut-off Valves

ƒ

Gas Pressure Regulator

ƒ

Safety Shut-off Valve

ƒ

Firing Control Valve

ƒ

Manual Low Gas Pressure Switch

ƒ

On/Off Firing Mode (H4)

ƒ

Design Certified ANSI Z21.13/

CSA 4.9

Construction

ƒ

Indoor/Outdoor Construction

ƒ

Front Controls Enclosed

ƒ

PolyTuf Powder Coat Finish

ƒ

Connections (Water, Electrical,

Gas)

Rear – Standard
Right Side – Option A-8

Venting

ƒ

Vent Location

Rear – Standard
Right Side – Option Z-2

ƒ

Vent Termination Cap

Outdoor - Option D-11
Indoor, Horizontal – Option D-15
Indoor, Vertical (by others)

Temperature Controls

B-20

Single-Stage Controller,
100-200°F

B-6

2-Stage Controller, 100-200°F

B-21

4-Stage TempTracker Digital
Controller, Loose

B-23

4-Stage TempTracker Digital
Controller, Outdoor Reset, Loose

Y-241 Electronic Sequencer,

1-4 Stages

Y-281 Electronic Sequencer,

5-8 Stages

Additional Safety Controls (Optional)

F-10

Low Water Cut-off,
Remote Probe

S-2

Manual High Gas Pressure
Switch

Regulatory Agency Requirements

C-5

Ignition Lockout Module

Other Equipment

Condensing Heat Exchanger

Pump



ADB™ - Type H

Hydronic Heating Boilers