Raypak 399B - Manual
Raypak 399B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Catalog No.: 2000.461A
Effective: 07-21-10
Replaces: 9-15-07
Job:
Engineer:
Contractor:
Prepared By:
Date:
Model:
Indoor/Outdoor:
MBTUH Input:
100% Factory Fire Tested
Efficiency: 84%
Maximum Outlet Temperature: 230°F
Minimum Non-Condensing Inlet Temperature: 105°F
Thermal Shock Proof Heat Exchanger
Limited Twenty-Year Thermal Shock Warranty
Limited Ten-Year Closed-System Heat Exchanger
Warranty
PolyTuf Powder Coated Cabinet
No Combustible Floor Shield Required
Fan-Assisted
Patented Burner Security Blanket
Heat Exchanger
H
Stamp
Headers
Glass-Lined Cast Iron – Standard
Bronze – Option A-1
ASME Inspected and Stamped
160 PSIG Working Pressure
National Board Approved
Fin
Tubing
Copper – Standard
Cupro Nickel – Option A-3
ASME Steel Tube Sheet
Silicone High Temp O-Rings
Pressure Relief Valve, ASME
45 PSIG – Standard on Model 399B
60 PSIG – Standard on Models
499B-899B
PSIG – Optional
Temperature and Pressure Gauge
Water
Connections
Left – Standard
Right – Option A-6
Controls
120V, 60Hz, 1 Phase Power Supply
120/24V 60Hz Transformer
100%
Shut-Off/Lockout
Hot Surface Ignition
Remote Flame Sensor
High Limit Control, Manual Reset
On/Off Power Switch
Manual Shut-Off, Front-Mounted Switch
Flow
Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switch
Pump Time Delay Relay
Status
Display
Lights
Gas Train
Manual Gas Shut-Off Valve(s)
Combination
Valves
Firing
Mode
On/Off: Model 399B
2-Stage: Models
499B-899B
Fuel
Natural Gas
Propane Gas
Design Certified - ANSI
Z21.13/CSA 4.9
Burner
Ultra-Low NOx: Less than
20 PPM
Construction
Indoor/Outdoor
Construction
Enclosed Front Controls
Venting
Vent
Location
Top, Outdoor – Standard
Top, Indoor – Option D-20
Rear – Option D-14
Vent Termination Cap
Outdoor D-11
Indoor, Horizontal D-15
Indoor, Vertical (by others)
Extractor – Optional
By others
Not required
Temperature Controls
B-2
Tankstat, Single-Stage
(100-200°F)
B-3
Tankstat, 2-Stage (100-200°F)
B-6
Aquastat, 2-Stage (100-200°F)
B-__ TempTracker Digital Controller,
2-Stage (Loose)
B-__ TempTracker Digital Controller,
4-Stage (Loose)
Options
C-6 Ignition Module, Manual Reset
F-10 Low Water Cut-Off, Remote Probe
I-1
High Limit Control, Auto Reset
P- Pump: HP, 120V, 1
∅
, 60Hz
Water Hardness: GPG
Cast Iron
Bronze
Mounted
Loose
Front
Rear
P-26 Cold Water Start (See 2000.48)
S-1
Low Gas Pressure Switch, Manual
S-2
High Gas Pressure Switch,
Manual
X-1 SureRack™ Kit
X-2 SureRack Add-on
Regulatory Agency Requirements
Delta Limited™ - Type H
Space Heating/Hot Water Boilers
Models 399B-899B
Shown with outdoor
air inlet and pump covers
Proudly Made in the U.S.A
Delta Limited models not approved for use in California