Catalog No.: 2000.303A

Effective: 11-15-07

Replaces: 8-15-07

Job:

Engineer:

Contractor:

Preparer:

Date:

Model:

Indoor/Outdoor:

MBTUH Input:

Fast, Economical Natural-to-Propane Gas Switchover
100% Factory Fire Tested
84% Efficiency
Maximum Outlet Temperature: 230°F
Minimum Non-Condensing Inlet Temperature: 105°F
Thermal Shock Proof Heat Exchanger
Limited Twenty-Year Thermal Shock Warranty
Diagnostic Center with Fault History
PolyTuf Powder Coated Cabinet
No Combustible Floor Shield Required
Fan-Assisted Low NOx Burners
Patented Burner Security Blanket

Heat Exchanger

ƒ

H

Stamp

ƒ

Headers

Glass-Lined Cast Iron – Standard
Bronze – Option A-1

ƒ

ASME Inspected and Stamped

160 PSIG Working Pressure

ƒ

National Board Approved

ƒ

Fin

Tubing

Copper – Standard
Cupro Nickel – Option A-3

ƒ

ASME Steel Tube Sheet

ƒ

Silicone High Temp. O-Rings

ƒ

ASME Pressure Relief Valve

45 PSIG – Standard on Models

302BD and 402BD

60 PSIG – Standard on Models

502BD-902BD

PSIG – Optional

ƒ

Temperature and Pressure Gauge

ƒ

Water

Connections

Left – Standard
Right – Option A-6

Controls

ƒ

120V, 60Hz, 1

Power Supply

ƒ

120/24V 60Hz Transformer

ƒ

100%

Shut-Off/Lockout

ƒ

Hot Surface Ignition

ƒ

Remote Flame Sensor

ƒ

High Limit Control, Manual Reset

ƒ

On/Off Power Switch

ƒ

Manual

Shut-Off,

Front-Mounted

ƒ

Flow

Switch

ƒ

Blocked Vent Pressure Switch

ƒ

Combustion Air Proving Switch

ƒ

Economaster Pump Time Delay

ƒ

Enable/Disable

Gas Train

ƒ

Manual Gas Shut-Off Valve(s)

ƒ

Gas

Pressure

Regulator

ƒ

Safety Shut-Off Valve

ƒ

Firing

Control

Valve

ƒ

Firing

Mode

On/Off (H8): Models 302BD,

402BD

2-Stage (H9): Models

302BD-902BD

ƒ

Natural/Propane

Gas

ƒ

Design Certified ANSI Z21.13/

CSA 4.9

ƒ

Gas

Connection

Left – Standard
Right – Option Z-1

ƒ

Construction

ƒ

Indoor/Outdoor

Construction

ƒ

Enclosed Front Controls

Venting

ƒ

Vent

Location

Top – Standard
Rear – Option D-14

ƒ

Vent Termination Cap

Outdoor D-11
Indoor, Horizontal D-15
Indoor, Vertical (by others)

ƒ

Combustion

Air

In-Line Filter Kit (TruSeal

only) D-17

Air Intake Elbow D-16

ƒ

Extractor – Optional

By others
Not required

Burner

ƒ

Ultra-Low NOx: Less than 30 PPM

Temperature Controls

B-2

Tankstat, Single-Stage
(100-200°F)

B-3

Tankstat, 2-Stage (100-200°F)

B-6

Aquastat, 2-Stage (100-200°F)

B- TempTracker

Digital

Controller,

2-Stage

B- TempTracker

Digital

Controller,

4-Stage

Y-241 Electronic Sequencer, 4-Stage
Y-281 Electronic Sequencer, 8-Stage

Options

C-6

Ignition Module, Manual Reset

D-21 TruSeal

®

Direct Vent

F-10 Low Water Cut-Off, Remote Probe
I-1

High Limit Control, Auto Reset

P- Pump: HP, 120V, 1

, 60Hz

Water Hardness: GPG

Cast Iron

Bronze

Mounted

Loose

Front

Rear

P-26 Cold Water Start (See 2000.48)
S-1

Low Gas Pressure Switch, Manual

S-2

High Gas Pressure Switch, Manual

X-1

SureRack™ Kit

X-2

SureRack Add-on

Regulatory Agency Requirements

Hi Delta

®

FlexGas

®

-

Type H

Dual-Fuel Hot Water Boilers

Models 302BD-902BD

Patent Nos. 6,904,873 & 7,044,124;
other patents pending