Catalog No.: 2000.17

Effective: 6-22-09

Replaces: New

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

Indoor/Outdoor:

Up to 94% Thermal Efficiency at Full Rate

100% Factory Fire Tested

Maximum Outlet Water Temperature: 210°F

Maximum System Temperature: 200°F

Full Safety Diagnostics with History

Footprint: Less Than 9-1/2 ft

2

Limited Twenty-Year Thermal Shock Warranty

Limited Ten-Year Heat Exchanger Warranty

Full Electronic Modulation, Constant Ratio 5:1 Turndown

Soft-Start Modulating Controller with LCD Display

Status and Full Diagnostics Display

Heat Exchanger

ƒ

All Stainless Steel Construction

ƒ

Gasketless Heat Exchanger Design

ƒ

ASME H Stamped

160 PSIG Working Pressure

ƒ

National Board Approved

ƒ

ASME Pressure Relief Valve

60 PSIG – Standard
PSIG – Optional

ƒ

Temperature and Pressure Gauge,

Shipped Loose

Control

ƒ

120V, 60Hz, 1Ø, Power Supply

ƒ

Digital Operating Control with LCD

display.

ƒ

Outdoor reset with Indirect Priority

ƒ

0-10 VDC input for BMS

ƒ

Cascade up to 8 boilers

ƒ

Spark Ignition (IID)

ƒ

Remote Flame Sensor

ƒ

High Limit, Manual Reset, Fixed,

200ºF

ƒ

Auto Limit, Fixed, 210ºF

ƒ

Alarm Dry Contact Connection

ƒ

On/Off Power Switch

ƒ

Flow Switch

ƒ

Blocked Vent Pressure Switch

ƒ

Boiler, DHW & System Pump

Contacts

ƒ

Water Temperature Sensors (3)

Burner

ƒ

Ultra-Low NOx: Less than 20 PPM

Gas Train

ƒ

Fuel

Natural Gas
Propane

ƒ

Zero Governor Regulator

ƒ

Dual-Seat Combination Valve

ƒ

Electronic Modulating Firing Mode (H7)

Construction

ƒ

Indoor/Outdoor Construction

ƒ

Front Controls Enclosed

ƒ

PolyTuf Powder Coat Finish

ƒ

Rear Connections (Electrical, Gas, Vent,

Combustion Air)

ƒ

Top Connections (Water)

ƒ

Design Certified ANSI Z21.13/

CSA 4.9

Venting (PVC-CPVC-Stainless.)

ƒ

Vent Termination

Indoor, Vertical – Option D-11
Indoor, Horizontal – Option D-15
Outdoor

ƒ

Extractor - Optional

By others
Not required

Multi-Boiler System Controllers

B-36 TempTracker Mod+ Digital

Controller, 2-4 Boilers, OA Reset

B-37 TempTracker Mod+ Digital

Controller, 5-10 Boilers, OA Reset

B-38 TempTracker Mod+ Digital

Controller, 11-16 Boilers, OA Reset

Options

D-21 TruSeal™ Combustion Air Inlet
P- Pump: HP, 120V, 1

, 60Hz

Cast Iron

Bronze

S-1

Low Gas Pressure Switch,
Manual Reset

S-2

High Gas Pressure Switch,
Manual Reset

Z-12 Condensate Neutralizer Kit

Regulatory Agency Requirements