Catalog No.: 6000.37

Effective: 9-15-08

Replaces: NEW

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

Indoor/Outdoor:

97% Thermal Efficiency at Full Rate; Up to 99% at Part Load

100% Factory Fire Tested

Maximum Outlet Water Temperature: 160°F

Minimum Acceptable Inlet Water Temperature: 50°F

Full Safety Diagnostics with History

Footprint: Less Than 10.8 ft

2

Limited Twenty-Five-Year Thermal Shock Warranty

Limited Ten-Year Primary Heat Exchanger Warranty

Limited Five-Year Secondary Heat Exchanger Warranty

Full Electronic Modulation, Constant Ratio 4:1 Turndown

Digital Controller with LCD Display

Status Display Lights

Heat Exchanger

ƒ

Bronze Headers

ƒ

ASME HLW Stamped; 160 PSIG

MAWP

ƒ

National Board Listed

ƒ

Cupro Nickel Fin Tubing

ƒ

ASME Powder-Coated Tube Sheet

ƒ

Silicone High Temp O-Rings

ƒ

ASME Pressure Relief Valve

125 PSIG – Standard (Loose)

ƒ

150 PSI Air Vent, Auto

ƒ

T&P Gauge (Loose)

ƒ

Stainless Steel Secondary Heat

Exchanger

ƒ

Stainless Steel Evaporator Plate

ƒ

Boiler Pump: Bronze, HP,

120V, 1

, 60Hz

Control

ƒ

120V, 60Hz, 1Ø, Power Supply

ƒ

120/24V 60Hz Transformer

ƒ

Ignition Module

3-Try – Standard
Single-Try – Option C-6

ƒ

Hot Surface Ignition (HSI)

ƒ

Remote Flame Sensor

ƒ

High Limit Control, Auto Reset

ƒ

On/Off Power Switch

ƒ

Flow Switch

ƒ

Blocked Vent Pressure Switch

ƒ

Combustion Air Proving Switch

ƒ

Freeze Protection

ƒ

Pump Switch

ƒ

Pump Time Delay

ƒ

Blocked Condensate Switch

Control (cont.)

ƒ

Diagnostics Panel with LCD Display,

2 lines, 20 characters

ƒ

Digital Temperature Control

ƒ

Water Temperature Sensors (3)

ƒ

Cold Water Protection

Burner

ƒ

Ultra-Low NOx: Less than 20 PPM

(Natural Gas Only)

Gas Train

ƒ

Fuel

Natural Gas
Propane

ƒ

Zero Governor Regulator

ƒ

Dual-Seat Combination Valve

ƒ

Electronic Firing Mode (WHP)

Construction

ƒ

Indoor/Outdoor Construction

ƒ

Front Controls Enclosed

ƒ

PolyTuf Powder Coat Finish

ƒ

Rear Connections (Water, Gas, Vent,

Electrical, Comb. Air, Cond. Drain)

ƒ

Combustion Air Filter

ƒ

Design Certified ANSI Z21.10.3/CSA 4.3

Venting

ƒ

Vent Termination

Outdoor or Indoor, Vertical –

Option D-11

Indoor, Horizontal – Option D-15

ƒ

Extractor - Optional

By others
Not required


Multi-Boiler Digital Temp Controllers

B-36 TempTracker Mod+,

2-4 Water Heaters

B-37 TempTracker Mod+,

5-10 Water Heaters

B-38 TempTracker Mod+,

11-16 Water Heaters

Options

F-10 Low Water Cut-Off, Remote

Probe

I-5

High Limit, Manual Reset,
Adj., 100-200

°

F

S-1

Low Gas Pressure Switch,
Manual Reset

S-2

High Gas Pressure Switch,
Manual Reset

Z-12 Condensate Neutralizer Kit

Regulatory Agency Requirements

XTherm

- Type WHP

Water Heaters

Models 1005-2005

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Raypak Models

All Raypak Other