Raypak 0090B - Manual

Raypak 0090B

Raypak 0090B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
Page: / 39

Table of Contents:

  • Page 2 – CALIFORNIA PROPOSITION 65 WARNING:; cause cancer, birth defects or other reproductive harm.; Contents
  • Page 3 – RECEIVING EQUIPMENT; report the damage to; GENERAL SPECIFICATIONS
  • Page 4 – INSTALLATION PROCEDURES; The boiler should be located in an area where
  • Page 5 – two; If louvers, grills or screens are used on the; wood
  • Page 6 – ANSI; or applicable provisions of the local building; COMMON VENTS; Roof Pitch
  • Page 7 – Read carefully and follow the installation
  • Page 8 – MOUNTING; do not; to the side of the vent.; Hole in Vent Damper Blade; D80D GENERAL WIRING DIAGRAM
  • Page 9 – To place vent damper in the; VENT DAMPER OPERATION; Check vent damper operation as follows:; FLAIR DAMPER; SYSTEM SCHEMATIC; contacts
  • Page 10 – CONNECTION DIAGRAM
  • Page 11 – The boiler and its manual shut-off valve must be; Do not use teflon tape on gas line pipe thread.; GAS PRESSURE; Sediment Trap Gas Valve
  • Page 12 – PIPING DIAGRAMS
  • Page 15 – WIRING DIAGRAM KEY; If it is necessary to replace any of the original; ELECTRICAL WIRING; The electrical power supply requirement for these
  • Page 19 – WIRING DIAGRAM: Dual-Zone Honeywell Valve
  • Page 20 – WIRING DIAGRAM: Power Vent System w/ Zone Valve
  • Page 23 – SERVICING PROCEDURES; GENERAL LOCATION OF CONTROLS; Relay; SEQUENCE OF OPERATION
  • Page 24 – Lighting the Boiler; Propane gas is heavier than air and sinks to; BEFORE LIGHTING; Circulator motor supplied with the boiler does
  • Page 25 – FOR AUTOMATIC IGNITION MODELS.; If you do not follow these instructions; BEFORE OPERATING; GAS INLET; HONEYWELL PILOT ROBERTSHAW PILOT
  • Page 26 – HONEYWELL; HONEYWELL PILOT
  • Page 27 – Should overheating occur or the gas supply; FOR AUTOMATIC IGNITION SYSTEMS
  • Page 28 – Modulating burner flame varies in height from
  • Page 29 – REPAIR PROCEDURES
  • Page 31 – TROUBLESHOOTING GUIDE; IMPORTANT NOTICE; PROBLEM
  • Page 33 – DANGER - SHOCK HAZARD; Make sure pilot orifice is clear, but do not; PILOT
  • Page 34 – REPLACEMENT PARTS LIST; To supply the correct part it is important that you; CAUTION; To avoid damage to electrical components
  • Page 39 – Raypak Canada LTD
Loading the manual

Catalog No.: 2100.50V
Effective:

04-01-04

Replaces: 01-01-03

P/N 240488

THIS MANUAL SHOULD BE MAINTAINED IN LEGIBLE CONDI-
TION AND KEPT ADJACENT TO THE BOILER OR IN A SAFE
PLACE FOR FUTURE REFERENCE.

INSTALLATION
AND OPERATING
INSTRUCTIONS

Raytherm

TM

Type H

RESIDENTIAL BOILERS

Models
0030B, 0042B, 0066B,0090B
0135B, 0180B

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids or other combustible materials
in the vicinity of this or any other appliance. To do so may result in an explosion or fire.

WARNING:

Improper installation, adjustment, alteration, service or maintenance can cause

property damage, personal injury or loss of life. Refer to the user's information manual provided
with this boiler. Installation and service must be performed by a qualified installer, service agency
or the gas supplier.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS
*Do not try to light any appliance.
*Do not touch any electrical switch; do not use any phone in your building.
*Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
*If you cannot reach your gas supplier, call the fire department.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CALIFORNIA PROPOSITION 65 WARNING:; cause cancer, birth defects or other reproductive harm.; Contents

CALIFORNIA PROPOSITION 65 WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. These instructions are provided to assure the proper installation and operation of Raypak boilers. Should questionsarise regarding the specif...

Page 3 - RECEIVING EQUIPMENT; report the damage to; GENERAL SPECIFICATIONS

Follow the installation instructions furnished with the ventdamper package. The plug-in connector can also beused with power venters. Refer to the specific installationinstructions supplied by the power vent manufacturer. SPECIFICATIONS AND DIMENSIONS 3 Fig. #8978.1 RECEIVING EQUIPMENT On receipt of...

Page 4 - INSTALLATION PROCEDURES; The boiler should be located in an area where

3. INSTALLATION PROCEDURES CODE REQUIREMENTS Installation must be in accordance with local codes , or, in the absence of local codes, with the latest editions of the National Fuel Gas Code , ANSI Z223.1 , and the National Electrical Code , ANSI/NFPA 70. In Canada, installations must conform with the...

Other Raypak Models

All Raypak Other