Page 3 - iii; Table Of Contents; Preface
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Table Of Contents iii Table Of Contents Preface 1 How to Use This Manual 1 Intended Audience 2 Related Materials 2 Ancor Customer Service 3 Safety Notices 3 Communications Statements 6 Laser Safety Information 9 Acces...
Page 4 - iv
iv Table Of Contents GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Table Of Contents 3. Switch Management 3-1 Introduction 3-1 GigWorks MKII Switch Utilities 3-3 Trivial File Transfer Protocol (TFTP) 3-3 Simple Network Management Protocol (SNMP) 3-4 Ethernet Cab...
Page 5 - Appendix A: Reference Information
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Table Of Contents v 3-54 Community Types 3-55 Operation Types 3-56 Management Information Bases (MIBs) 3-57 Configuring SNMP 4. Diagnostics/Troubleshooting 4-1 Introduction 4-1 Power Supply Troubleshooting 4-5 Power-O...
Page 6 - Appendix C: Chassis Switch Panel
vi Table Of Contents GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Appendix C: Chassis Switch Panel C-1 Chassis Switch Panel C-2 Reset C-2 Force Prom Mode C-2 Watch Dog Timer Disable C-3 Test Mode C-4 Chassis#, Fabric#, Stage#, and Area# Configuration Switches L...
Page 7 - How to Use This Manual; This manual has five sections and three appendixes:; Intended Audience
GigWorks MKII-16 SwitchModel MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Preface 1 Preface How to Use This Manual This manual has five sections and three appendixes: • Section 1 is an overview of the GigWorks™ MKII-16 Switch Model MKII-BASE16. It describes indicator lights and all user cont...
Page 8 - Related Materials; The following Fibre Channel Standards:; Ancor Customer Service
2 Preface GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Related Materials The following manuals and materials are referenced in the text and/or provideadditional information. • The following Fibre Channel Standards: Fibre Channel Physical and Signaling Interface...
Page 9 - Communications Statements; Safety Notices; Federal Communications Commission (FCC) Class A Statement
GigWorks MKII-16 SwitchModel MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Preface 3 Communications Statements Safety Notices A Danger notice indicates the presence of a hazard that has the potential ofcausing death or serious personal injury. Danger notices appear on the followingpages: 2-5,...
Page 11 - VCCI Class A Statement
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Table Of Contents 5 VCCI Class A Statement Translation: This is a Class A product based on the standard of the Voluntary Control CouncilFor Interference by Information Technology Equipment (VCCI). If thisequipment is ...
Page 12 - Laser Safety Information; Certification and Classification Information
6 Preface GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Laser Safety Information Laser Safety Information The GigWorks 1062/16 MKII Switch may use Class 1 lasers to communicateover the fiber optic conductors. The U.S. Department of Health and HumanServices (DHHS...
Page 13 - Optical GBICs
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Table Of Contents 7 Optical GBICs Each optical GBIC is a single communications port. Each communications portconsists of a transmitter and receiver optical subassembly. The transmittersubassembly contains internally a...
Page 14 - Labeling Requirements
8 Table Of Contents GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Labeling Requirements There are no caution or danger labels required for use of the optical GBIC since itis a Class 1 laser component assembly. Within the U.S., the only laser safety labelrequired...
Page 15 - fuses associated with the AC power input,; Pièces Accessibles; Fusibles associés à l’entrée de courant c.a.; Zugängliche Teile; Sicherungen für den Wechselstromeingang; Accessible Parts
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Table Of Contents 9 Accessible Parts The only Field Replaceable Units (FRUs) in the GigWorks MKII-16 SwitchModel MKII-BASE16 are: • fuses associated with the AC power input, • power supply(s), and • interfaces to the ...
Page 17 - Section 1; GigWorksTM MKII-16 Switch Model MKII-BASE16 General Description; Major Fibre Channel Port Features; Major Fibre Channel port features include:
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A General Description 1-1 Section 1 GigWorks™ MKII-16 Switch Model MKII-BASE16 General Description GigWorks™ MKII-16 Switch Model MKII-BASE16 General Description The Switch is the Fabric component of a Fibre Channel com...
Page 18 - The Switch supports management through:
1-2 General Description GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual General Description • All ports used as F_Ports support Class 1, Class 2, Class 3, and IntermixFibre Channel service. Refer to the Reference Information appendix formore information. • All por...
Page 20 - Retrieve and modify the Switch file named; Major Switch Chassis Features
1-4 General Description GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual General Description of these Broadcast Zones. A port will broadcast to all ports in the sameBroadcast Zone (or zones) in-which the port is defined. If Hard Zones areenabled, Broadcast Zones ma...
Page 22 - Figure 1-2 Chassis Front; TX; TX
1-6 General Description GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual General Description Figure 1-2 Chassis Front Continuous Test button(Must be OFF (IN) for normal operation) Power Supply Fail LED (Red) Over Temperature LED (Red) Logic Power Good LED (Green) H...
Page 23 - Currently, the following GBICs are certified for use:
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A General Description 1-7 General Description Currently, the following GBICs are certified for use: Short-wavelength fiber optic GBICs 100-M5-SL-I or 100-M6-SL-I withOpen Fiber Control (OFC) support connection to legacy...
Page 24 - Front Panel LEDs
1-8 General Description GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual General Description Front Panel Controls Power Button Figure 1-2 shows the location of the Power Button. The Power Button isprotected by a clear plastic cover that must be flipped UP in order ...
Page 26 - Figure 1-4 Chassis Back
1-10 General Description GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual General Description time or several times over a short period of time when they are powered up.If the Switch was not operable at that time, it would miss this login attemptand the attached no...
Page 29 - Section 2; Installation
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Installation 2-1 Section 2 Installation Installation There are seven basic steps required to install the Switch. 1. Unpack 2. Place or Mount the Equipment 3. Apply the IEC Laser Safety Label (If the installation is in...
Page 30 - Remove the two Side-Fillers. They are each secured with six captive
2-2 Installation GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Installation 2. Place or Mount the Equipment The Switch may be placed on a flat surface and stacked or mounted in a 19” EIArack. The Switch comes physically configured for placing on a flat surface. ...
Page 31 - Figure 2-2 Cabinet Mounting Bracket
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Installation 2-3 Installation Philips-head screws, one in each hole in the Side Fillers. c. Mount the Brackets. Refer to Figure 2-2. The Switch is shipped with apackage containing cabinet mounting brackets and screws....
Page 35 - Refer to Appendix A in this manual for Switch power requirements.; Logic Power Good LED
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Installation 2-7 Installation Refer to Appendix A in this manual for Switch power requirements. a. Connect the power cable to the back of the chassis. b. Connect the other end of the power cable to a 3 wire, grounded,...
Page 36 - Step 7 unless the POST passed.; Cable N or NL_Port Adapters to the Switch
2-8 Installation GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Step 7 unless the POST passed. 7. Cable N or NL_Port Adapters to the Switch Ports All 16 ports on the Switch may connect to N_Ports. Ports 1, 2, 5, 6, 9, 10, 13, and14 may connect to NL_Ports or N_Po...
Page 40 - Operating the Switch; The Switch becomes operational when:
2-12 Installation GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Operating the Switch The Continuous Test button on the front of the Switch chassis and the switches onthe Chassis Switch Panel on the back of the Switch chassis are the onlyoperational controls. Pla...
Page 41 - Section 3; Introduction; GigWorks MKII Switch Utilities; The GigWorks MKII Switch Utilities allows you to:
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-1 Section 3 Switch Management Introduction The Switch supports management through: • the Windows NT™ or Windows 95™-based GigWorks MKII SwitchUtilities, • a Trivial File Transfer Protocol (TFTP) se...
Page 44 - Figure 3-1 Ethernet Connection; Connection; Ethernet Cabling
3-4 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Ethernet Cabling The Switch is managed through the use of a customer-supplied managementstation connected to the Switch via 10BASE-T Ethernet. Figure 3-1 shows the location of the Switch Managem...
Page 45 - Configuring the Switch Ethernet Port; Configuring the Ethernet Port Using the Switch Utilities
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-5 Configuring the Switch Ethernet Port Configuring the Switch Ethernet Port Before the Switch can be managed using the Ethernet port, several managementparameters must be set correctly. At a minimu...
Page 46 - Configuring Multiple Switches; To configure the Switch chassis:
3-6 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual IP Address. When all parameters have been set correctly, click the SetParameters Button to set the values on the Switch chassis. The new valueswill be saved on the Switch, and will take effect w...
Page 47 - Managing the Switch Using the GigWorks MKII Switch Utilities; Loading the Switch Utilities; Set the Power Switch on the PC to ON.; Getting Started
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-7 Managing the Switch Using the GigWorks MKII Switch Utilities Managing the Switch Using the GigWorks MKII Switch Utilities The Switch Utilities allow you to manage the Switch through its Etherneti...
Page 48 - Switch Utilities; Each tab is supported by the File and Help menus.
3-8 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Switch Utilities Switches come configured from the factory with the default address10.0.0.1.) 3. Use the Setup Tab to read the UART statistics to make sure the Utilities canconnect to the Switch...
Page 50 - Switch Utilities — Management Information
3-10 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Switch Utilities — Management Information Management Information Figure 3-2 Management Information Tab Refer to Figure 3-2. The Management Information tab enables you to display allthe managed ...
Page 53 - Switch Utilities — Flash; Figure 3-3 Flash Tab; Flash File Name
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-13 Switch Utilities — Flash Flash Figure 3-3 Flash Tab Refer to Figure 3-3. The Flash tab enables you to load new control code into theSwitch’s Flash memory and also to command the Switch to perfor...
Page 55 - Switch Utilities — Versions; Figure 3-4 Versions Tab; World Wide Name; This number is the unique number of the Switch chassis.; Version Information
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-15 Switch Utilities — Versions Versions Figure 3-4 Versions Tab Refer to Figure 3-4. The Version tab enables you to display and log the Switchhardware and software version numbers. For a 16-port Sw...
Page 56 - Stage Number: In a single-stage Switch this number is not used.; Switch on Front
3-16 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Switch Utilities — Versions memory. This number is loaded as part of the Flash code. Therefore, this numbercould change following a Flash load. Prom Software Version: This is the version number...
Page 57 - Switch Utilities — Diagnostics Trace; Use File>Save to save the Display to a file.
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-17 Switch Utilities — Diagnostics Trace Diagnostics Trace Diagnostics Trace Overview The Diagnostics Trace tab allows Ancor service personnel to follow the progressof selected operations as they pr...
Page 58 - Controls are divided into two groups, Enables and Display.; Enables Radio Button
3-18 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Switch Utilities — Diagnostics Trace Figure 3-5 Diagnostics Trace Tab (Enables) Controls are divided into two groups, Enables and Display. Diagnostics Enable Controls Refer to Figure 3-5. The E...
Page 59 - Press to erase the Switch’s Diagnostics Trace Buffer.; Enables Information Display Window
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-19 Switch Utilities — Diagnostics Trace Enables None Button Deselect (remove the highlight from) all Diagnostics Trace functions. You maydeselect Diagnostics Trace functions one at a time by checki...
Page 61 - Switch Utilities — Setup; Figure 3-7 Setup Tab; Ethernet Port Radio Button
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-21 Switch Utilities — Setup Setup Figure 3-7 Setup Tab Refer to Figure 3-7. The Setup tab enables you to set up the connection betweenthe Ethernet port on the PC and the Ethernet port on the Switch...
Page 62 - The UART Stats Clear button resets the UART Statistics Counters.
3-22 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Switch Utilities — Setup UDP Port # Box This is the UDP Port Number the Utilities application uses to communicate with theproper application in the Switch. The default port number is 5000. Use ...
Page 63 - Switch Utilities — Chassis Configuration; Figure 3-8 Chassis Configuration Tab; Fabric ID; Press the Apply button to apply the Fabric ID to the chassis.; Chassis Number
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-23 Switch Utilities — Chassis Configuration Chassis Configuration Figure 3-8 Chassis Configuration Tab Refer to Figure 3-8. The Chassis Configuration tab enables you to assign ormodify the Fabric I...
Page 64 - both numbered beginning with 00.; Stage Type Radio Buttons
3-24 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Switch Utilities — Chassis Configuration both numbered beginning with 00. Press the Apply button to apply the Chassis Number to the chassis. Stage Type Radio Buttons Any MKII Switch chassis can...
Page 66 - Switch Utilities — Port Status; Figure 3-9 Port Status Tab
3-26 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Switch Utilities — Port Status Port Status Figure 3-9 Port Status Tab Refer to Figure 3-9. The Port Status tab enables you to find the status of all portson the Switch and any connected Loop de...
Page 69 - Switch Utilities — Zoning; Figure 3-10 Zoning Tab
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-29 Switch Utilities — Zoning Zoning Figure 3-10 Zoning Tab Zoning allows the user to divide the fabric ports into zones for more efficient and securecommunication among functionally grouped nodes. ...
Page 71 - A Broadcast Zone is only valid if it is enabled; A Name Server Zone is only valid if it is enabled.
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-31 Switch Utilities — Zoning Broadcast Zone Rules: 1. A Broadcast Zone is only valid if it is enabled 2. If Broadcast Zones are used on a Single Stage Switch in-which Hard Zonesare defined, the Bro...
Page 72 - Press the Apply Changes Button to put the changes into effect.
3-32 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Switch Utilities — Zoning 6. All ports not defined as being part of any enabled Name Server Zone areName Server Zone Orphans. Name Server Zone Orphans are all placed inthe same Name Server Orph...
Page 74 - Switch Utilities — Name Server; Figure 3-11 Name Server Tab; Port Field: This field contains the Switch port number.
3-34 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Switch Utilities — Name Server Name Server Figure 3-11 Name Server Tab Refer to Figure 3-11. The Name Server tab enables you to poll the Switch forName Server information. When you open this ta...
Page 76 - Switch Utilities — Management Configuration; Figure 3-12 Management Configuration Tab
3-36 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Switch Utilities — Management Configuration Management Configuration Figure 3-12 Management Configuration Tab Refer to Figure 3-12. The Management Configuration tab enables you toconfigure the ...
Page 78 - private; . You may modify this field by moving your cursor to the field and; public; . You may modify this field by moving your cursor to the field and
3-38 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Switch Utilities — Management Configuration moving your cursor to the field and typing. You may write the contents of thisfield to the Switch by pressing the Set SNMP Config. Button. Contact: U...
Page 80 - Managing the Switch Using TFTP; Retrieving the Current Switch Management Configuration File (; To retrieve the Switch configuration file:
3-40 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Managing the Switch Using TFTP Managing the Switch Using TFTP The firmware in the Switch can be upgraded using the Trivial File TransferProtocol (TFTP). This is a standard utility included in m...
Page 81 - snmpReadCommunity=public; Transfer a New Management Configuration File to the Switch:; To transfer the Switch configuration file to the Switch:
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-41 Managing the Switch Using TFTP gateway=0.0.0.0 arpTimeout=30000 snmpReadCommunity=public snmpWriteCommunity=private snmpTrapCommunity=public snmpName= snmpContact= snmpLocation= snmpDoAuthTrap=N...
Page 83 - default value for this parameter is the empty string, “”.; Loading New Switch Control Code into Flash:; To load a new I/O processor flash into the Switch:
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-43 Managing the Switch Using TFTP default value for this parameter is the empty string, “”. snmpLocation The value of the SNMP Systems Group SysName variable. This is usually set to identify the ph...
Page 84 - To load a new management interface flash into the Switch:
3-44 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Managing the Switch Using TFTP If the Switch load process fails for any reason, the Switch control code saved inthe Switch flash is not valid and must be reloaded. If the Switch is reset with a...
Page 86 - To test TFTP file transfers to the Switch:
3-46 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Managing the Switch Using TFTP Test the Switch File Transfer Process: (16-Port Switch Only) The file named test on the Switch can be used to test TFTP file transfers. Thisfile is not used by an...
Page 87 - To retrieve the index of valid Switch file names:
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-47 Managing the Switch Using TFTP Retrieving the Index of Valid Switch File Names: The Switch contains a file called index which lists the valid file names, their filetype (binary or text), and the...
Page 88 - Managing the Switch Using SNMP; Network Management
3-48 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Managing the Switch Using SNMP Managing the Switch Using the Simple Network Management Protocol (SNMP) Network management is the process of planning, organizing, and controlling acommunications...
Page 89 - Figure 3-13. Network Management Framework; The Network Management Station; Managing Nodes
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-49 Managing the Switch Using SNMP Figure 3-13 illustrates the four main components involved in network management. Figure 3-13. Network Management Framework The Network Management Station A network...
Page 91 - Access
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-51 Managing the Switch Using SNMP object identifier, or NULL. NULLs act as place holders reserved for future use. Access This property indicates the level of access to this particular object. Legal...
Page 92 - specific. The Ancor MKII Accounting MIB is an enterprise MIB.; The Simple Network Management Protocol; Polling-Only Data Collection
3-52 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Managing the Switch Using SNMP specific. The Ancor MKII Accounting MIB is an enterprise MIB. The Simple Network Management Protocol SNMP is a well-defined, public standard that is widely used b...
Page 93 - Figure 3-14 Polling-Only Data Collection; Interrupt-Based Data Collection; Figure 3-15 Interrupt-Based Data Collection; Trap-Directed Polling Data Collection
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-53 Managing the Switch Using SNMP Figure 3-14 Polling-Only Data Collection Interrupt-Based Data Collection This method provides immediate notification to the network management stationif an extraor...
Page 94 - Figure 3-16 Trap-Directed Polling Data Collection; Community Type; Control Community
3-54 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Managing the Switch Using SNMP or graphical representation allowing the administrator to easily diagnose andmanage the nodes and network traffic. Additionally, agents in the managed nodes can r...
Page 95 - Trap Community; File Name; set
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-55 Managing the Switch Using SNMP Trap Community This name needs to accompany trap messages. If it does not match the name setting on the network management station that receives the traps, the tra...
Page 96 - Each group has one or more tables associated with it.; Configuration Group Tables
3-56 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Managing the Switch Using SNMP Management Information Base (MIB) Switch MIB objects consist of 8 functional groups. These groups are: • system — MIB II Systems Group • interface — MIB II Interf...
Page 97 - Configuring SNMP; snmpReadCommunity
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Switch Management 3-57 Managing the Switch Using SNMP switch element • fcFeModuleTable — Module Table — a table of information about eachmodule in the switch element • fcFPortConfigTable — Port Configuration Table — a...
Page 98 - snmpContact
3-58 Switch Management GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Managing the Switch Using SNMP usually identical to the host name, for example, “switch001”. The default value for this parameter is the empty string, “”. snmpContact The value of the SNMP Syst...
Page 99 - Section 4; Section 4 contains information to help you find problems.; Power Supply Troubleshooting
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Diagnostics/Troubleshooting 4-1 Section 4 Diagnostics/Troubleshooting Introduction Section 4 contains information to help you find problems. Power Supply Troubleshooting helps you solve AC power and Power Supplyproble...
Page 100 - Power Supply/Fan Troubleshooting
4-2 Diagnostics/Troubleshooting GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Table 4-1 Troubleshooting Matrix (Single Power Supply) ON - OK AC sourcedisruption Power Supplyvoltage out ofrange Power Supplyoverheat Fan Failure ChassisOverheat System Status Front ...
Page 103 - Overview; Figure 4-1 Chassis Switch Panel
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Diagnostics/Troubleshooting 4-5 Power-On-Self-Test (POST) Power-On-Self-Test (POST) Overview The Switch checks the state of the Mode switches as part of its power-upprocedure. Refer to Figure 4-1 for the location of t...
Page 105 - Heartbeat LED Blink Patterns; Test/Failure Descriptions; Repeat pattern
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Diagnostics/Troubleshooting 4-7 Power-On-Self-Test (POST) The POST diagnostic program performs the following basic tests: • checksum tests on the Boot firmware located in a PROM and the mainSwitch firmware located in ...
Page 110 - Figure 4-2 Continuous Test Button; Continuous Test
4-12 Diagnostics/Troubleshooting GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Continuous Test Overview The Continuous Test button (when set to the TST position) causes the Switch togo from normal operate mode to continuous test mode. Refer to Figure 3-2. Figure...
Page 111 - Procedure
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Diagnostics/Troubleshooting 4-13 For example: • If the only problem with the Switch is one or more bad GBICs, the POSTtests will not detect the problem at power-up because they do not test theGBICs. The Continuous Tes...
Page 112 - Press the Continuous Test button to place the Switch back in its
4-14 Diagnostics/Troubleshooting GigWorks MkII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual b. If the Heartbeat LED is blinking an error code of eight (8), there is aproblem with one or more GBICs. 1. Press the Continuous Test button to place the Switch back in its normal op...
Page 113 - Fiber Continuity Tests; Did this correct the problem?; Yes Replace the faulty cable.; Did light shine through each fiber?; Replace the faulty cable.; Fiber Continuity Test
GigWorks MkII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Diagnostics/Troubleshooting 4-15 Fiber Continuity Tests When there is a problem communicating over a particular fiber link and both theSwitch and the N_Port adapter pass their respective tests, check the continuity of...
Page 115 - Section 5; Removal; Unplug the AC Power Cable from the back of the Switch chassis.; Fuse Holder
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Removal/Replacement Procedures 5-1 Section 5 Removal/Replacement Procedures Introduction The only Field Replaceable Units (FRUs) in the Switch are Input Fuses, GBICs,and the Power Supply(s). Input Fuse Removal 1. Unpl...
Page 116 - Input Fuse; Plug the AC Power Cable into the AC Power Plug Assembly.
5-2 Removal/Replacement Procedures GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Input Fuse Replacement 1. Insert the Fuse(s) into the Fuse Holder. Refer to the Reference Informationappendix for fuse-type information. 2. Insert the Fuse Holder into the right sid...
Page 117 - GBIC; GBIC
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Removal/Replacement Procedures 5-3 GBIC GBICs may be removed and replaced with the power on and the Switch operatingwithout disrupting traffic on other ports. Removal 1. Disconnect the cable (if one is connected) from...
Page 118 - Removing GBICs that have bail-operated latches.
5-4 Removal/Replacement Procedures GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual GBIC 2b. Removing GBICs that have bail-operated latches. Some GBICs have latches that are operated by a built-in bail as representedin the drawing below. You simply use your finger-...
Page 120 - Power Supply
5-6 Removal/Replacement Procedures GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Power Supply Power Supply Removal If the Switch contains two Power Supplies, either supply is “Hot-Pluggable”.That is, one supply can be removed while the Switch is powered-up and o...
Page 121 - Replacement
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Removal/Replacement Procedures 5-7 Replacement If the Switch contains two Power Supplies, either supply is “Hot-Pluggable”.That is, one supply can be replaced while the Switch is powered-up and operatingas long as the...
Page 123 - Appendix A; Switch; Fibre Channel Classes of Service:
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Reference Information A-1 Appendix A Reference Information Appendix A contains the specifications for the GigWorks MKII-16 Switch ModelMKII-BASE16. Refer to the Switch Overview in Section 1 for the location of allconn...
Page 124 - Number of Fibre Channel Ports:
A-2 Reference Information GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Reference Information FL_Port Characteristics: .............. Each FL_Port can support 1-126 NL_PortsEach public loop can handle both public andprivate loop transactions Number of Fibre Chan...
Page 125 - Does not require system interruption for:; LED indicators, Chassis Switch panel
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Reference Information A-3 Reference Information Gb/s, even though backplanes supply up to 32 Gb/s. Maximum Frame Sizes: ............. Model MKII-BASE16 — 2148 bytes (2112- byte payload) for all classes of service supp...
Page 126 - The chassis; MUST be supported by a shelf; or rails when rack-mounted
A-4 Reference Information GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Reference Information Switch Agent : ........................... Allows a network management station to obtain configuration values, traffic information, and failure data pertaining to the F...
Page 127 - Cooling air flows from the front to the back.
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Reference Information A-5 Reference Information Switch Environmental Operational Temperature: ............ 10 to 40°C (50 to 104°F) Operating Humidity: ................... 25 to 80%, non-condensing Operating Altitude:...
Page 128 - Duplex SC
A-6 Reference Information GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Reference Information Shortwave Laser GBIC (multi-mode) Connector: ................................... Duplex SC Color coding: ............................... Beige or black exposed connecto...
Page 130 - Front View; Figure A-1 GigWorks MKII-16 Switch Model MKII-BASE16 Dimensions
A-8 Reference Information GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Reference Information 2.362 (.093") 475.437 (18.718") 480.16 (18.904") Front View Back View Dimensions in mm (inches) 447.04 (17.6") 2.39 (.094") 8x7.92 (.312") 12.31...
Page 133 - Appendix B; Help Desk
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Ancor Customer Service B-1 Appendix B Ancor Customer Service Appendix B contains information about Ancor Customer Service. Ancor Customer Service Ancor offers several service programs including Basic Warranty service:...
Page 134 - Ancor will attempt to isolate and verify the reported problem.; Customer Responsibilities; Implement proper backup procedures.
B-2 Ancor Customer Service GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Ancor Customer Service Software Support Ancor actively supports the current software/firmware release and the priorrelease for 6 months following the general availability date for the curre...
Page 135 - Appendix C; Figure C-1 Chassis Switch Panel
GigWorks MKII16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Chassis Switch Panel C-1 Appendix C Chassis Switch Panel Chassis Switch Panel Refer to Figure C-1 for the location of the Chassis Switch Panel. The ChassisSwitch panel contains a microprocessor Reset button, switches f...
Page 136 - Figure C-2 Reset Button; Force PROM Mode; Figure C-3 Force PROM and Watch Dog Configuration Switches; FP; RESET
C-2 Chassis Switch Panel GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Chassis Switch Panel Reset Refer to Figure C-2. Figure C-2 Reset Button Use the Reset button only under the direction of your service representative. Force PROM Mode There may be circumstance...
Page 137 - Refer to Figure C-4. The switches are shown in the 00 position.; Test Mode; Utility mode. This Test Mode is for factory use only.; MODE
GigWorks MKII-16 Switch Model MKII-BASE16Installer's/User's Manual 59003-01 Rev. A Chassis Switch Panel C-3 Chassis Switch Panel Watch Dog Timer Disable Refer to Figure C-3. The Switch contains a Watchdog timer that resets theinternal processor in the event of a hangup. The Watchdog Disable switch, ...
Page 138 - CHASSIS
C-4 Chassis Switch Panel GigWorks MKII-16 Switch Model MKII-BASE16 59003-01 Rev. A Installer's/User's Manual Chassis Switch Panel Chassis #, Fabric #, Stage #, and Area # Configuration Switches The Chassis #, Fabric #, Stage #, and Area # configuration switches (shown inFigure C-5) are not used. Fig...