Page 3 - Contents; Figures
Operations Manual (OM700-02) i Contents Planar D6015TM Series Medical Monitor ........................................................ 1 Functional Description .................................................................................................1Product Features ............................
Page 4 - ii
ii Operations Manual (OM700-02) Figure 1: Controls and Front View ..............................................................................7 Figure 2: Monitor, Rear Ports ......................................................................................8 Figure 3: Connecting the Optional To...
Page 5 - Planar D6015TM Series Medical Monitor; Functional Description
Operations Manual (OM700-02) 1 Planar D6015TM Series Medical Monitor The Planar D6015TM Series Medical Monitor is a 15-inch XGA monitordesigned to be versatile, ergonomic, and easy to use. It is capable of displayingmost video standards from 640x480 (VGA) to 1024x768 (XGA). The digitalcontrols locat...
Page 6 - Product Features; Cleaning Instructions
2 Operations Manual (OM700-02) Product Features • Display Type: Color Active Matrix LCD • Control Buttons: − Function select up and Function select down ( and ) − Adjustment increase and Adjustment decrease ( and ) − Power on/off ( ) • Adjust speaker volume directly with the Adjustment increase/decr...
Page 7 - Safety Instructions; Caution: AC Adapter must be plugged into a GROUNDED power outlet.; Disposal Information
Operations Manual (OM700-02) 3 Safety Instructions • Do not place your monitor near a window. Exposing the monitor to rain, water,moisture, or constant direct sunlight can severely damage it. • Do not place anything on top of the monitor-to-computer signal cord. Make sure thecord is placed in an are...
Page 8 - Symbol Explanations; Tested to comply with FCC Class B standards.; Regulatory Compliance
4 Operations Manual (OM700-02) Symbol Explanations Following are explanations of the symbols found on the monitor or power supply. Indicates proof of conformity to applicable European EconomicCommunity Council directives and to harmonized standardspublished in the official journal of the European Co...
Page 9 - EU Declaration of Conformity for Medical Applications
Operations Manual (OM700-02) 5 classified according to Rule 12 as an MDD Class I device – component or accessory. The MDDsets out that manufacturers of Class I medical devices or accessories shall satisfy therequirements in regards to design and manufacturing controls, i.e. the applicable assessment...
Page 10 - Installation; AC adapter with cable. (CAUTION: AC Adapter must be plugged into a
6 Operations Manual (OM700-02) Installation Before you unpack your monitor, prepare a suitable workspace. You need astable and level surface near a grounded wall outlet in an area which is relativelyfree of glare from sunlight or other sources of bright light. The monitor is cooledby natural convect...
Page 11 - Identifying Components; Front View; The monitor stand supports the monitor for use on a desktop.
Operations Manual (OM700-02) 7 Identifying Components Front View Figure 1: Controls and Front View 1. Monitor Screen The screen is capable of producing most display standards from 640 x 480 VGAto 1024 x 768 XGA. A VESA mounting plate (not shown) is secured to the rearof the monitor and is compatible...
Page 12 - Rear View; VGA Cable; Connect the low-voltage cable from the power adapter to this port.; -Pin D-Sub Connector for Optional Touchscreen; When headphones are plugged in, the stereo speakers are disabled.
8 Operations Manual (OM700-02) 5 4 3 2 1 Rear View Figure 2: Monitor, Rear Ports 1. VGA Cable This 1.5 meter (5 ft.) cable has a 15-pin D-Sub VGA connector used toconnect to your computer’s VGA port. 2. Power Input Port (locking/latching mini-Din 4-Pin) Connect the low-voltage cable from the power a...
Page 13 - Connecting the Optional Touchscreen; Note; : Please contact your system provider or ELO TouchSystems at; Positioning
Operations Manual (OM700-02) 9 Connecting the Optional Touchscreen If your monitor has this optional feature, connect the monitor’s 9-pin D-subserial port to your computer’s 9-pin RS232 serial port using the cable whichcame with the optional touchscreen package. Figure 3: Connecting the Optional Tou...
Page 14 - Adjusting the Viewing Angle; to; Do not force the monitor past its maximum extension in either; Connecting AC Power
10 Operations Manual (OM700-02) Adjusting the Viewing Angle The Planar D6015TM Series Medical Monitor was designed to allow adjustmentto a comfortable viewing angle. The monitor’s angle settings range from -5 ° to +25 ° on the optional desk stand (Figure 4). Figure 4: Screen Angle Settings Caution: ...
Page 15 - Connecting Video; Connecting Optional Stereo Speakers; Planar does not recommend using the audio from the monitor as
Operations Manual (OM700-02) 11 Connecting Video With the power to your computer and the monitor off, connect the supplied videocable from the monitor to the computer’s VGA port (Figure 6). Figure 6: Connecting the Monitor to Your System Make sure the VGA cable connector is securely connected to the...
Page 16 - Power Management System
12 Operations Manual (OM700-02) Power Management System The Planar D6015TM Series Medical Monitor complies with the VESA DPMSpower management proposal. The VESA DPMS proposal provides four phasesof power-saving modes by detecting the horizontal or vertical sync signal asshown in the table below. Mod...
Page 17 - The Display Controls; Function select up
Operations Manual (OM700-02) 13 The Display Controls Located on the front of the Planar D6015TM Series Medical Monitor are fivebuttons for operating the monitor and accessing the functions on the On-ScreenDisplay (OSD). Button 1. Function select up 2. Function select down 3. Adjustment increase 4. A...
Page 18 - Adjusting the Medical Monitor’s Display; buttons ( and ) to advance to the next sub-menu and make; On-Screen Display Lockout
14 Operations Manual (OM700-02) Adjusting the Medical Monitor’s Display Using the monitor’s On-Screen Display (OSD), you can adjust the contrast,brightness, display position, display clarity, and color temperature of the display.You can also adjust the stereo speaker volume and set OSD parameters. A...
Page 19 - OSD Main Menu; buttons; Main Menu; Basic Setting
Operations Manual (OM700-02) 15 OSD Main Menu To access the OSD Main Menu, briefly press the Power button (see Figure 8).The following screen appears: MAIN MENU BASIC SETTINGPOSITION AUTO-ADJUST COLOR TEMP.MISCELLANEOUSRESET ADJ KEY TO START Figure 10: The OSD Main Menu The control functions are gro...
Page 22 - Technical Information; Planar D6015TM Series Medical Monitor Specifications
18 Operations Manual (OM700-02) Technical Information Planar D6015TM Series Medical Monitor Specifications Display Panel 15-inch (381 mm) XGA active matrix LCD (AMLCD) Display Colors 262,144 Dimensions: w/bracket w/desk stand 408 x 333 x 85 mm (W x H x D)408 x 387 x 175 mm (W x H x D) Weight: w/brac...
Page 23 - Video Modes
Operations Manual (OM700-02) 19 Video Modes The Planar D6015TM Medical Monitor will support 25 video timing modeswhich were preset at the factory. Those modes not supported will cause themonitor to go into power-saving mode. Once a mode is optimized, there is noneed to make any further adjustment as...
Page 24 - Connectors; DC Input
20 Operations Manual (OM700-02) Connectors DC Input Locking or latching 4-pin Mini DIN Receptacle. The vendor P/N is H.C.E.MD00027 or equivalent. Description Pin Pin Description +12VDC 1 3 +12VDC GND 2 4 GND Shield Shield Video Input 15 pin D-subminiature connector. The vendor P/N is Aces 85314-1500...
Page 25 - Mechanical Outline Drawings
Operations Manual (OM700-02) 21 Mechanical Outline Drawings All dimensions shown in the following drawings are specified in millimeters. Figure 11: GCX/VESA Mounting Option
Page 27 - Troubleshooting Procedures; PROBLEM: No Signal Coming; PROBLEM: Display is Unclear and Unstable
Operations Manual (OM700-02) 23 Troubleshooting Procedures The Planar D6015TM Series Medical Monitor was factory adjusted to standardVGA timing. Due to output timing differences among various VGA cards, youmay initially experience an unstable or unclear display when a new display modeor new VGA card...
Page 28 - PROBLEM: Signal Over Supported Range; Pan the display picture with the Function; PROBLEM: There is No LCD Display
24 Operations Manual (OM700-02) PROBLEM: Signal Over Supported Range When the signal is out of the monitor’s frequency range, the screen display willnot be centered and the following message will be displayed: SIGNAL OVER RANGE! PRESS FUN/ADJ KEY FUN → H-POSITION ADJ → V-POSITION Pan the display pic...
Page 29 - Description of Warranty; Commencement and Duration of Warranty
Operations Manual (OM700-02) 25 Description of Warranty Planar Systems (Planar) warrants that the goods sold hereunder will be free ofdefects in materials and workmanship, and such goods will substantially conformto the specifications furnished by Planar, and to any drawings or specificationsfurnish...
Page 30 - disinfected before returning to Planar for; . Any product not cleaned prior to shipment; will be returned to the; Returns will not be accepted without an assigned RMA number.
26 Operations Manual (OM700-02) The warranty set forth above shall not be enlarged, diminished or affected by,and no obligation or liability shall arise from Planar, any authorized dealer orany other person's rendering of technical advice, assistance or services inconnection with the buyer's order o...
Page 31 - Ordering Information
Operations Manual (OM700-02) 27 Ordering Information Product Part Number D6015TM 15-Inch XGA Medical MonitorD6015TM 15-Inch XGA Medical Monitor, w/deskstandD6015TM;TS 15-Inch XGA Medical Monitor, SAW TouchscreenD6015TM;TS 15-Inch XGA Medical Monitor, SAW, w/deskstandD6015TM;TR 15-Inch XGA Medical Mo...