Table of Contents:
- Page 2 – This green indicator shows the control is turned on.; Heat Demand Indicator:; BACKUP; FLAT BOTTOM
- Page 3 – Turn the appliance ON:; Place the melt switch in the desired position, typically Melt; To turn the appliance OFF:; Start with control in the OFF condition.; Drain Valve Interlock:; Close the drain valve.
- Page 4 – High Limit device is tripped and needs to be reset.; Open or Shorted Probe:; This condition requires repair of the probe, or related wiring.; Field Calibration
L20-314 Rev 0 (9/7/07)
English
This control was developed by Pitco to replace bulb and capillary thermostats in fryer
applications. It utilizes the latest in microprocessor technology and allows a host of features
not practical with a simple capillary t-stat. Features include a selectable start up melt cycle,
drain valve interlock, faulty probe detection, and a boil out mode.
This manual details the operation and adjustment of the Solid State Temperature Control.
IMPORTANT INFORMATION FOR FUTURE REFERENCE
Record the following information from the appliance ID plate
and retain this manual for the life of the equipment:
Model #: __________________________
Serial #: __________________________
Date Purchased: ___________________
Operations Manual
Covering Pitco #
B2005301 SSTC Primary Control for GAS appliances
B2005302 SSTC Backup Control for GAS appliances
B2005303 SSTC Primary Control for Electric appliances
B2005304 SSTC Backup Control for Electric appliances
B2005305 SSTC Backup Control for SE147 Electric appliances
B2005401 SSTC Primary Control for Flat Bottom GAS appliances
Solid State Temperature Control
PRIMARY
BACKUP
FLAT BOTTOM
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Solid State Temperature Control (SSTC) L20-314 Rev 0 (9/7/07) Page 2 1 Switch and Indicator Locations and Function: On / Off switch: Turns the control on or off. The power indicator will be illuminated when the switch is in the onposition. Primary / Backup select switch: In appliances with primary A...
Solid State Temperature Control (SSTC) Page 3 L20-314 (9/7/07) 2 Operation: 2.1 Turn the appliance ON: Place the melt switch in the desired position, typically Melt . No melt may also be selected only if vat is filled with liquid cooking oil. Turn the control ON bypressing the rocker switch to the “...
Solid State Temperature Control (SSTC) L20-314 (9/7/07) Page 4 3 Fault Detection 3.1 High Limit Trip or “Heat Failure”: This control monitors the appliance response to heat demand signals.Under normal conditions the heat feed back indicator follows the heatdemand indicator. When the appliance fails ...