Page 2 - CAUTION
WARNING: TO P R E V E N T F I R E O R E L E C T R I C S H O C K H A Z A R D , D O N O T E X P O S E T H I S A P P L I A N C E T O R A I N O R M O I S T U R E . The serial number of this product may be found on the topof the unit.You should note the serial number of this unit in the spaceprovided and...
Page 3 - CONTENTS; ENGLISH
CONTENTS PREFACE ........................................................................................................................................................................ 2FEATURES ...........................................................................................................
Page 4 - by use of Electronic Light Control (ELC) function; PREFACE; Selectable auto iris control signal for the lens from
-2- 1. The following functions are built-in. (1) Auto Light Control (ALC)/Electronic Light Control (ELC) (2) Back Light Compensation (ON: Photometric weight is given to the center of thescreen/OFF: Effective if the object is not in thecenter of the screen) (3) Various External Sync Functions, includ...
Page 5 - PRECAUTIONS
-3- 1. Do not attempt to disassemble the camera. To prevent electric shock, do not remove screwsor covers.There are no user serviceable parts inside. Ask aqualified service person for servicing. 2. Handle the camera with care. Do not abuse the camera. Avoid striking, shaking,etc. The camera could be...
Page 6 - MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
-4- MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS WV- BP330 VIDEO OUT GEN-LOCK L INTAGC ONALCBLC ONVIDEOG/L 75 VIDEOLEVEL V. PHASE H Ω LL OFFELCOFF DC Hi-Z GND AC 24V IN 1 2 VIDEO OUT GEN-LOCK L INTAGC ONALCBLC ONVIDEOG/L 75 VIDEOLEVEL V. PHASE H Ω LL OFFELCOFF DC Hi-Z DC 12V IN VIDEO OUT GEN-LOCK L ...
Page 9 - To prevent fire or electric shock hazard,
-7- Cautions: 1. Connect to 12V DC (10.5V-16V) or 24V AC (19.5V-28V) class 2 power supply only.Make sure to connect the grounding leadto the GND terminal when the power issupplied from a 24V AC power source. 2. To prevent fire or electric shock hazard, use a UL listed wire VW-1, style 1007 cablefor ...
Page 10 - CONNECTIONS; • Calculation of maximum cable length between
-8- CONNECTIONS A. WV-BP330 (120V AC 60Hz) Connect the power cord to an electrical outlet of120V AC 60Hz. B. WV-BP332 (12V DC) Connect the power cord to the DC 12V IN terminalon the rear panel of the WV-BP332. 12 V DC(10.5 V - 16 V) Copper wire #24 #22 #20 #18 size (AWG) (0.22mm 2 ) (0.33mm 2 ) (0.5...
Page 11 - Video Cable
-9- C. The maximum extensible coaxial cablelength between the camera and the monitor isshown below. Video Cable 1. It is recommended to use a monitor whose resolu- tion is at least equal to that of the camera. 2. Set the termination switch to the 75 Ω position on the last monitor. A. Use a 75 Ω coax...
Page 13 - Installation of Auto Iris Lens Connector; (1) Cut the iris control cable at the edge of the lens; When the iris control cable is too thick to
-11- Installation of Auto Iris Lens Connector Install the lens connector (YFE4191J100) when using avideo drive ALC lens. The installation should be made by qualified ser-vice personnel or system installers. (1) Cut the iris control cable at the edge of the lens connector to remove the existing lens ...
Page 14 - Caution for Mounting the Lens; Mounting the Lens; Mount the lens by turning it clockwise on the lens
-12- Caution for Mounting the Lens The lens mount should be a C-mount or CS-mount (1”-32UN) and the lens weight should be less than 450 g (0.99 lbs). If the lens is heavier, both the lens and cam-era should be secured by using the supporter.The protrusion at the rear of the lens should be asshown be...
Page 15 - FOCUS OR FLANGE-BACK ADJUSTMENT
-13- The following adjustment should be made by qualifiedservice personnel or system installers. 1. Loosen the screws on the flange-back adjusting ring. 2. Turn the flange-back adjusting ring to the desired position. Caution: When the C-mount lens is mounted, do not rotate the ring counterclockwise ...
Page 16 - INSTALLATION OF CAMERA
-14- • Mounting from the bottom This camera is designed to be mounted from thebottom, as shown below. The mounting hole is astandard photographic pan-head screw size (1/4”- 20). • Mounting from the top Remove the mount adapter from the bottom of thecamera by removing the two fixing screws. Attachthe...
Page 17 - PREVENTION OF BLOOMING AND SMEAR
-15- When the camera is aimed at a bright light, such as aspot light, or a surface that reflects bright light, smearor blooming may appear. Therefore, the camerashould be operated carefully in the vicinity of extremelybright objects to avoid smear or blooming. , , , , , , Bright object Smear PREVENT...
Page 18 - SPECIFICATIONS
Pick-up Device: 768 (H) x 494 (V) pixels, Interline Transfer CCD Scanning Area: 4.9 (H) x 3.7 (V) mm (Equivalent to scanning area of 1/3” pick-up tube) Synchronization: Internal, External, Line-locked or Multiplexed vertical drive (VD2) selectable Scanning System: 2 : 1 interlace Scanning: 525 lines...
Page 19 - STANDARD ACCESSORIES
Dimensions (without lens): 67 (W) x 55 (H) x 123 (D) mm[2-5/8” (W) x 2-3/16” (H) x 4-13/16” (D)] Weights (without lens): WV-BP330: 0.62 kg (1.40lbs) WV-BP332: 0.445 kg (0.98lbs) WV-BP334: 0.470 kg (1.04lbs) Weights and dimensions indicated are approximate.Specifications are subject to change without...
Page 20 - Video Imaging Systems Company
N0398-1048 YWV8QA4916BN Printed in Japan N 30 Imprimé au Japon Video Imaging Systems Company A Division of Panasonic Broadcast & Television Systems CompanyA Unit of Matsushita Electric Corporation of America Executive Office: One Panasonic Way 4H-2, Secaucus, New Jersey 07094 Regional Offices:No...