This Installation Manual covers Panasonic’s ceiling radiation damper (model PC-RD05C5), designed to reduce radiant heat transfer in HVAC systems, particularly with Whisper-series fans. Key topics include mounting configurations–such as securing the damper to fan housings and ceiling structures–using UL-certified hardware for both non-combustible and combustible ceilings, and ensuring compatibility with specific wood truss designs. The manual emphasizes horizontal installation and highlights UL555C certification requirements across various fan models.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
Page: / 9

Table of Contents:

  • Page 1 – Damper Installation with Fan Mounting
  • Page 2 – Damper Installation with Whisper Fans
  • Page 3 – Mounting Brackets and Structural Compatibility
  • Page 4 – Non-combustible Ceiling Radiation Cover Installation
  • Page 5 – Radiant Ceiling Panel Mounting
  • Page 6 – Combustible Ceiling Radiation Cover Installation
  • Page 7 – Ceiling Register Attenuation Mounting
  • Page 8 – Radiation Attenuation Shutter Installation
  • Page 9 – Damper Mounting and Structural Certification
Loading the manual
Page 1

1. Position the ceiling radiation damper on the inlet side of the fan such that the holes in the damper mounting

flanges line up with the holes in the flange of the fan housing. Secure the damper to the fan housing using the four

#10-32 machine screws/nuts supplied.
2A. For a damper used with a fan requiring a plug connector to pass through the damper, secure the plug

connector using the wiring bracket and #8 course threaded screw supplied. (See Figure 2A) If the plug connector

cannot reach through the damper to the grill plug attachments, release the clips holding the wiring inside the fan

with a Phillips-Head screwdriver. make sure the wire lead or plug connector does not interfere with the closing of

the damper.
2B. For a damper used with a fan that does not require a plug connector, secure

the wiring bracket supplied to the damper frame using the supplied #8 course

threaded screw supplied. Make sure the wiring bracket covers the notch in the

frame. (See Figure 2B).
3. With the damper secured to the fan housing, the assembly can be attached to

the structure above using the holes in the fan housing flange or the supplied mounting brackets. If the mounting

brackets are used, position the mounting brackets under the damper mounting flanges or under the fan housing

flange as required. Position the slot so it aligns with the holes in the fan housing and/or the holes in the damper

mounting flanges (See Figure 3). If the damper/fan is being attached to the adjacent structure, the brackets must

be used and adjusted to fit accordingly. If the damper/fan is supported from structure above, the brackets should

be adjusted so the ends of the brackets align accordingly. Once the brackets are adjusted, attach them to the

flange of the fan housing using four #10-32 screws and nuts supplied. A minimum of two fasteners per side is

required.
4. The ceiling penetration should be located within ceiling tiles or panels without necessitating cuts in the ceiling suspension main runners or cross

tees. If required, a maximum of one runner or cross tee may be cut to enable proper damper location and installation. Each cut end shall be supported

by a min. 12 swg (2.7) vertical hanger wire. The opening in the ceiling should be the same size as the outside of

the damper frame.
5. Position the damper/fan assembly such that the bottom edge of the damper is flush with the finished surface of

the ceiling. Attach the damper/fan assembly to the structure above or adjacent to it. If the damper/fan is being

attached to the assembly above, a minimum of 12 swg. (2.7) hanger wire must be used. A minimum of two hanger

wires on two opposite sides are required. The hanger wires can be attached directly to the fan housing flange or to

the ends of the mounting brackets. If the damper/fan assembly is being directly mounted to the adjacent structure, a

minimum #8 (M4) sheet metal screws or 1/2" dia. bolts/nuts must be used. If necessary, a min. 1/2" wide flange is

to be attached to the damper using a minimum #8 (M4) sheet metal screw, 3/16" pop rivets, welds or bolts at 6"

(152) o.c. maximum. A minimum of 2 connections per side is required.
6. For other installation details see Panasonic Installation Instructions.

For horizontal mount only.
Certified to UL555C.

Up to 3 hour non-combustible assemblies

ceiling radiation damper

PC-RD05C5 installation instructions

N

on

-C

om

bu

st

ib

le

C

ei

lin

g

R

ad

ia

tio

n

D

am

pe

rs

P

C

-R

D

05

C

5

(1

/9

)

M

-5

44

47

-H

Information is correct at time of printing. However, we reserve the right to make changes without notice. Note: All dimensions are shown in () millimeters..

For fan model:

Plug

Connector

Wiring

Bracket

L I

S T I N G

S

E R V I C E

ST

AT

E O

F CAL IFOR

NIA

ST

AT

E FIR E M ARS H

A L

L

C

Fan Housing

Flange

Mounting

Brackets

Hanger Wire

Fan Housing

Damper

Mounting Bracket

Ceiling Tile

Figure 1A

Figure 1B

Figure 2A

Figure 2B

Figure 3

SEE DETAILS ON UL

CLASSIFICATION

MARKING ON

ENCLOSED PRODUCT

®

UL

CLASSIFIED

®

UL

CLASSIFIED

WhisperGreen DC: FV-1115VK2, FV-1115VKL2, FV-0511VK2, FV-0511VKSL2, FV-0511VKL2, FV-0511VKS2.
WhisperCeiling DC: FV-0511VQ1, FV-1115VQ1, FV-0511VQL1, FV-1115VQL1.
WhisperSense DC: FV-0511VQC1, FV-0511VQCL1.
WhisperFit DC: FV-0511VF1, FV-0511VFC1, FV-0511VFL1, FV-0511VFL1K.
WhisperValue DC: FV-0510VS1, FV-0810VSS1, FV-0510VSC1, FV-0510VSL1, FV-0810VSSL1, FV-0510VSCL1.

July 2021

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Panasonic
Model
FV 0511VK2
Document type
Manual
Language(s)
English, Spanish, French
Pages
9
File size
1.1 MB
Format
PDF

Other Manuals for Panasonic FV 0511VK2

Summary

Page 1 - Damper Installation with Fan Mounting

Installation instructions for mounting the PC-RD05C5 ceiling radiation damper, including component placement, wiring, securing to fan housing, and handling ceiling penetrations.

Page 2 - Damper Installation with Whisper Fans

Installation procedures for the PC-RD05C5 ceiling radiation damper when used with Whisper series fan models, detailing placement relative to ceiling components and wiring bracket installation.

Page 3 - Mounting Brackets and Structural Compatibility

Instructions for mounting brackets, securing the damper to the fan housing, installing drywall support assemblies, and specifying compatible UL-rated wood truss floor/ceiling designs. The product is certified for horizontal mounting only.