Panasonic 2008 - Manual
A user manual for Panasonic’s inverter-based wall-mounted split air conditioning systems highlights advanced technologies like the e-ion Air Purifying System with Patrol Sensor, which actively monitors and neutralizes airborne pollutants, bacteria, and mold through electrostatic filtration. The guide emphasizes energy-efficient operation via Hyper Wave Inverter technology, precise temperature control, and low-noise performance across various models, including those with specialized air purification features such as Supersonic Air Purifying Systems for allergen reduction. Key topics include system specifications (capacities, efficiency ratings), operational modes, maintenance access, and diagnostic capabilities to ensure reliable comfort and clean indoor air.
Table of Contents:
- Page 1 – Product Identification and Key Features
- Page 2 – Air Conditioner Performance Benefits
- Page 3 – Wall-Mounted Split AC Model Line-up
- Page 4 – e-ion Air Purifying System Mechanism
- Page 5 – Active e-ion Air Purification Process
- Page 6 – Patrol Sensor and Active e-ion Technology
- Page 7 – Mega e-ion Filter Performance
- Page 8 – Inverter Technology Explanation
- Page 9 – Advanced Inverter Features
- Page 10 – Single Inverter Split Unit Specifications
- Page 11 – Deluxe Wide Inverter Unit Specifications
- Page 12 – Supersonic Air Purification System
- Page 13 – Air Conditioner Model Comparison
- Page 14 – Split AC System Features and Nomenclature
- Page 15 – Advanced Operational Features and Certifications
- Page 16 – Detailed Technical Specifications
Specifications
• Power plugs are not supplied with the unit.
• Electrical work must be installed by a licensed electricians. Be sure to use the correct rating of the
power plug and mains circuit for the model to be installed.
• Please read the Installation Instructions carefully before installing the unit, and read the Operating
Instructions before using.
Power
Supply
27
°
C DB/19
°
C WB
20
°
C DB
35
°
C DB
7
°
C DB/6
°
C WB
Cooling
Inside air temperature
Outside air temperature
Heating
Rating Conditions
Single Split
*
1
Sound Pressure Level is measured according to JIS C 9612.
*
2
Additional Gas might be required for some models.
Power
Supply
W/W
Maximum
Pipe
Length
*
2
Model No.
CS-W7DKR
(CU-W7DKR)
CS-W9DKR
(CU-W9DKR)
CS-W12EKR
(CU-W12EKR)
CS-W18DKR
(CU-W18DKR)
CS-W24EKR
(CU-W24EKR)
7,840
9,380
12,300
18,100
24,000
2.30
2.75
3.60
5.30
7.03
L/h
1.5
1.6
2.1
2.9
4.0
Outdoor (Hi)
kg
9
(26)
9
(29)
8
(35)
11.0
(56.0)
11.0
(63.0)
mm
280 x 799 x 183
(510 x 650 x 230)
280 x 799 x 183
(510 x 650 x 230)
280 x 799 x 183
(540 x 780 x 289)
275 x 998 x 230
(750 x 875 x 345)
275 x 998 x 230
(750 x 875 x 345)
8,350
10,400
13,300
19,600
26,600
2.45
3.05
3.90
5.75
7.80
Cooling Capacity
Heating Capacity
Air Flow
Dehumid Running
Current
Power
Input
EER
COP
Sound Pressure
Level
*
1
dB (A)
Sound Power
Level dB
Net Weight
Dimensions
Height x Width x Depth
L/s
143
162
A
3.2
3.0
3.8
3.8
5.0
4.9
7.8
7.8
11.1
11.7
kW
0.72
0.685
0.875
0.865
1.1
1.09
1.81
1.80
2.37
2.46
3.19
3.58
3.14
3.53
3.27
3.58
2.93
3.19
2.97
3.17
Indoor
(Hi/Lo/S-Lo)
34/26/23
36/26/23
36/26/23
39/26/23
41/29/26
42/29/26
43/38/35
42/38/35
47/41/38
46/41/38
Outdoor (Hi)
47
49
49
50
50
50
50
51
53
54
132
152
63
64
62
64
64
65
65
66
66
67
Star
Rating
(50Hz/240V)
m
10
10
15
25
25
Indoor
Indoor
Indoor
Indoor
Indoor
178
182
255
267
290
303
5.0
6.0
4.5
5.5
4.5
4.5
4.0
3.5
3.5
3.0
Btu/h
kW
Single Inverter Split
Btu/h
kW
L/h
Outdoor(Hi)
A
kW
W/W
kg
mm
Indoor (Hi/Lo/S-Lo) Outdoor (Hi/S-Lo)
Cooling Capacity
Heating Capacity
Air Flow Dehumid Running
Current
Power
Input
EER
COP
Sound Pressure
Level
*
1
dB (A)
Sound Power
Level dB
Net Weight
Maximum
Pipe
Length
*
2
m
Dimensions
Height x Width x Depth
Model No.
(50Hz/240V)
L/s
Star
Rating
6.30
(0.90~7.10)
7.20
(0.90~8.50)
21,500
(3,070~24,200)
24,600
(3,070~29,000)
10
(51)
275 x 998 x 230
(750 x 875 x 345)
3.5
20
3.06
3.60
45 / 37 / 34
45 / 37 / 34
48 / 43
49 / 44
9.0
8.8
2.06
(0.215~2.40)
2.00
(0.245~2.70)
61
62
270
288
4.0
4.5
Outdoor
8.10
(0.90~8.60)
9.60
(0.90~11.00)
27,600
(3,070~29,300)
32,700
(3,070~37,500)
11
(63)
275 x 998 x 230
(795 x 900 x 320)
4.8
30
2.98
2.95
49 / 38 / 35
48 / 38 / 35
53 / 48
53 / 48
67
67
12.0
14.4
2.72
(0.35~2.95)
3.25
(0.36~3.79)
295
312
3.5
3.0
Outdoor
CS-E9GKR
(CU-E9GKR)
2.60
(0.80~3.00)
3.60
(0.80~5.00)
8,870
(2,730~10,200)
12,300
(2,730~17,100)
9
(34)
280 x 799 x 183
(540 x 780 x 289)
1.6
15
4.33
4.26
39 / 26 / 21
40 / 27 / 24
46 / —
47 / —
2.8
3.8
0.60
(0.175~0.78)
0.845
(0.165~1.36)
59
60
173
183
6.0
6.0
Outdoor
CS-E15GKR
(CU-E15GKR)
4.40
(0.90~5.00)
5.50
(0.90~7.10)
15,000
(3,070~17,100)
18,800
(3,070~24,200)
9
(47)
280 x 799 x 183
(750 x 875 x 345)
2.4
15
3.21
3.50
43 / 32 / 25
43 / 35 / 32
46 / 41
46 / 41
6.2
7.0
1.37
(0.215~1.60)
1.57
(0.245~2.25)
59
59
183
197
4.5
4.5
Outdoor
CS-E18GKR
(CU-E18GKR)
5.30
(0.90~6.00)
6.60
(0.90~8.00)
18,100
(3,070~20,500)
22,500
(3,070~27,300)
10
(49)
275 x 998 x 230
(750 x 875 x 345)
2.9
20
3.21
3.69
44 / 37 / 34
44 / 37 / 34
47 / 42
47 / 42
7.3
7.9
1.65
(0.215~2.05)
1.79
(0.245~2.65)
60
60
253
278
5.0
5.0
Outdoor
CS-E12GKR
(CU-E12GKR)
3.50
(0.80~4.00)
4.90
(0.80~6.70)
11,900
(2,730~13,600)
16,700
(2,730~22,800)
9
(35)
280 x 799 x 183
(540 x 780 x 289)
2.0
15
3.63
3.89
42 / 29 / 21
42 / 33 / 30
48 / —
50 / —
61
63
4.3
5.6
0.965
(0.185~1.20)
1.26
(0.175~1.89)
187
195
6.0
5.5
Outdoor
Cooling
Heating
EER: Cooling Efficiency
COP: Heating Efficiency
( ): Outdoor Unit
CS-E21GKR
(CU-E21GKR)
7.40
(0.90~8.10)
8.60
(0.90~9.90)
25,200
(3,070~27,600)
29,300
(3,070~33,800)
11
(63)
275 x 998 x 230
(795 x 900 x 320)
4.3
30
3.02
3.43
47 / 38 / 35
47 / 38 / 35
52 / 47
52 / 47
11.0
11.1
2.45
(0.35~2.70)
2.51
(0.36~3.20)
66
66
282
305
4.0
4.0
Outdoor
CS-E24GKR
(CU-E24GKR)
CS-E28GKR
(CU-E28GKR)
A i r C o n d i t i o n e r s
2 0 0 7 / 2 0 0 8
Energy
Materials
Factories
Our energy-conservation technologies help
to minimise energy consumption.
None of the products we ship contain any
specified chemical substances* regardless
of market.
* Lead, cadmium, hexavalent chromium, mercury, specified
bromine frame retardants (PBB, PBDE)
Our manufacturing sites around the world
have acquired ISO 14001 certification.
The Matsushita Group actively develops environmentally-conscious products.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Panasonic
- Model
- 2008
- Document type
- Manual
- Language(s)
- English
- Pages
- 16
- File size
- 5.7 MB
- Format
Summary
Cover page identifying the Panasonic air conditioner models 2007/2008, highlighting the e-ion Air Purifying System and INVERTER technology, and showing unit design components like the PATROL SENSOR.
Introduction to improved air quality, energy efficiency, and precise temperature control offered by the new Panasonic air conditioners.
Categorization of wall-mounted split air conditioning units based on inverter and non-inverter types, detailing capacities, features, and quiet mode performance.