Nutone WS3 - Manual

Nutone WS3

Nutone WS3 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – PREPARE HOOD LOCATION; VERTICAL DUCTING
  • Page 3 – PREPARE THE HOOD
  • Page 5 – CONNECT WIRING
  • Page 6 – OPERATION; CLEANING
  • Page 7 – SERVICE PARTS
  • Page 8 – WARRANTY
  • Page 9 – ADVERTENCIA; LEA Y CONSERVE ESTAS INSTRUCCIONES; PRECAUCION; Página 9
  • Page 10 – PREPARACIÓN DE LA CAMPANA
  • Page 11 – CAMPANA EXTRACTORA
  • Page 13 – CONEXIÓN ELÉCTRICA
  • Page 14 – FILTROS SIN CONDUCTOS; LIMPIEZA
  • Page 15 – PIEZAS DE SERVICIO
  • Page 16 – GARANTIA
Loading the manual

®

Page 1

ALLURE

®

WS3 SERIES

RANGE HOOD

!

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you

have questions, contact the manufacturer at the address or telephone
number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel and

lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means can-
not be locked, securely fasten a prominent warning device, such as a
tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified

person(s) in accordance with all applicable codes and standards, in-
cluding fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of gases

through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society of Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electrical

wiring and other hidden utilities.

6. To reduce the risk of fire or electric shock, do not use this range hood

with an additional speed control device.

7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1. Never leave surface units unattended at high settings. Boilovers cause

smoking and greasy spillovers that may ignite. Heat oils slowly on low
or medium settings.

2. Always turn hood ON when cooking at high heat or when cooking

flaming foods.

3. Clean ventilating fans frequently. Grease should not be allowed to

accumulate on fan or filter.

4. Use proper pan size. Always use cookware appropriate for the size of

the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF
A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal

tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If
the flames do not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent

steam explosion will result.

4. Use an extinguisher ONLY if:

A. You know you have a Class ABC extinguisher and you already

know how to operate it.

B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.

ALLURE

®

WS3 SERIES
RANGE HOOD

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with
the homeowner.
Homeowner: Operating and
Cleaning information on page 6.

CAUTION

1. For general ventilating use only. Do not use to exhaust hazardous or

explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced impel-

lers, keep drywall spray, construction dust, etc. off power unit.

3. For best capture of cooking impurities, your range hood should be

mounted so that the top of the hood is 24-30” above the cooking
surface.

4. Please read specification label on product for further information and

requirements.

TABLE OF CONTENTS

This manual is divided into sections as follows:

“PREPARE HOOD LOCATION”

Run ductwork from roof or wall cap, and electrical wiring from
service panel - to installation location

“PREPARE THE HOOD”

Get your hood ready for installation

“CONNECT WIRING”

Make electrical wiring connections to hood

“INSTALL HOOD”

Secure hood to cabinet and ductwork - install bulbs and filters

“OPERATION”

How to use the hood controls

“CLEANING”

Keep your hood in top working condition

“SERVICE PARTS”

Part numbers and exploded view of hood components

“WARRANTY”

One-year limited warranty and how to contact us

NOTE

If hood is to be installed Non-Ducted:
• Purchase a set of (2) non-ducted filters from your

local distributor or retailer and attach them to the
aluminum mesh filters.

Patent No.:
US D450, 829 S

!

FOR DOMESTIC COOKING ONLY

!

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - PREPARE HOOD LOCATION; VERTICAL DUCTING

® Page 2 ALLURE ® WS3 SERIES RANGE HOOD CABINETBOTTOM CABINET FRONT HORIZONTAL DUCT ACCESS HOLE 5¼" 5¼" 7½" 1/8 " ¾" 13 15/16 " (30" hood) 16 15/16 " (36" hood) 13 15/16 " (30" hood) HOOD MOUNTING SCREWS (4) ELECTRICAL ACCESS HOLE (in wall) 3¾" 16 15/1...

Page 3 - PREPARE THE HOOD

® Page 3 ALLURE ® WS3 SERIES RANGE HOOD PREPARE THE HOOD PREPARE THE HOOD 4 Remove Damper/DuctConnector from insidethe hood. Setconnectoraside - withmountingscrews andparts bag. 3 Remove Teflon ® -coated bottom cover from hood. Setcover andmountingscrews aside. 5 Removeeither top orback wiringknocko...

Page 5 - CONNECT WIRING

® Page 5 ALLURE ® WS3 SERIES RANGE HOOD CONNECT WIRING WARNING: To reduce the risk of electric shock,make sure power is switched off at the servicepanel. Lock or tag service panel to prevent powerfrom being switched on accidentally. HOUSE WIRING (120 VAC) CARDBOARD (Use to protect cooktop) 1 Connect...