Nutone LS100LF - Manual

Nutone LS100LF

Nutone LS100LF – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
Page: / 10

Table of Contents:

  • Page 3 – FIGURE 5; One Year Limited Warranty; GRILLE/LIGHT INSTALLATION; LAMP REPLACEMENT
  • Page 4 – AVERTISSEMENT: POUR RÉDUIRE LES RISQUES; A. Utiliser cet appareil seulement pour les fins prévuespar le; DIRECTIVES D' INSTALLATION; AVERTISSEMENT: POUR RÉDUIRE LES RISQUES D’INCENDIE, DE; électriques et les autres canalisations.; FIGURE 1; FIGURE 2
  • Page 5 – FIGURE 3; PREPARATION
  • Page 6 – FIGURE 4; Garantie limitée d’un an; INSTALLATION DE L’ÉCLAIRAGE/GRILLE; REMPLACEMENT DE L’AMPOULE
  • Page 7 – PREPARACION; Ventilador Ultra-QuieTTest; FIGURA 1; FIGURA 2
  • Page 8 – FIGURA 3
  • Page 9 – FIGURA 4; Garantía Limitada de un Año; INSTALACIÓN DE LA REJILLA Y LA BOMBILLA; Consulte la Figura 4.; PARA CAMBIAR LA BOMBILLA
  • Page 10 – PARTS LIST
Loading the manual

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK,

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Use this unit6 only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at service

panel and lock service panel to prevent power from being
switched on accidentally.
When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust hazardous

or explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified

person(s) in accordance with all applicable codes and standards, including fire-rated
construction.

B. Sufficient air is needed for proper combustion and exhausting of gases through the

flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating
equipment manufacturer's guideline and safety standards such as those published by
the National Fire Protection Association (NFPA),and the American Society for
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE),
and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring

and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for

the application and be connected to a GFCI (Ground Fault Circuit Interrupter)
protected branch circuit.

F.

NEVER

place a switch where it can be reached from a tub or shower.

Do not install in a ceiling insulated to a value greater than R40.

Suitable for use with solid state speed controls. Use NuTone Model VS-64.

Not for use in kitchens.

FOR BEST RESULTS

When installing the Ventilator in a

new construction site,

install housing during

the rough-in construction of the building. The blower unit and grille should be installed
after the finished ceiling is in place.

To install this ventilator in an

existing building

requires an accessible area (attic or

crawl space) above the planned location.

INSTALLATION IN A NEW CONSTRUCTION SITE

PREPARATION

1. Remove blower/power unit assembly from housing
2. Remove wiring knockouts from housing, as needed.

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

Ultra-QuieTTest Fans/Lights

MODELS: LS80LF, LS100LF

SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE
WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT.

FIGURE 1

ROOF CAP

4" DIAMETER DUCT

90° ELBOW

WALL CAP

CEILING INSTALLATION

FIGURE 2

GROUND

SCREW

120v AC SUPPLY

WHITE (NEUTRAL)

SWITCH BOX

FAN

RECEPTACLE

LAMP

RECEPTACLE

(3 PIN)

BLACK (HOT)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - FIGURE 5; One Year Limited Warranty; GRILLE/LIGHT INSTALLATION; LAMP REPLACEMENT

FIGURE 5 Product specifications subject to change without notice. 4820 Red Bank Road, Cincinnati, Ohio 45227 Printed in U.S.A., Rev. 05/2001, Part No. 88964 One Year Limited Warranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free fr...

Page 4 - AVERTISSEMENT: POUR RÉDUIRE LES RISQUES; A. Utiliser cet appareil seulement pour les fins prévuespar le; DIRECTIVES D' INSTALLATION; AVERTISSEMENT: POUR RÉDUIRE LES RISQUES D’INCENDIE, DE; électriques et les autres canalisations.; FIGURE 1; FIGURE 2

INSTRUCTIONS D'INSTALLATION LIRE ET CONSERVER CES INSTRUCTIONS Le ventilateur comprend un boîtier, des supports de montage, un couvercle de boîte de jonction, un ensemble moteur/ventilateur (moteur,roue, plaque de montage) et une grille. • Pour utilisation avec les commandes de vitesse électroniques...

Page 5 - FIGURE 3; PREPARATION

FIGURE 3 OUVERTURE DE DÉCHARGE BOÎTIER PATTE DEFIXATION VIS DE MONTAGE RESSORT DE MONTAGE BOSSAGE CRANTE MOTEUR LA GRILLE POUR OBTENIR LES MEILLEURS RÉSULTATS Pour poser le ventilateur dans les nouvelles constructions, installer le boîtier au stade de la construction brute de l'immeuble, Leventilate...