  • Page 3 – ÉLABORATION; ASSUREZ-VOUS QUE LE COURANT ÉLECTRIQUE SOIT; Lorsque vous fixez le câblage électrique sur les plots; Reportez-vous à la Figure 2 pour une installation simple de; . Tirez un câble double conducteur de 18-22 de jauge; NOTEZ: Une fois l’installation achevée, si le carillon ne; MONTER LE COUVERCLE DU CARILLON; Placez le carille au-dessus de la plaque d’assise. Assurez-vous; INSTRUCTIONS POUR L’ENTRETIEN; FIGURE 1; PIECES OU SERVICE DE RECHANGE
  • Page 4 – Garantie limitée d’un an
  • Page 5 – PLANIFICACIÓN; ASEGÚRESE DE QUE LA ELECTRICIDAD DE LA CASA; MONTAJE DE LA CUBIERTA; FIGURA 1; PARA PIEZAS DE REPUESTO O SERVICIO
  • Page 6 – Garantía Limitada de un Año
Loading the manual

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

Two-Note
Surface-Mounted
Door Chimes

MODELS: LA-155GN and LA-157MA

PLANNING

Your NuTone Door Chime is designed for two-door operation.

If the home is multiple-level or large ranch style, two or more
chimes should be used to provide adequate coverage.

Handle the door chime carefully, as you would any precision
instrument.

WIRING

BE SURE HOUSE POWER IS TURNED OFF WHEN WIRING

THE TRANSFORMER. WIRING CONNECTIONS MUST COMPLY
WITH LOCAL OR NATIONAL WIRING CODES.

For a single installation, use NuTone Model 515T or 101T Transformer.

For two or more chimes, use NuTone Model 105T or 301T Transformer.

NOTE:

When fastening chime wiring to wall studs and ceiling

joists, care must be taken to avoid possible “shorts” that might be
created by allowing staples or clips to cut through the protective
wiring insulation.

Refer to Figure 1.

Mount the transformer to a convenient junction

box (attic location is not recommended) or circuit breaker box.
Connect house power leads to transformer leads – black to black
and white to white.

Refer to Figure 2 for single chime installation or to Figure 3

for multiple chime installation

. Run 2 conductor 18-22 gauge

wire from transformer and the pushbutton(s) to chime location(s).
Bring the wires through the wiring hole in the chime baseplate(s)
and fasten the baseplate(s) to the wall though the mounting holes
with the screws provided. Connect the transformer and the
pushbutton wires to the chime terminal board(s).

NOTE: Upon completion of installation, if the chime does not

operate properly, check the pushbutton(s) for poor contact or
loose connections. Be certain wires are not touching the tone
bars.

MOUNTING COVER

Place the chime over the baseplate. Make sure hanger bracket

engages slot in top of baseplate.

MAINTENANCE INSTRUCTIONS

If chime plungers should ever become “sluggish” in their

movement, clean plungers with a nonflammable cleaning fluid and
wipe dry.

CAUTION: NEVER OIL CHIME PLUNGERS.

REPLACEMENT PARTS OR SERVICE

Contact your local Authorized NuTone Parts Outlet or Service

Center. If you are unable to locate the facility, write NuTone Inc.,
Madison and Red Bank Roads, Cincinnati, Ohio 45227-1599.
Attention: Department of National Field Service.

FIGURE 1

FIGURE 2

FIGURE 3

TERMINAL
BOARD
CHIME NO. 1

TERMINAL
BOARD
CHIME NO. 2

REAR DOOR
PUSHBUTTON

COMMON WIRES

FRONT DOOR
PUSHBUTTON

FRONT DOOR
PUSHBUTTON

SINGLE
2-NOTE CHIME

MULTIPLE
2-NOTE CHIMES

18-22 GA. INSULATED
2-CONDUCTOR WIRE

18-22 GA. INSULATED
2-CONDUCTOR WIRE

NUTONE 105T
OR 301T
TRANSFORMER

NUTONE 101T
OR 515T
TRANSFORMER

120vAC WIRING

120vAC WIRING

REAR DOOR
PUSHBUTTON

TERMINAL
BOARD

FRONT

TRANS

REAR

FRONT

TRANS

REAR

FRONT

TRANS

REAR

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - One Year Limited Warranty

Product specifications subject to change without notice.Printed in U.S.A., Rev. 4/01, Part No. 85722 One Year Limited Warranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of o...

Page 3 - ÉLABORATION; ASSUREZ-VOUS QUE LE COURANT ÉLECTRIQUE SOIT; Lorsque vous fixez le câblage électrique sur les plots; Reportez-vous à la Figure 2 pour une installation simple de; . Tirez un câble double conducteur de 18-22 de jauge; NOTEZ: Une fois l’installation achevée, si le carillon ne; MONTER LE COUVERCLE DU CARILLON; Placez le carille au-dessus de la plaque d’assise. Assurez-vous; INSTRUCTIONS POUR L’ENTRETIEN; FIGURE 1; PIECES OU SERVICE DE RECHANGE

INSTRUCTIONS D’INSTALLATION LISEZ ET CONSERVEZ CES INSTRUCTIONS! Carillon de Ported’entrée à 2 Notesmonté en applique MODÈLES: LA-155GN et LA-157MA ÉLABORATION • Votre carillon de porte d’entrée NuTone est conçu pour fonctionneravec deux portes d’entrée. • Si la maison comporte plusieurs étages ou e...

Page 4 - Garantie limitée d’un an

4820 Red Bank Road, Cincinnati, Ohio 45227Imprimé aux É.-U. Les caractéristiques peuvent être modifiées sans préavis Garantie limitée d’un an GARANTIE DU PROPRIÉTAIRE: NuTone garantie à l'acheteur original de ses produits que ces derniers seront exempts de tout défaut de matériaux et de fabrication ...

Other Nutone Models