Architectural & Engineering Specifications

February 2002

Fan Forced Wall Heater

MODELS: 9810, 9815, 9819 Series

DESCRIPTION

Attractive white on brown wood-grain grille brings cozy warmth to any room. Exceptionally
durable grilles are heat resistant.

Quiet fan and downflow action circulates heated air quickly.

Three models offer wattage choice: 1000, 1500, 1920w. Heaters easily wired at installation
for 120 or 240v. Over temperature protected by thermal fuse.

Built-in adjustable thermostat. Quiet thermally-protected motor and transverse flow blower.

Long-life bearings with extra large oil reservoir.

Hang tab aids installation.

DESIGN FEATURES

Electrical Rating:

120/240 volts

9810 Series:

1050 total watts

9815 Series:

1550 total watts

9819 Series:

1970 total watts

Housing:

Dimensions:

12

1

2

” x 10

1

2

” 3

3

8

”.

Material:

Cold rolled steel,

Finish:

Enamel

Grille:

Dimensions:

14

3

4

” x 11

9

16

”.

Material:

Polymeric.

Finish:

Brown wood-grain or white.

Impeller :

Type:

Tangential.

Dimensions:

7

1

8

x 2

3

8

.

Element:

Type:

Coiled resistance wire

Wattage:
9810 Series:

1000.

9815 Series:

1500

9819 Series:

1920.

Material:

Nickel-Chromium

Motor:

Thermally protected, shaded pole,
sleeve bearings.

Switch:

Type:

On/Off switch provided as

part of thermostat.

12

1

/

2

"

10

1

/

2

"

14

3

/

4

"

11

9

/

16

"

3

3

/

8

"

INSTALLATION

Complete instructions included with each unit.

ARCHITECTS SPECIFICATIONS

Fan Forced Wall Heater(s) shall be models 9810BWN, 9815BWN,

or 9819BWN with brown grille or Models 9810WH, 9815WH or
9819WH with white grille as manufactured by NuTone according to
listed specifications.

NUTONE, INC.

/ 4820 RED BANK ROAD, CINCINNATI, OHIO 45227

Product specifications subject to change without notice.

REFERENCE

QTY.

REMARKS

Project

Location

Architect

Engineer

Contractor

Submitted by