Nutone 8833 - Manual

Nutone 8833

Nutone 8833 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – FIGURE 4; BLOWER; Installation Hints; One Year Limited Warranty
  • Page 3 – Ventilateur de salle de bain; FIGURE 1; IMPORTANT SAFETY INSTRUCTIONS; INSTALLATION INSTRUCTIONS; POUR DE MEILLEURS RESULTATS; ATTENTION: Ne pas installer l’appareil au-dessus du bain ni de la; INSTALLATION DANS UNE MAISON NEUVE; de 3 po entre le boîtier et la sortie sur le toit ou la sortie murale.; Voir les Figures 2 et 3.; PLAFOND; FIGURE 2; MUR; FIGURE 3; DIRECTIVES D’INSTALLATION; ATTENTION: S’assurer que les fils sont conformes aux
  • Page 4 – VENTILATEUR; Les caractéristiques peuvent être modifiées sans préavis.; Trucs d’installation; Garantie limitée d’un an
Loading the manual

Bathroom Ventilator

MODELS: 8832WH, 8832SA & 8833

FIGURE 1

ADJUSTABLE
ELBOW

• Do not mount over tub or in shower stall enclosure.
• Not for use in kitchens.

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at service panel and lock

service panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust hazardous or

explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by

qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.

B. Sufficient air is needed for proper combustion and exhausting of gases

through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire Protection
Association (NFPA),and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must

be marked as appropriate for the application.

F. NEVER place a switch where it can be reached from

a tub or shower.

G. Do not use this fan with any solid-state speed control device.

FOR BEST RESULTS

When installing the ventilator in a new construction site, install

the housing during the rough-in construction of the house. Blower
and grille should be installed after finished ceiling is in place.

To install the ventilator in an existing house requires accessible

area above the proposed installation location (attic or crawl space).
The housing must be installed to a finished ceiling from above.

LOCATION

The ventilator is intended for installation in bathroom or laundry.

CAUTION: Do not install the unit over a tub or in a shower

stall enclosure.

ROOF
CAP

WALL
CAP

IN CEILING

TRANSITION
FURNISHED
WITH WALL CAP

3"
ROUND
DUCT

FIGURE 2

ADJUSTABLE
ELBOW

ROOF
CAP

WALL
CAP

IN WALL

TRANSITION
FURNISHED
WITH WALL CAP

3"
ROUND
DUCT

FIGURE 3

STANDARD
WALL
SWITCH

GREEN

GROUND

SCREW

SWITCH
BOX

JUNCTION

BOX

EARTH
GROUND

120vAC, 60Hz

HOUSE POWER

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

INSTALLATION IN A NEW
CONSTRUCTION SITE

1. Remove the blower unit from the housing by unplugging it then loosening

the three mounting screws and rotating the unit to free it from the screws.

2. Loosely attach housing to ceiling joists through keyhole slots

in mounting brackets. Keyhole slots in brackets are provided
to allow for adjustment to various ceiling thicknesses. Adjust
housing so bottom is flush to proposed finished plaster line,
then securely fasten housing to joists.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FIGURE 4; BLOWER; Installation Hints; One Year Limited Warranty

FIGURE 4 BLOWER MOUNTINGSTUD MOUNTINGSCREWS (3) Product specifications subject to change without notice. 4820 Red Bank Road, Cincinnati, Ohio 45227 Printed in U.S.A., Rev. 01/2004, Part No. 84762 INSTALLATION IN A NEWCONSTRUCTION SITE (continued) 3. Snap duct adapter over flanges on housing. Run 3&#...

Page 3 - Ventilateur de salle de bain; FIGURE 1; IMPORTANT SAFETY INSTRUCTIONS; INSTALLATION INSTRUCTIONS; POUR DE MEILLEURS RESULTATS; ATTENTION: Ne pas installer l’appareil au-dessus du bain ni de la; INSTALLATION DANS UNE MAISON NEUVE; de 3 po entre le boîtier et la sortie sur le toit ou la sortie murale.; Voir les Figures 2 et 3.; PLAFOND; FIGURE 2; MUR; FIGURE 3; DIRECTIVES D’INSTALLATION; ATTENTION: S’assurer que les fils sont conformes aux

Ventilateur de salle de bain MODELES: 8832WH, 8832SA et 8833 FIGURE 1 COUDE REGLABLE • Ne pas installer au-dessus du bain ni de la douche.• Ne pas installer dans la cuisine. IMPORTANT SAFETY INSTRUCTIONS WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS, OBSERVE THE FOLLOWING...

Page 4 - VENTILATEUR; Les caractéristiques peuvent être modifiées sans préavis.; Trucs d’installation; Garantie limitée d’un an

FIGURE 4 VENTILATEUR BRIDE DEFIXATION VIS DEFIXATION Les caractéristiques peuvent être modifiées sans préavis. 4820 Red Bank Road, Cincinnati, Ohio 45227 Imprimé aux E.-U. INSTALLATION DANS UNE MAISON NEUVE (suite) 5. Voir la Figure 4. Insérer le ventilateur dans le boîtier, le montant de la bride d...

Other Nutone Models