Nutone 672R - Manual

Nutone 672R

Nutone 672R – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 4 – Ventilateur d’évacuation; POUR DE MEILLEURS RESULTATS; DIRECTIVES D' INSTALLATION; MONTAGE DU BOITER
  • Page 5 – INSTALLATION DU MOTEUR
  • Page 6 – PARTS LIST
Loading the manual

READ & SAVE THESE INSTRUCTIONS!

INSTALLATION INSTRUCTIONS

Exhaust Fan

MODELS: 671R & 672R

The Exhaust Fan consists of the housing, power unit/blower

assembly (motor, wheel, mounting plate), grille and duct collar.

FAN MUST NOT BE INSTALLED IN A CEILING INSULATED
TO A VALUE GREATER THAN R-40.

SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE
WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT

.

FOR BEST RESULTS

When installing the Exhaust Fan in a new construction site,

install the housing during the rough-in construction. The blower
unit and grille should be installed after the finished ceiling is in
place.

To install the Exhaust Fan in an existing finished building, an

accessible area is required above the planned location (attic or
crawl space).

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC

SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:

A. Use this unit only in the manner intended by the

manufacturer. If you have questions, contact the
manufacturer.

B. Before servicing or cleaning unit, switch power off at service

panel and lock service panel to prevent power from being
switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust

hazardous or explosive materials and vapors.

WARNING:

To reduce the risk of fire or electric shock, do not

use this fan with any solid-state speed control.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:

A. Installation work and electrical wiring must be done by

qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.

B. Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.

FIGURE 1

DUCT COLLAR

HOUSING

SLOTS

POWER UNIT/BLOWER
ASSEMBLY

MOUNTING TAB

TABS

GRILLE

C. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) protected branch
circuit.

F. NEVER place a switch where it can be reached from a tub or

shower.

COLLIER DE GAINE

BOITER

FENTES

ENSEMBLE MOTEUR/
VENTILATEUR

LA GRILLE

PATTES

PATTES DE MONTAGE

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 4 - Ventilateur d’évacuation; POUR DE MEILLEURS RESULTATS; DIRECTIVES D' INSTALLATION; MONTAGE DU BOITER

LEA Y GUARDE ESTAS INSTRUCCIONES ¡INSTRUCCIONES PARA LA INSTALACION! Ventilateur d’évacuation MODELES: 671R et 672R Le ventilateur comprend: le boîter. le bloc-moteur (moteur, aubes, plaque de montage), la grille et le collier de gaine. LE VENTILATEUR NE DOIT PAS ETRE INSTALLE DANSUN PLAFOND A ISOLA...

Page 5 - INSTALLATION DU MOTEUR

Utilisation de Barres de Suspension(Les barres de suspension sont venduesséparément; commandez le modèle HB4) Voir Figure 3. 1. Insérez les barres de suspension dans les fentes situées sur l’habitacle. 2. Positionnez l’habitacle de ventilation entre les traverses du plafond afin que le dessous de l’...

Page 6 - PARTS LIST

671R, 672R Rev. DECEMBER 1999 CURRENT ORIGINAL MODEL USED ON REPLACEMENT REF. PART NO. PART DESCRIPTION PART NO. 1 86863 MOTOR MOUNTING PLATE 671R, 672R 86863-000 2 32787 MOTOR ISOLATION MOUNT 671R, 672R 32787-000 3 32788 GROUND CLIP 671R, 672R 32788-000 86933 MOTOR 672R 86933-000 87594 MOTOR 671R 8...