LIABILITY DISCLAIMER NEC Corporation reserves the right to change the specifications, functions, or features, at any time, without notice. NEC Corporation has prepared this document for use by its employees and customers. The information contained herein is the property of NEC Corporation and shall ...
Page 5 - General Description; TABLE OF CONTENTS; Page; Figures of D
ND-91649(E) ISSUE 3 ND-91649(E) TABLE OF CONTENTS Page i NEAX 2000 IPS General Description TABLE OF CONTENTS Page CHAPTER 1 INTRODUCTION ............................................................................................................. 1 System Overview ......................................
Page 6 - Figure Title
ND-91649(E) ISSUE 3 LIST OF ILLUSTRATIONS ND-91649(E) Page ii LIST OF ILLUSTRATIONS Figure Title Page Figure 1-1 NEAX 2000 IPS ...................................................................................................................................1 Figure 1-2 NEAX 2000 IPS System Overview...
Page 7 - Table Title; Table 3-2 Combination Pattern of Optional Accessories to the D
ND-91649(E) ISSUE 3 ND-91649(E) LIST OF TABLES Page iii LIST OF TABLES Table Title Page Table 1-1 Technical Terms of NEAX 2000 IPS System ....................................................................................8 Table 2-1 Modules of NEAX 2000 IPS System .....................................
Page 9 - INTRODUCTION; CHAPTER 1 INTRODUCTION; IPs and for CCIS connections with another; IP/CCIS over IP and legacy
ND-91649(E) CHAPTER 1 Page 1 INTRODUCTION CHAPTER 1 INTRODUCTION This document provides an overview of the NEAX 2000 IPS (Internet Protocol Server) stored program control digital electronic PBX. An introduction to the technical characteristics is included, along with a description of available syste...
Page 10 - IP telephones with voice compression, on a CCIS basis (CCIS; Softphone SP30) to connect to LAN network; features without the telephone set.; IP telephones and; Authorization Code with AP01; Peer to Peer; IP Switched
CHAPTER 1 ND-91649(E) Page 2 INTRODUCTION D term IP telephones are designed to provide a converged infrastructure at the desktop, with a 100 Base T Ethernet connection to the LAN and built-in hub for a PC connection to the telephone itself. The system can provide peer-to-peer connections between D t...
Page 11 - connected to the station through local TDSW.
ND-91649(E) CHAPTER 1 Page 3 INTRODUCTION Remote PIM over IP NEAX 2000 IPS can install a PIM at remote site through IP network. At the main site, the NEAX 2000 IPS is installed and the Remote PIM is installed at remote site. The main site controls call processing and service feature access for stati...
Page 13 - Hardware Architecture; Reduced Hardware with IP-based Architecture; Standard TDM Hardware; Application Processors; IP and inter-work with MATWorX and OAI server.
ND-91649(E) CHAPTER 1 Page 5 INTRODUCTION Hardware Architecture Reduced Hardware with IP-based Architecture The D term IPs, D term Softphone and IP-BS connected to the LAN do not require any special interface cards* because they can be interfaced directly with the LAN and connected with peer-to-peer...
Page 14 - Floor Standing Installation
CHAPTER 1 ND-91649(E) Page 6 INTRODUCTION Extended Application Processor (AP) Port Capacity The NEAX 2000 IPS provides a maximum of 256 AP ports and it is independent of the 512 ports for the Line/Trunk (LT), therefore, more AP cards such as T1/E1 digital link cards can be used in the system. Univer...
Page 15 - Software Architecture; Office Data Backup Enhancement
ND-91649(E) CHAPTER 1 Page 7 INTRODUCTION Software Architecture Built-in DRS (Device Registration Server) on MP The NEAX 2000 IPS incorporates DRS (Device Registration Server) on the MP. DRS provides Log-in/Log-out management of D term IP including Registration and Authentication. Also, the built-in...
Page 16 - Technical Terms; Table 1-1 Technical Terms of NEAX 2000 IPS System
CHAPTER 1 ND-91649(E) Page 8 INTRODUCTION Technical Terms Table 1-1 Technical Terms of NEAX 2000 IPS System SYMBOL DESCRIPTION SYMBOL DESCRIPTION AMP Amplifier Trunk Card LC Line Circuit Card (for Single Line Telephone) AP00 SMDR/Hotel Application Card LDT LD Trunk Card BGM External Music Source for...
Page 17 - Trunking Diagram; Figure 1-6 Trunking Diagram of NEAX 2000 IPS
ND-91649(E) CHAPTER 1 Page 9 INTRODUCTION Trunking Diagram This figure shows a typical trunking diagram of the NEAX 2000 IPS system. Figure 1-6 Trunking Diagram of NEAX 2000 IPS
Page 18 - CHAPTER 2; SYSTEM CONFIGURATION; CHAPTER 2 SYSTEM CONFIGURATION; Figure 2-1 Module Configuration of NEAX 2000 IPS
CHAPTER 2 ND-91649(E) Page 10 SYSTEM CONFIGURATION CHAPTER 2 SYSTEM CONFIGURATION Module Configuration The NEAX 2000 IPS consists of Port Interface Modules (PIM) depending on the system configuration, and there are two types of PIMs; “Physical” PIM and “Virtual” PIM. The Physical PIM is a “hardware”...
Page 19 - CHAPTER; Installation Methods; Figure 2-2 Face Layout of NEAX 2000 IPS
ND-91649(E) CHAPTER 2 Page 11 SYSTEM CONFIGURATION Installation Methods The NEAX 2000 IPS provides three installation methods as follows: Floor Standing Installation Wall Mounting Installation 19-inch Rack Mounting Installation Floor Standing Installation In Floor Standing Installation, the NEAX 200...
Page 23 - Common Control Cards; System Conditions; For the communication between D; IPs, the voice data is transmitted and received directly, without; IP to D; Conditions for H.323 Connection
ND-91649(E) CHAPTER 2 Page 15 SYSTEM CONFIGURATION Circuit Cards The circuit cards used for NEAX 2000 IPS are divided into the following three types. According to these card types, the mounting location of card and port allocation of the Time Division Switch are varied. Common Control Cards - Main P...
Page 24 - DRS = Device Registration Server; for the D; The DRS can be used as the Proxy server.
CHAPTER 2 ND-91649(E) Page 16 SYSTEM CONFIGURATION Conditions for Maintenance MATWorX can be used as the maintenance program for NEAX 2000 IPS. Direct connection (RS-232C), Modem connection and LAN (TCP/IP) connection are available to connect to the MAT (Maintenance Administration Terminal). Conditi...
Page 25 - TERMINALS; CHAPTER 3 TERMINALS
ND-91649(E) CHAPTER 3 Page 17 TERMINALS CHAPTER 3 TERMINALS A variety of terminal equipment may be connected to the NEAX 2000 IPS. The following equipment may be installed with the system. Attendant Console Desk Console D term Series i D term 2 (White/Black Color) : 2-button terminal D term 8 (White...
Page 26 - CHAPTER 3; Desk Console; SN716 DESKCON Features
CHAPTER 3 ND-91649(E) Page 18 TERMINALS Desk Console The SN716 Desk Console has an ergonomic design and provides full access to all PBX Console features. It connects to the NEAX 2000 IPS using the same circuit cards as the D term 75 Series terminals. The SN716 Desk Console operates on a switched-loo...
Page 27 - IP Digital Multifunction Terminals
ND-91649(E) CHAPTER 3 Page 19 TERMINALS D term Series i/D term IP Digital Multifunction Terminals The D term Series digital multifunction/multiline terminal is available in two colors to meet the needs of various users based on the features and types of communications each end user requires. D term ...
Page 28 - This D; 6LD (DESI Less 16 LD button D
CHAPTER 3 ND-91649(E) Page 20 TERMINALS D term Series i/D term IP Lineup D term 2 (2-button D term ) This D term Series Digital Multi-line Terminal is equipped with 8 dedicated Function keys (such as Hold, TRANSFER, ANSWER, SPEAKER, REDIAL, CONF, RECALL and FEATURE), 2 programmable Line/Feature keys...
Page 29 - IP Accessories; not
ND-91649(E) CHAPTER 3 Page 21 TERMINALS D term Series i/D term IP Accessories Direct Station Selection (DSS) Console This Console is equipped with 60 programmable line keys (each with a two-color LED). These keys can be programmed as Direct Station keys, Function keys, or Line keys. The DCU-60 Conso...
Page 30 - IP
CHAPTER 3 ND-91649(E) Page 22 TERMINALS Figures of D term Series i/D term IP * D term 2 (Black) is also supported. Figure 3-2 D term 2 (White) * D term 8 (Black) is also supported. Figure 3-3 D term 8 (White) * D term 8 D(Black) is also supported. Figure 3-4 D term 8D (White)
Page 35 - X X X
ND-91649(E) CHAPTER 3 Page 27 TERMINALS Table 3-2 Combination Pattern of Optional Accessories to the D term Series i/ D term IP Combination Pattern APR ADA CTA IPW WMU 1 X X 2 X 3 X X 4 X X 5 X X 6 X X 7 X X X 8 X X X 9 X X 10 X X X X : Available
Page 36 - Wireless System; Versatile Communication Tool for a variety of industries
CHAPTER 3 ND-91649(E) Page 28 TERMINALS Wireless System A mobile work force no longer has to be dependent on special technology. With personal telephone and Wireless Communication System, employees can travel throughout a multistored building or across a large industrial complex and continue t...
Page 38 - Specification of Personal Station; Item Specifications; Feature
CHAPTER 3 ND-91649(E) Page 30 TERMINALS Personal Handyphone System (PHS) Personal Station (PS) The PS (Personal Station) incorporates the 32 Kbps ADPCM encoding technique and privacy function so that you can talk about even important matters in a noise-free, very clear voice. Since the PS is lig...
Page 39 - Specification of Cell Station
ND-91649(E) CHAPTER 3 Page 31 TERMINALS Cell Station (CS) Because of its small size, light weight and slenderness, the CS can be installed anywhere...the wall surface, the ceiling or behind the ceiling. In addition, its expansion or relocation can be smoothly performed. Followings are the specif...
Page 40 - Specification of IP Base Station
CHAPTER 3 ND-91649(E) Page 32 TERMINALS IP Base Station (IP-BS) PHS Base Station is installed on the IP network and LAN, and Wireless Communication System can be built. Management such as wiring can be reduced by IP-ization. Specification of IP Base Station Table 3-5 IP Base Station (IP-BS) Sp...
Page 45 - Softphone provides the IP-enabled D; features without the telephone set, and it works on the; SP30 provides call logs for all; Manual entry; SP30 Softphone
ND-91649(E) CHAPTER 3 Page 37 TERMINALS D term Softphone (SP30) This D term Softphone provides the IP-enabled D term features without the telephone set, and it works on the Windows PC connected to LAN network. You click the button on the picture, the button, lamp and LCD works like an actual telepho...
Page 46 - Subpanels and Functions
CHAPTER 3 ND-91649(E) Page 38 TERMINALS Subpanels and Functions Function Key Panel Displays lines and functions set for PBX and enables changing of button name and pop-up. Short Message Log Panel Displays transmission, reception and error logs of simple messages and lets user select a log to telepho...
Page 47 - OVERVIEW OF INSTALLATION, PROGRAMMING, AND MAINTENANCE; CHAPTER 4 OVERVIEW OF INSTALLATION, PROGRAMMING, AND; Items to be Provided at Site; AC; Grounding Requirements; Communication grounding : Less than 10 ohm; CAUTION
ND-91649(E) CHAPTER 4 Page 39 OVERVIEW OF INSTALLATION, PROGRAMMING, AND MAINTENANCE CHAPTER 4 OVERVIEW OF INSTALLATION, PROGRAMMING, AND MAINTENANCE Installation Items to be Provided at Site The following items are required for correct operation. a.) Adequate space accommodation b.) Adequate ventil...
Page 48 - CHAPTER 4; Wrist Strap is connected to Frame Ground.; Various installation Methods; Programming; System Initialization
CHAPTER 4 ND-91649(E) Page 40 OVERVIEW OF INSTALLATION, PROGRAMMING, AND MAINTENANCE Installation of Main Equipment The installation of the NEAX 2000 IPS is comprised of up to 8 Port Interface Modules (PIMs). A PIM provides 13 card slot for Common Control, Line/Trunk (LT), and Application Porcessors...
Page 49 - CAT; MAT; Maintenance; Trouble Reporting and Diagnosis; Remote Maintenance
ND-91649(E) CHAPTER 4 Page 41 OVERVIEW OF INSTALLATION, PROGRAMMING, AND MAINTENANCE System Data Entry There are two methods for data entry, using a Customer Administration Terminal (CAT) or a Maintenance Administration Terminal (MAT). CAT Any D term can be assigned as a CAT through programming. The...
Page 50 - CHAPTER 5; SPECIFICATIONS; CHAPTER 5 SPECIFICATIONS; System Capacity Note 1, 2; Note 5
CHAPTER 5 ND-91649(E) Page 42 SPECIFICATIONS CHAPTER 5 SPECIFICATIONS System Capacity The following table shows the system capacity. Table 5-1 System Capacity (Single MP System) System Capacity Note 1, 2 Item 1PIM 2PIM 3PIM 4PIM 5PIM 6PIM 7PIM 8PIM 64 128 192 256 320 384 448 512 (No. of Ports) LT Ca...
Page 51 - System Capacity; “PIM” in this table means “Physical PIM.”; Maximum Voice Channels per IP PAD (32IPLA
ND-91649(E) CHAPTER 5 Page 43 SPECIFICATIONS Table 5-1 System Capacity (Single MP System) (Cont’d) System Capacity Item 1PIM 2PIM 3PIM 4PIM 5PIM 6PIM 7PIM 8PIM Attendant Terminal (D term ATT Position) Max. 8 sets per system SMDR Interface Max. 1 interface port per system PMS Interface Max. 1 interfa...
Page 52 - PSs; Payload Size; It is possible to connect 4 applications at the same time.
CHAPTER 5 ND-91649(E) Page 44 SPECIFICATIONS Table 5-1 System Capacity (Single MP System) (Cont’d) Note 4: Message Waiting Lamp is not available when the 4LLC is mounted in slot 08 to 10. Note 5: From FP 3300, maximum 256 PS can be accommodated to the system in addition to the maximum 512 LT ports. ...
Page 53 - IP Specifications; Table 5-2 IP Specifications
ND-91649(E) CHAPTER 5 Page 45 SPECIFICATIONS IP Specifications Table 5-2 IP Specifications ITEM SPECIFICATIONS REMARKS Voice Encoding G.729a G.723.1 (5.3 k/6.3 k) G.711 8 kbps CS-ACELP MP-MLQ/ACELP 64 Kbps PCM IP PAD 8/32 channels per card Automatically seized per call FAX Relay Method (T.30) G3 FAX...
Page 54 - IPs
CHAPTER 5 ND-91649(E) Page 46 SPECIFICATIONS Table 5-2 IP Specifications (Cont’d) ITEM SPECIFICATIONS REMARKS 0 dB to +16 dB (+2 dB increments) 0 dB to –16 dB (–2 dB increments) When using PN-8IPLA (IP PAD): 0 dB to +14dB (+2 dB increments) 0 dB to –14 dB (–2 dB increments) Setting is available per ...
Page 55 - Line Conditions; Table 5-3 Line Conditions; Note 3; Note 4; Cable length is based on the following conditions.
ND-91649(E) CHAPTER 5 Page 47 SPECIFICATIONS Line Conditions Table 5-3 Line Conditions Loop Resistance Note 1 Standard 600 ohms Analog Telephone Set Option 2,500 ohms (DP: 10pps), 1,700 ohms (DP: 20pps),1,200 ohms (DTMF) Exchange Line 1,700 ohms Loop Start Trunk Tie or DID Line 2,500 ohms Cable Leng...
Page 56 - Cell Station/Zone Transceiver Line Conditions; Table 5-4 Cell Station/Zone Transceiver Line Conditions; DESRIPTION; Cell Station; BS21A with AC Adapter; BS31 with AC Adapter; Note; ZTII-U with AC Adapter
CHAPTER 5 ND-91649(E) Page 48 SPECIFICATIONS Cell Station/Zone Transceiver Line Conditions Table 5-4 Cell Station/Zone Transceiver Line Conditions DESRIPTION SPECIFICATIONS Cell Station BS21A (for S-Interface) Max. 900 meters @-43V BS21A with AC Adapter Max. 960 meters @-43V BS31 (for U-Interface) M...
Page 57 - Traffic Capacity; The traffic load of each FP shall be 2500 BHCA or less.
ND-91649(E) CHAPTER 5 Page 49 SPECIFICATIONS Traffic Capacity Table 5-5 Traffic Capacity Number of PIMs 1PIM 2PIM 3PIM 4PIM 5PIM 6PIM 7PIM 8PIM Traffic Capacity Max. 2500 BHCA Max. 5000 BHCA Note Max. 7500 BHCA Note Max. 8000 BHCA Note Note: The traffic load of each FP shall be 2500 BHCA or less. DR...