MRCOOL MDHP1824NK35H05 - User Manual

MRCOOL MDHP1824NK35H05

MRCOOL MDHP1824NK35H05 Air Conditioner – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 2 – Contents; Page 1; Maintenance; Quick Connect
  • Page 3 – Page 2; WARNING; DO NOT; let substances or gases other than the refrigerant; modified, fire or even an explosion could occur.; Read Before Installation; Incorrect installation may cause serious damage or injury.; WARNING; or; CAUTION; WARNING; This symbol indicates that you should; never; perform the indicated action.; Safety Precautions
  • Page 4 – Page 3; Note about Flourinated Gasses:; otherwise electric shock may occur.
  • Page 5 – Page 4
  • Page 6 – Page 5; Appliance Overview
  • Page 7 – Page 6; Liquid Side Stub Kit
  • Page 8 – Page 7; COOLING; Operating Range; Outdoor Temperature; Unit Dimensions; Outdoor Unit Dimensions
  • Page 9 – Page 8; Do not install the unit in a location with direct sunlight.; Unit Installation; Installation Location; The Conventional Weld Line Set Installation; The UniversalTM Series has 2 installation methods; RCO
  • Page 10 – Page 9; Prohibited; For installation of a single condenser refer to fig 2.1 below:
  • Page 13 – WALL
  • Page 14 – secure the unit. Make sure the unit stands erect and level.; Outdoor Unit Installation
  • Page 15 – INSTALLATION METHOD; dents in the piping will affect the unit’s performance.; Conventional Line Set Installation; For installation with a; No-Vac® Quick Connect® Line Set; , refer to the next section starting on page 23
  • Page 16 – OIL RETURN BENDS; Add an oil return bend as described below:
  • Page 17 – Pipe Cutting; Pipe; DO NOT DEFORM PIPE WHILE CUTTING
  • Page 18 – Flare nut; PIPING EXTENSION BEYOND FLARE FORM; Step 3: Flare pipe ends; Pipe Flaring
  • Page 19 – Replacement Condenser Only; WELD Type Complete Unit Replacement
  • Page 20 – Pipe Bending; Extend the pipe by unwinding it; Radius; MINIMUM BEND RADIUS
  • Page 21 – DO NOT USE EXCESSIVE TORQUE; Knockout Holes; Post Installation Checks; Pipe Connection
  • Page 22 – Vacuum Lines; Connect the hose used for evacuation hose to the vacuum pump.; generally 30 minutes.; Return the caps to the liquid valve, gas valve and service port.
  • Page 24 – INSTRUCTIONS FOR USE WITH; NO-VACTM QUICK CONNECT® LINE SET; SOLD SEPARATELY; Please read and follow the instructions and diagram below; Complete unit replacement; Air Handler
  • Page 25 – lower; Installation of Drain Pipe
  • Page 26 – Condenser Field Conversion; and air handler split system to operate at 2 ton capacity.; Converting Unit From 3 Ton to 2 Ton; settings to convert the Universal Air Handler from 3 ton to 2 ton.
  • Page 27 – edge on the ceiling, or touch any metal burrs or sharp metal edge.; Electrical Connection; Electrical Regulations
  • Page 28 – Outdoor Unit Model; Electrical Parameters; Refer to
  • Page 29 – Connecting the Power Cord & Communication Wire; the wires with wire clamps (as; shown in; Cord Clamp; Before work begins, please check to ensure the unit is powered OFF.
  • Page 30 – clamps and the latter ones with small clamps.; POWER
  • Page 31 – wire and the power cord to the terminal board.
  • Page 32 – Refrigerant Piping Connection; List of Checks to Perform; Before Test Run; Electrical Safety Checks; – Confirm that the electrical system is safe and operating properly; Gas Leak Checks
  • Page 33 – Test Run Instructions; Preparation before connecting the power:; Control circuit is correct and all the wires are firmly connected.; Operation after connecting the power:; If all the above works are finished, power on the unit.; DOUBLE-CHECK PIPE CONNECTIONS; points do not have leaks.; Test Run
  • Page 34 – Troubleshooting; Problem
  • Page 35 – NOTICE; MRCOOL or your installing dealer.
  • Page 36 – Error Code; electric shock or a fire hazard.; Number Error Code
  • Page 37 – Unit Maintenance; Warning
  • Page 38 – Outdoor Heat Exchanger; avoid electric shock.; Condensate Drain
  • Page 39 – Notice on Maintenance; Service Information
  • Page 40 – Initial safety checks should include:; Electrical Device Checks; ignition of refrigerant in the atmosphere from a leak.; Intrinsically Safe Component Repair; ELECTRICAL SAFETY; ) Ensure the apparatus is securely mounted.
  • Page 41 – Cabling; ) You are familiar with the equipment and its operation.; Decommissioning procedure:; ) Take extreme care to avoid refrigerant overfill.
  • Page 42 – good practice that all refrigerants are removed safely.; Labelling; label must be dated and signed.
  • Page 43 – Special notice; ance, the law requires special collection and treatment.; dispose of this product as household waste; EU Disposal Guidelines
  • Page 44 – UniversalTM Series; Consult with the sales agency or manufacturer for details.; INSTALLATION LOCATION:
Loading the manual

Please read this manual carefully before installation and keep it for future reference.

Copyright © 2020 MRCOOL, LLC | v5.06.2020

Thank you for choosing MRCOOL Please read this manual carefully before installation and keep it for future reference.

Owner’s Manual

Universal

®

Series

DC Inverter / Condenser

MDUO18024036

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Contents; Page 1; Maintenance; Quick Connect

Contents Page 1 mrcool.com MC MC EU Disposal Guidelines ...... 42 5 Post Installation Checks ........... 31 3 Maintenance ............................... 33 1. Troubleshooting ....................................... 342. Error Codes ............................................... 353. Unit Maintenan...

Page 3 - Page 2; WARNING; DO NOT; let substances or gases other than the refrigerant; modified, fire or even an explosion could occur.; Read Before Installation; Incorrect installation may cause serious damage or injury.; WARNING; or; CAUTION; WARNING; This symbol indicates that you should; never; perform the indicated action.; Safety Precautions

Page 2 Safety Precautions mrcool.com WARNING Please read the manual in its entirety before installing, operating or repairing.DO NOT share the electrical circuit with other appliances. Improper or insufficient power supply can cause fire or electrical shock. When connecting refrigerant piping, DO NOT l...

Page 4 - Page 3; Note about Flourinated Gasses:; otherwise electric shock may occur.

Page 3 Safety Precautions mrcool.com Note about Flourinated Gasses: 1.2.3.4.5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 6. 5. Install the unit in a firm location that can support the unit’s weight. If the installation location cannot support the weight, or the installation is performed improperly, the unit ma...