Table of Contents:

  • Page 2 – Unit Specifications and Features; Owner’s Manual; Table of Contents; Safety Precautions
  • Page 3 – Installation Manual
  • Page 4 – Read Safety Precautions Before Operation and Installation; WARNING; or MrCool®; Do not; CLEANING AND MAINTENANCE WARNINGS; Do not; WARNING; This symbol indicates the possibility; CAUTION; This symbol indicates the possibility of
  • Page 5 – ELECTRICAL WARNINGS; or similarly qualified persons in order to avoid a hazard.; can cause fire or electrical shock.; TAKE NOTE OF FUSE SPECIFICATIONS
  • Page 6 – WARNINGS FOR PRODUCT INSTALLATION; do not; the
  • Page 7 – Page 6; Disposal Guidelines; dispose of this product as; Special notice; C o rrect D isp o sal o f T h is Pro d u ct; WARNING for Using R32/R290 Refrigerant; where the room size corresponds to the room area as specifie; UL; IEC; Standard Requirements)
  • Page 8 – Page 7; Indoor unit display; Display Code; Different models have
  • Page 9 – Page 8
  • Page 10 – Page 9; Operating temperature; To further optimize the performance of your unit, do the following:; Keep doors and windows closed.; Inverter Split Type; When outside
  • Page 11 – Other Features; to; Wireless Control; manual; Sleep Operation; HEAT
  • Page 12 – Do not put your fingers in or near the blower; Deflector; Setting vertical angle of air flow; NOTE ON LOUVER ANGLES; Setting Angle of Air Flow
  • Page 13 – Cleaning Your Air Filter; Care and Maintenance
  • Page 15 – Common Issues; Issue; Troubleshooting; A rushing air sound may occur when the louver resets its position.; SAFETY PRECAUTIONS; The power cord is damaged or abnormally warm
  • Page 16 – Problem
  • Page 18 – L iq u id sid e
  • Page 19 – Installation Summary - Indoor Unit; Select Installation Location; Wrap Piping and Cable
  • Page 20 – NOTE ON ILLUSTRATIONS; Unit Parts
  • Page 21 – DO NOT; install unit in the following; NOTE FOR CONCRETE OR BRICK WALLS:; Indoor Unit Installation
  • Page 22 – Step 3: Drill wall hole for connective piping; MOUNTING PLATE DIMENSIONS; When drilling the wall hole, make sure to; Type A
  • Page 23 – Step 4: Prepare refrigerant piping; Based on the position of the wall hole relative; Connect Drain Hose; NOTE ON PIPING ANGLE; Connect drain hose; PLUG THE UNUSED DRAIN HOLE
  • Page 24 – NOTE
  • Page 25 – DO NOT MIX UP LIVE AND NULL WIRES; This is dangerous, and can cause the air; NOTE ABOUT WIRING; Indoor Unit
  • Page 26 – UNIT IS ADJUSTABLE
  • Page 27 – below; Outdoor Unit Installation
  • Page 28 – If the drain joint comes with a rubber seal; Insert the drain joint into the hole in the base; If the drain joint doesn’t come with a rubber; IN COLD CLIMATES; Air inlet
  • Page 29 – Unit Model
  • Page 30 – Step 4: Connect signal and power cables; USE THE RIGHT CABLE; PAY; ATTENTION TO LIVE WIRE; CHOOSE THE RIGHT CABLE SIZE
  • Page 31 – let substances or gases other than the specified; DO NOT DEFORM PIPE; Model; Refrigerant Piping Connection
  • Page 32 – Step 4: Connect pipes; MINIMUM BEND RADIUS; Instructions for Connecting Piping to; Step 3: Flare pipe ends; PIPING EXTENSION BEYOND FLARE FORM; Outer Diameter of
  • Page 33 – Torque Requirements; Instructions for Connecting Piping to Outdoor Unit; TORQUE REQUIREMENTS; Tightening Torque; DO NOT USE EXCESSIVE TORQUE; torque requirements shown in the table above.
  • Page 34 – Preparations and Precautions; BEFORE PERFORMING EVACUATION; Evacuation Instructions; OPEN VALVE STEMS GENTLY; Air Evacuation
  • Page 35 – Note on Adding Refrigerant; mix refrigerant types.; ADDITIONAL REFRIGERANT PER PIPE LENGTH; Connective Pipe
  • Page 36 – Electrical Safety Checks; Electrical and Gas Leak Checks
  • Page 37 – Test Run Instructions; List of Checks to Perform
  • Page 38 – Instructions for packing and unpacking the unit:; Please keep all packaging items if you may need in the future.; Packing and unpacking the unit
  • Page 39 – Advantage Series; Consult with the sales agency or manufacturer for details.; INSTALLATION LOCATION:
Loading the manual

The Advantage Series is

NOT

designed for amateur installation.

Installation

SHOULD

be performed by an authorized technician.

Please read this manual carefully before installation and keep it for future reference.

Installation Manual

Advantage Series

Due to updates and constantly improving performance, the information and instructions within this

manual are subject to change without notice. Please visit www.mrcool.com/documentation to

ensure you have the latest version of this manual.

Version Date:

0

9-19

-23

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Unit Specifications and Features; Owner’s Manual; Table of Contents; Safety Precautions

Unit Specifications and Features ...........................................................07 Owner’s Manual Table of Contents Safety Precautions ...............................................................................03 Care and Maintenance .....................................................

Page 3 - Installation Manual

Installation Manual Accessories .........................................................................................17 Unit Parts ............................................................................................19 Indoor Unit Installation ................................................

Page 4 - Read Safety Precautions Before Operation and Installation; WARNING; or MrCool®; Do not; CLEANING AND MAINTENANCE WARNINGS; Do not; WARNING; This symbol indicates the possibility; CAUTION; This symbol indicates the possibility of

Safety Precautions Read Safety Precautions Before Operation and Installation The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION . Incorrect installation due to ignoring instructions can cause serious damage or injury. Safety Precautions   Page 3 WARNING Th...

Other MRCOOL Air Conditioners Models

All MRCOOL Air Conditioners