INSTALLATION NOTICE FOR NO-VAC™ QUICK CONNECT® LINE SET
KINK RESISTANT, PRECHARGED, SIMPLE SECURE QUICK CONNECT, 100% CONNECTION GUARANTEE
www.mrcool.com
v05-30-2019
Please read carefully and follow the instruc�ons as below
ⱡ
:
F1
to M1: Smaller connec�on (3/8”)
1.
Take out matching male connectors M1 and M2.
2.
Remove
protec�ve cap with the copper gasket at each stop valve on the condenser
and ensure the threads are clean and complete.
3.
Tighten
the
M1
connector to the
stop valve *1
with a �ghtening force of 50N.
Tighten
the
M2
connector to the
stop valve *2
with a �ghtening force of 70N.
4.
Repeat
step 3 for
INDOOR UNIT
at the other end of the
LINE SET
.
5.
Unroll and route the
LINE SET
between the
INDOOR UNIT
(Handler) and the
OUTDOOR UNIT
(Condenser).
6.
Remove
the protec�ve caps of the valves at both ends of the
LINE SET.
Verify
that all threads are clean and complete.
7.
Tighten
the
LINE SET F1
valve to the
M1 Connector
(a�ached in step 3) with a force
of
45N
.
Tighten
the
LINE SET F2
valve to the
M2 Connector
(a�ached in step 3) with a �ghtening force of
45N
.
8.
Repeat
this process for the
INDOOR UNIT
at the other end of the
LINE SET
.
Connec�ons must be made exactly as specified to avoid system leaks and /or da
mage
F2
to M2: Larger connec�on (3/4”)
9.
At the
OUTDOOR UNIT remove
the
protec�ve cap
at the
stop valve switch
and
open
the
stop valve
with a hex wrench to
run the refrigera�on circuit.
If
there is any fizz, grease or other
leakage
,
close
the valve
immediately
and
check
that
steps
3 and 7
were done properly.
Otherwise
, immediately
apply soapy water
for micro-leakage detec�on. Soak the joints using
a sponge or spray bo�le.
If any bubbles form
,
close
the valve
immediately
and
check
that
steps 3 and 7
were done properly.
10.
A�er
the correct connec�on,
re-�ghten
the stop valve’s
protec�on cap
and
cover
the M1, M2 and F1, F2 connec�ons
with the grey
insula�ng sleeve
to help
prevent condensa�on
.
ⱡ
Failure to follow the instructions provided could result in severe harm to you, this product, or other property.
The manufacturer, distributor, and seller are not responsible for any harm resulting from the failure to follow
instructions and the failure to follow these instructions will void any and all warranties express or implied.
NO-VAC™
QUICK CONNECT®
LINE SET
INDOOR UNIT
CONNECTOR M1 & M2
OUTDOOR UNIT
STEP 6
NO-VAC™ QUICK CONNECT® LINE SETs
allow you to connect indoor and outdoor units simpler, faster and safer.
NO-VAC™ QUICK CONNECT® LINE SETs
are an�-kink and pre-charged with refrigerant; suitable for most MRCOOL
®
installa�ons.
NO-VAC™ QUICK CONNECT® LINE SETs
are a double-sealing system with a unique automa�c safety valve that releases the
refrigerant only when the indoor and outdoor equipment is connected and sealed, thus avoiding any risk of leakage.
NO-VAC™ QUICK CONNECT® LINE SETs -
no need to vacuum, no need to add refrigerant.