MT692C

INSTALLATION INSTRUCTIONS

THESE INSTRUCTIONS MUST BE

LEFT WITH HOMEOWNER

T187, T188, T189, T190, T191, T628, 2320, 2325, 2339, 2370, 2375, 2389 Series
Models 12189, 12242, 12341, 12342, 62300, TL181, TL182, TL183, TL191

Measurements

These are shown in the drawings.

The depth measurement is critical. Use the front face of the plaster ground as a reference point for the finished wall

position, including tile ( 1-3/4"[44mm] )

. The supply piping centerline should be a maxium of 2" (51mm) and a minimum of 1" (25mm) behind the wall surface.

Use thick wall handle extension kit 96945 for wall thickness 13/16" to 1-13/16". Use handle kit 96955 for wall thickness 1-13/16" to 2-13/16".

Available with and without stops.

Connections are either 1/2 inch I.P.S. pipe or 1/2 inch copper sweat connections.

If the Moen Slip Fit spout is used, a 1/2 inch copper drop and lookout may be used.

POSI-TEMP

TUB AND SHOWER VALVES

Always turn water off before disassembling the valve. Open valve handle to relieve water
pressure and to insure that complete water shut-off has been accomplished.

Before turning water on during either rough-in or trim-out, make sure that cartridge retainer clip is in place.

The cartridge and retainer clip were properly installed and tested before leaving the factory. Although it is unlikely, it is never-

theless possible that through the handling of the valve by any number of persons the retainer clip may not be properly installed.
This should be carefully checked at time of rough-in and trim-out. If the retainer clip is not properly installed, water pressure

could force the cartridge out of the casting. Personal injury or water damage to the premises could result.

RETAINER

CLIP

CAUTION:

Visit Moen's Web Site at www.moen.com

WALL LINE

FACE OF STUD

1-3/4" (44mm)

2-5/16" (59mm) MAX (IPS)
2-3/16" (56mm) MAX (CC)

ESCUTCHEON

SHOWER 45" (1143mm) to 48" (1219mm)

32" (813mm) FOR TUB/SHOWER

COMBINATIONS AND TUB

MODELS ONLY

PLASTER GROUND

KEY STOP

TEMPERATURE

LIMIT STOP

KNOB

HANDLE

KNOB

SCREW

CAP

SCREW

HANDLE

SCREW

HANDLE

ADAPTER

HANDLE

SCREW

KNOB CAP

PLUG

BUTTON

LEVER

HANDLE

FINISHED WALL

SURFACE

STOP

TUBE

WASHER

HANDLE ASSEMBLIES

6'6"

(1981mm)

FLOOR

TUB SPOUT

IMPORTANT: SEE FLUSHING INSTRUC-
TIONS PAGE 2

A

B

C

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CAUTION; Stop Operation; MAKE SURE ALL WATER SUPPLIES ARE OFF.; Flushing

MT692C WITHOUT STOPS WITH STOPS 7" 7" SHOWER SHOWER SUPPLY TUB TUB SUPPLY SUPPLY 2-3/4" C.C. & I.P.S. 2-5/16" C.C. & I.P.S. 4-13/16" C.C. 4-5/16" NOMINAL 4-1/2" PLASTER GROUND SIZE AND WALL OPENING C.C. I.P.S. CLAMPSCREW CAUTION This valve is equipped with the Moe...

Page 3 - Disassembly

RETAINER CLIP CARTRIDGE NOTCH WASHER STOP TUBE KEY STOP TEMPERATURE LIMIT STOP KNOB HANDLE HANDLE ADAPTER CAP SCREW HANDLE SCREW HANDLE SCREW KNOB INSERT PLUG BUTTON HOT INLETFORWARD COLD INLET TO REAR INSTALL WITH CARTRIDGE STEM NOTCH DOWN TOP VIEW CAUTION: CARTRIDGE MUST BE INSTALLED WITH HOT &...

Page 4 - Trim; MAKE SURE ALL WATER SUPPLIES ARE OFF; TO REMOVE STOP VALVE; Removal of stop valve:; Not for use with Moentrol valves.; HELPLINE: Call our toll free Helpline number,; Reversed Rough-In Where Hot and Cold Positions Are Reversed:

MT692C NOV. 02 Trim MAKE SURE ALL WATER SUPPLIES ARE OFF TO INSTALL TRIM AFTER ROUGH-IN Slide the flange onto the long end of the shower arm. Wrap both ends of shower arm withthread seal tape and screw long end of shower arm into pipe ell inside the wall. Do not installthe showerhead. Install tub sp...