Page 2 - Install with confidence.; ioDIGITAL; cUPC with applicable standards ASSE 1016 and
2 Install with confidence. Moen has created this useful guide to assist you when installing a Moen ® Vertical Spa. You’ll find detailed guidelines, color-coded piping diagrams and FAQs for some of the most popular configurations. For additional information not contained within this general guide, re...
Page 3 - NO. Hot and cold inlets will have to be
3 6. Will the digital valves work with existing showerheads, hand showers and body sprays? Yes, the ioDIGITAL system works with all Moen fixtures. 7. Will the valve fit within a regular 2" x 4" framed wall? Yes. 8. Does the valve need to have ventilation? No. The valve should be mounted in a...
Page 4 - GFCI; This configuration; Optional remote
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested. Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas. 4 One-Wall ioDIGITAL ™ 3/4" ioDIGITAL ™ 3/4" de pulgada en una pared GFCI back of...
Page 5 - Arrow on volume control; ExactTemp
78" 48" 40" HOT WATER INLET Entrada de agua caliente COLD WATER INLETEntrada de agua fría 16" Arrow on volume control valve should always point in direction of flow. La flecha en la válvula de control de volumen deberá siempre apuntaren ladireccióndelflujo. Always cap the tub port wh...
Page 6 - A pressure-balancing loop
got orig. file, but need orig. graphics. mary ann? All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested. Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas. 6 Vertical spa trim is compatible with...
Page 16 - Three -Wall ioDIGITAL
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested. Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas. 16 GFCI back of valve faces into shower D C B A 78" HOT WATER INLET Entrada de agua c...
Page 17 - Three -Wall ExactTemp
78" 54" 34" 48" HOT WATER INLET Entrada de agua caliente COLD WATER INLETEntrada de agua fría 8" 8" 40" Three -Wall ExactTemp ® 3/4" ExactTemp ® 3/4" de pulgada en tres paredes BODY SPRAYS: A pressure-balancing loop must always be used with body sprays to allow fo...
Page 18 - -function transfer valve
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested. Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas. Vertical spa trim is compatible withtheM•PACT ® Common Valve System. Todos los componente...
Page 20 - used with; Note: This configuration
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested. Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas. *Minimum of 40 psi recommended for this configuration. *Se recomienda un mínimo de 40 psi...
Page 21 - used with 3-function
When using a tub spout with a mixing valve and diverter, plumb the flow valve bottom outlet to the twin ell front vertical inlet. Plug the top outlet of the flow valve. Plumb the twin ell rear vertical outlet to the diverter. Plumb the twin ell front horizontal outlet to the tub spout. Cuando se usa...
Page 22 - Always cap tub port
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested. Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas. *Minimum of 40 psi recommended for this configuration. *Se recomienda un mínimo de 40 psi...