Mitsubishi SEZ-KD71VAQ- User Manual

Mitsubishi SEZ-KD71VAQ

Mitsubishi SEZ-KD71VAQ– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
Page: / 74

Table of Contents:

  • Page 2 – COMBINATION OF INDOOR AND OUTDOOR UNITS; Heat pump type
  • Page 3 – TECHNICAL CHANGES; Refrigerant; INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT; materials are required. Refer to the table below.; NOTE; The conversion factor is:
  • Page 4 – Tools dedicated for the air conditioner with R410A refrigerant; Conversion chart of refrigerant temperature and pressure; : The unit of pressure has been changed to MPa on the
  • Page 5 – Flaring work and flare nut; Refrigerant piping; Specifications
  • Page 6 – PART NAMES AND FUNCTIONS; Model; Drain socket
  • Page 7 – SPECIFICATION; Compressor
  • Page 8 – Specifications and rating conditions of main electric parts
  • Page 9 – NOISE CRITERIA CURVES
  • Page 10 – OUTLINES AND DIMENSIONS; REQUIRED SPACE
  • Page 11 – Service panel; Drain holes
  • Page 13 – WIRING DIAGRAM
  • Page 14 – INVER; MC; MF
  • Page 17 – REFRIGERANT SYSTEM DIAGRAM
  • Page 20 – MAX. REFRIGERANT PIPING LENGTH; Outdoor unit; MAX. HEIGHT DIFFERENCE
  • Page 21 – ACTUATOR CONTROL; -3. Relation between main sensor and actuator; : The 4-way valve reverses for 5 seconds
  • Page 22 – CHANGE IN DEFROST SETTING; TROUBLESHOOTING; Troubleshooting procedure; Housing point; SERVICE FUNCTIONS
  • Page 24 – CHECK button
  • Page 34 – A How to check inverter/compressor; C Check of compressor
  • Page 35 – D Check of compressor winding; E Check of compressor operation time; F Check of outdoor thermistors
  • Page 36 – H Check of outdoor fan motor
  • Page 37 – (For wireless remote controller use model)
  • Page 38 – J Check of LEV
  • Page 39 – L How to check miswiring and serial signal error
  • Page 41 – Electromagnetic noise enters into TV sets or radios
  • Page 42 – Check of power supply; Turn on power supply.
  • Page 46 – Yes
  • Page 47 – Check of outdoor thermistors; When thermistor is abnormal.; Check of outdoor fan motor
  • Page 48 – Check of HPS; Infinity; When the operation frequency does not go up from lowest frequency.; Check of current-limiting resistor
  • Page 51 – g Check of outdoor thermistors; Unit operates COOL mode even if it is set to HEAT mode.
  • Page 53 – k Check of LEV
  • Page 55 – m How to check miswiring and serial signal error
  • Page 56 – n Electromagnetic noise enters into TV sets or radios
  • Page 57 – Back side of unit
  • Page 59 – LED
  • Page 63 – DISASSEMBLY INSTRUCTIONS; Removing the cabinet
  • Page 64 – Photo 3
  • Page 65 – Removing outdoor fan motor
  • Page 67 – Photo 4
  • Page 68 – for; Photo 9; Propeller; OPERATING PROCEDURE; (6) Pull out the outdoor heat exchanger temperature thermistor; Photo 7; Discharge temperature thermistor
  • Page 69 – Removing the compressor and 4-way valve; Recover gas from the pipes until the pressure; Removing the reactor; Screws of the reactor
  • Page 70 – Turn OFF power supply before disassembling.; Screws of the top panel
  • Page 71 – and outdoor heat exchanger temperature thermistor); Earth wires
Loading the manual

TECHNICAL & SERVICE MANUAL

No.OCH472

REVISED EDITION-A

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS

R410A

Outdoor unit
[Model names] [Service

Ref.]

SUZ-KA25VA2

SUZ-KA25VA2.TH

SUZ-KA35VA2

SUZ-KA35VA2.TH

SUZ-KA50VA2

SUZ-KA50VA2.TH

SUZ-KA60VA2

SUZ-KA60VA2.TH

SUZ-KA71VA2

SUZ-KA71VA2.TH

CONTENTS

1. COMBINATION OF INDOOR AND OUTDOOR UNITS....... 2

2. TECHNICAL CHANGES .................................... 3

3. PART NAMES AND FUNCTIONS......................6

4. SPECIFICATION................................................. 7

5. NOISE CRITERIA CURVES............................... 9

6. OUTLINES AND DIMENSIONS........................ 10

7. WIRING DIAGRAM........................................... 13

8. REFRIGERANT SYSTEM DIAGRAM.............. 17

9. ACTUATOR CONTROL.................................... 21

10. SERVICE FUNCTIONS..................................... 22

11. TROUBLESHOOTING...................................... 22

12. DISASSEMBLY INSTRUCTIONS..................... 63

Indication of
model name

NOTE:

This service manual describes technical data of the
outdoor units.
RoHS compliant products have <G> mark on the spec
name plate.
For servicing of RoHS compliant products, refer to the
RoHS Parts List.

HFC

utilized

R410A

SUZ-KA25VA2.TH
SUZ-KA35VA2.TH

September 2011

PARTS CATALOG (OCB472)

Revision:
• Errors in "11.

TROUBLESHOOTING"
have been corrected in
REVISED EDITION-A.

• Some descriptions have

been modified.

• Please void OCH472.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - COMBINATION OF INDOOR AND OUTDOOR UNITS; Heat pump type

2 1 COMBINATION OF INDOOR AND OUTDOOR UNITS Heat pump type Outdoor unit SUZ- SLZ-KA25VA(L).TH SLZ-KA35VA(L).TH SLZ-KA50VA(L).TH SLZ-KA25VAQ.TH SLZ-KA35VAQ.TH SLZ-KA50VAQ.TH SEZ-KD25VA(L).TH SEZ-KD35VA(L).TH SEZ-KD50VA(L).TH SEZ-KD60VA(L).TH SEZ-KD71VA(L).TH SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ....

Page 3 - TECHNICAL CHANGES; Refrigerant; INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT; materials are required. Refer to the table below.; NOTE; The conversion factor is:

3 2 TECHNICAL CHANGES Refrigerant oil Refrigerant New refrigerant R410A HFC-32: HFC-125 (50%:50%) Pseudo-azeotropic refrigerant Not included A1/A1 72.6 -51.4 1.557 64 Non combustible 0 1730 From liquid phase in cylinder Possible Incompatible oil NoneNone Previous refrigerant R22 R22 (100%) Single re...

Page 4 - Tools dedicated for the air conditioner with R410A refrigerant; Conversion chart of refrigerant temperature and pressure; : The unit of pressure has been changed to MPa on the

4 R410A tools Can R22 tools be used? Gas leak detector R410A has high pressures beyond the measurement range of existing gauges. Port diameters have been changed to prevent any other refrigerant from being charged into the unit. Hose material and cap size have been changed to improve the pressure re...

Other Mitsubishi Models