  • Page 2 – Use the speci; Never use any refrigerant other than that specified.
  • Page 3 – TECHNICAL CHANGES; and
  • Page 4 – ACCESSORIES; PART NAMES AND FUNCTIONS; Model
  • Page 5 – NOTE; SPECIFICATION; Specifications and rated conditions of main electric parts
  • Page 6 – NOISE CRITERIA CURVES; Test conditions
  • Page 7 – OUTLINES AND DIMENSIONS
  • Page 8 – WIRING DIAGRAM
  • Page 9 – REFRIGERANT SYSTEM DIAGRAM
  • Page 10 – How to modify the remote controller P.C. board; Table 1; SERVICE FUNCTIONS
  • Page 11 – Operation; How to disable “AUTO RESTART FUNCTION”
  • Page 12 – WIRELESS REMOTE CONTROLLER; MICROPROCESSOR CONTROL; INDOOR UNIT DISPLAY SECTION; Coil frost prevention
  • Page 13 – -5. AUTO CHANGE OVER ··· AUTO MODE OPERATION
  • Page 14 – OUTDOOR UNIT: MXZ series; AUTO
  • Page 15 – PROGRAM TIMER
  • Page 16 – How to set the weekly timer
  • Page 17 – How to cancel operation
  • Page 18 – How to replace batteries; TROUBLESHOOTING
  • Page 20 – Indoor unit failure mode table
  • Page 24 – A Check of indoor fan motor
  • Page 26 – C Check of indoor P.C. board and indoor fan motor
  • Page 27 – D How to check miswiring and serial signal error; MUZ Type
  • Page 28 – MXZ Type
  • Page 29 – E Electromagnetic noise enters into TV sets or radios
  • Page 31 – Removing the panel; DISASSEMBLY INSTRUCTIONS; Removal procedure
  • Page 32 – Remove the indoor electrical box
  • Page 33 – Removing the nozzle assembly; Photo 4
  • Page 34 – Removing the indoor fan motor, the indoor coil; Copyright 2011 MITSUBISHI ELECTRIC CORPORATION
Loading the manual

CONTENTS

1. TECHNICAL CHANGES ··································· 3
2. PART NAMES AND FUNCTIONS ····················· 4
3. SPECIFICATION ················································ 5
4. NOISE CRITERIA CURVES ······························ 6
5. OUTLINES AND DIMENSIONS ························ 7
6. WIRING DIAGRAM ············································ 8
7. REFRIGERANT SYSTEM DIAGRAM ··············· 9
8. SERVICE FUNCTIONS ··································· 10
9. MICROPROCESSOR CONTROL ··················· 12

10. TROUBLESHOOTING ····································· 18
11. DISASSEMBLY INSTRUCTIONS ···················· 31

SPLIT-TYPE AIR CONDITIONERS

SERVICE MANUAL

INDOOR UNIT

PARTS CATALOG (OBB600)

NOTE:

RoHS compliant products have <G> mark on the spec name plate.

Models

MSZ-SF25VE -

E1

MSZ-SF35VE -

E1

MSZ-SF25VE -

E2

MSZ-SF35VE -

E2

MSZ-SF42VE -

E1

MSZ-SF50VE -

E1

MSZ-SF42VE -

E2

MSZ-SF50VE -

E2

MSZ-SF25VE -

EN1

MSZ-SF35VE -

EN1

MSZ-SF25VE -

EN2

MSZ-SF35VE -

EN2

MSZ-SF42VE -

EN1

MSZ-SF50VE -

EN1

MSZ-SF42VE -

EN2

MSZ-SF50VE -

EN2

No. OBH600

REVISED EDITION-B

Revision B:

• "How to check miswiring and serial signal error"

for MUZ type has been added.

• The description about "Low standby power

control" has been added to "TECHNICAL

CHANGES".

Please void OBH600 REVISED EDITION-A.

Outdoor unit service manual
MUZ-SF·VE(H) Series (OBH629)
MXZ-C·VA Series (OB584)
MXZ-D·VA Series (OBH626)
MXZ-8B Series (OCH480)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Use the speci; Never use any refrigerant other than that specified.

2 <Preparation before the repair service> Prepare the proper tools. Prepare the proper protectors. Provide adequate ventilation. After stopping the operation of the air conditioner, turn off the power-supply breaker and remove the power plug. Discharge the capacitor before the work involving t...

Page 3 - TECHNICAL CHANGES; and

3 TECHNICAL CHANGES 1 MSZ-SF25VE- E1 MSZ-SF25VE- EN1 MSZ-SF35VE- E1 MSZ-SF35VE- EN1 MSZ-SF42VE- E1 MSZ-SF42VE- EN1 MSZ-SF50VE- E1 MSZ-SF50VE- EN1 1. New model MSZ-SF25VE- E1 MSZ-SF25VE- E2 MSZ-SF25VE- EN1 MSZ-SF25VE- EN2 MSZ-SF35VE- E1 MSZ-SF35VE- E2 MSZ-SF35VE- EN1 MSZ-SF35VE- EN2 MSZ-SF42VE- E1 MS...

Page 4 - ACCESSORIES; PART NAMES AND FUNCTIONS; Model

4 ACCESSORIES MSZ-SF25VE MSZ-SF35VE MSZ-SF42VE MSZ-SF50VE PART NAMES AND FUNCTIONS 2 Model MSZ-SF25VE MSZ-SF35VE MSZ-SF42VE MSZ-SF50VE Installation plate 1 Installation plate fi xing screw 4 × 25 mm 5 Remote controller holder 1 Fixing screw for 3.5 × 16 mm (Black) 2 Battery (AAA) for remote controll...