Controling the projector using a personal computer
This projector can be controlled by connecting a personal computer with RS-232C terminal.
PC-controllable functions :
• Turning the power ON or OFF
• Changing input signals
• Inputting commands by pressing the buttons on the control panel and remote control
• Menu setting
Connection
REMOTE
IN
REMOTE
OUT
INPUT 1
INPUT 2
R/P
R
B/P
B
G/Y
H/H
V
V
AUDIO
IN
AUDIO
OUT
Y
C
RS-232C
RS-232C/MOUSE
USB
S-VIDEO
VIDEO
2
VIDEO
1
L
AUDIO
R
MAIN
AC IN
to RS-232C/MOUSE terminal
or RS-232C terminal
to SERIAL port
8P
D-SUB 9P
RS-232C cable
Important:
• Make sure that your computer and projector are turned off before connection.
• Turn on the projector after the computer is started up.
(If you do not follow this instruction, the Comport may not function.)
• There are two RS-232C terminals on the projector. You can use either of them.
• Adapters may be necessary depending on the PC connected to this projector. Contact your dealer for details.
PROTOCOL
RS-232C
BAUD RATE
9600 [bps]
DATA LENGTH
8 [bits]
PARITY BIT
NONE
STOP BIT
1 [bit]
FLOW CONTROL
NONE
This projector uses RXD, TXD and GND lines for RS-232C control.
For RS-232C cable,the reverse type cable should be used.
2) Control command diagram
The command consists of the address code, function code, data code, and end code. The length of the command
varies among the functions.
Address code
Function code
Data code
End code
HEX
30h 30h
Function
Data
0Dh
ASCII
'0' '0'
Function
Data
[Address code]
30h 30h (In ASCII code, '0' '0') fixed.
[Function code]
A code of each fixed control move.
[Data code]
A code of each fixed control data (number) and not always indicated.
[End code]
0Dh (In ASCII code, '
') fixed.
LCD Projector
XL5950U / XL5950LU / XL5900U / XL5900LU
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 3) Control sequence (1) Send the command from the personal computer to the projector. (The commands shall be sent at intervals of at least 400ms.) (2) The projector will send a return command 400ms* after it receives an end code. If the command is not received correctly, the projector will not sen...
3 Sending commands Status code from Description from the PC, etc. the projector 30 30 72 35 34 0D Command operating the same '0' '0' 'r' '5' '4' ' ' as the MENU button 30 30 72 35 34 0D Command receipt confirmation '0' '0' 'r' '5' '4' ' ' (Command echo back) [Example] When displaying the MENU select...
4 10) Menu setting commands (Not executable in stand-by mode, while the Splash screen is projected or the MUTE is executed.) The menu setting commands are used for the menu setting of this projector. If the personal computer sends thecommand without attaching the data code, the projector attaches to...