Mitsubishi Electric U1 - Manual

Mitsubishi Electric U1

Mitsubishi Electric U1 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 3 – Piping
  • Page 4 – SPECIFICATION
  • Page 5 – Test condition; OPERATING RANGE
  • Page 6 – REQUIRED SPACE; OUTLINES AND DIMENSIONS
  • Page 7 – WIRING DIAGRAM
  • Page 9 – REFRIGERANT SYSTEM DIAGRAM
  • Page 10 – MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
  • Page 11 – DATA
  • Page 12 – Cooling; Heating
  • Page 16 – -5. CAPACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY
  • Page 18 – ACTUATOR CONTROL; -3. Relation between main sensor and actuator
  • Page 19 – SERVICE FUNCTIONS
  • Page 20 – TROUBLESHOOTING; Before troubleshooting, check the following; components for bursting and discoloration.; Lead wiring
  • Page 21 – Outline of the function
  • Page 22 – Operational procedure
  • Page 27 – MUZ
  • Page 28 – A How to check inverter/ compressor
  • Page 29 – B Check of outdoor thermistors
  • Page 31 – Outdoor unit does not operate.; D Check of outdoor fan motor
  • Page 33 – H How to check miswiring and serial signal error
  • Page 34 – The operation frequency does not go up from lowest frequency.; I Check of HPS
  • Page 35 – J Electromagnetic noise enters into TV sets or radios
  • Page 38 – Outdoor power board; Connect to the earth
  • Page 39 – Removing the cabinet; Photo 2; DISASSEMBLY INSTRUCTIONS
  • Page 40 – power board; Screws of the relay panel; Photo 6; Propeller
  • Page 41 – (5) Pull out the outdoor heat exchanger temperature thermistor; Removing outdoor fan motor
  • Page 42 – Removing the compressor and 4-way valve; Recover gas from the pipes until the pressure; Removing the reactor; Welded parts of 4-way valve
  • Page 44 – Copyright 2008 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD; TM
Loading the manual

SERVICE MANUAL

CONTENTS

1. TECHNICAL CHANGES ··································· 3
2. PART NAMES AND FUNCTIONS ····················· 3
3. SPECIFICATION ················································ 4
4. OUTLINES AND DIMENSIONS ························ 6
5. WIRING DIAGRAM ············································ 7
6. REFRIGERANT SYSTEM DIAGRAM ··············· 9
7. DATA ·································································11
8. ACTUATOR CONTROL ··································· 18

9. SERVICE FUNCTIONS ··································· 19
10. TROUBLESHOOTING ····································· 20
11. DISASSEMBLY INSTRUCTIONS ···················· 39

Wireless type
Models

MUZ-D30NA
MUZ-D30NA-

U1

MUZ-D36NA
MUZ-D36NA-

U1

MUY-D30NA
MUY-D36NA

OUTDOOR UNIT

Indoor unit service manual

MSZ-D•NA Series (OBH501)
MSY-D•NA Series (OBH501)

NOTE:

RoHS compliant products have <G> mark on the spec name plate.

TM

HFC

utilized

R410A

No. OBH502

PARTS CATALOG (OBB502)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Piping

33 1 TECHNICAL CHANGES MUZ-D30NA MUZ-D30NA - U1 MUZ-D36NA MUZ-D36NA - U1 MUY-D30NA MUY-D36NA 1. New model PART NAMES AND FUNCTIONS 2 MUZ-D30NA MUY-D30NA Piping Air outlet Drain hose Drain outlet Air inlet (back and side) MUZ-D36NA MUY-D36NA

Page 4 - SPECIFICATION

44 3 SPECIFICATION Item Model MSZ-D30NA MSY-D30NA MSZ-D36NA MSY-D36NA Capacity Rated(Minimum~Maximum) Cooling 1 Btu/h 30,700 (9,800 ~ 30,700) 30,700 (9,800 ~ 30,700) 32,000/33,200 (9,800 ~ 32,000) / (9,800 ~ 33,200) 33,200/34,600 (9,800 ~ 33,200) / (9,800 ~ 34,600) Heating 47 1 Btu/h 32,600 (8,700 ~...

Page 5 - Test condition; OPERATING RANGE

55 Test condition ARI Mode Test Indoor air condition Outdoor air condition Dry bulb (°F) Wet bulb (°F) Dry bulb (°F) Wet bulb (°F) SEER (Cooling) "A" Cooling Steady State at rated compressor Speed 80 67 95 (75) "B-2" Cooling Steady State at rated compressor Speed 80 67 82 (65) "B...