Page 2 - C O N T E N T S; Mitsubishi Electric; comfortable living and working environments.
M Series S Series P Series Multi System Line Up Mitsubishi Electric's Main Technology High End Models Icons 3-6 7-14 15-24 25 26-39 40-42 43-73 74-90 C O N T E N T S Mitsubishi Electric , s Long history proves excellence in air conditioning with the leading-edge technology. With 50 years experience ...
Page 3 - Multi; Series; INVERTER Models; series
P75 P77 P77 P77 P77 P77 P87 P87 P87 P87 P87 P87 Wall Mounted Ceiling Suspended Floor Standing Ceiling Concealed Cassette ■ INVERTER Models ● Heat Pump type ■ FIXED-SPEED Models ● Cooling Only type MXZ-8A140VA Multi Series up to 8 indoor units 14.0kW MXZ-4A80VA up to 4 indoor units 8.0kW MXZ-4A71...
Page 4 - POWER INVERTER Models; STANDARD INVERTER Models
6 ■ FIXED-SPEED Models 4 way Cassette C e i l i n g C o n c e a l e d Wall mounted Ceiling Suspended Floor Standing PS(H) series PC(H)-HA series for Professional Kitchen PC(H)-GA series PK(H)-FAL series PEH series R407C R407C PE(H)D-GA series PE(H)D-EA series PL(H) series 3HP 4HP 5HP 6HP 8HP 10HP 7....
Page 5 - “Econo Cool” mode; This diagram illustrates the merits of PAM Control.; Energy Efficiency Stays Strong; Inverter & Energy Saving Technology; Noise; Energy
2002 JSRAE TECHNOLOGY AWARD 2002 JSRAE TECHNOLOGY AWARD Japan Society of Refrigerating and Air Conditioning Engineers DC compressor motor ( rotor ) Neodymium magnets The reluctance DC motor has a rotor equipped with powerful neodymium magnets. The magnetic torque produced by the neodymium magnets an...
Page 6 - Only; Silent Operation; New HAB Refrigerant Oil; Mitsubishi Electric’s Cleaning-Free Technology; Silent Operation Technology; DAY; in; NIGHT; Indoor Unit; dB; Only; Advantages; For installer
dB Only MSZ-FA/GA25 1/2 noise Operation has been made very silent by improvements to the design of the fan blades and the new grille shape. The outdoor unit is even more silent when o u t s i d e t e m p e r a t u r e d r o p s a s i t automatically switches to low-noise mode to reduce operating noi...
Page 7 - Operation Control Function; The setting of the upper and lower limit temperature is; Effective in energy saving control; Economical; Control Technology; about; Energy Saving; Easy Maintenance Function; Discharge temperature 64 ̊C
PAR-21MAA The air conditioning operation can be switched off automatically thus preventing waste operation. The set time can be changed from 30 minutes to 4 hours at 30-minute intervals. Operation Control Function Auto Off timer Operationlocking Equipped with the Long Awaited Weekly Timer Easy-to-re...
Page 8 - SYSTEM CONTROLS; For P series and S series Indoor Units
1 2 3 4 5 1-remote controller control Standard System 2-remote controller control With 2 remote controllers, control can be performed locally and remotely from 2 spots. Group Control One remote controller can control plural air conditioners simultaneously under a same setting. * The setting of the r...
Page 9 - Quick Clean; . Thanks to this advanced sensing; Auto Front Panel; mm; FA Series; AREA
Plasma Deodorizing Filter The newly equipped "Plasma Deodorizing Filter" provides state- of-the-art deodorization-decomposition and elimination of harmful chemical substances at the nanolevel (1/1,000,000 of a millimeter). The key to high power deodorization of the most unpleasant odors* 1 i...
Page 10 - MFZ Series; m m; Smarter Control, with a Single Remote Controller; bacteria; i save
MFZ Series For your Living Room, or Bed Room.The latest Mitsubishi innovation – floor standing air-conditioner sophisticated in design, rich in function. i save mode Optimum Air Distribution Cleaner and Healthier Air Trouble-Free Installation and Maintenance Sophisticated Design Slim but Mighty Quie...
Page 11 - reduction; Less than half in the running current and the breaker size !!; -20 ̊C Heating is possible; Max Piping Length; Power Consumption; COP; Outdoor Units; Power Inverter; Indoor Units
Before replacement: Installed 8 years ago Model name PLH-3GKHB/ PUH-3YKA After replacement: Power Inverter Model name PLA-RP71AA/ PUHZ-RP71VHA Conditions of trial calculation ( according to Japan Refrigerant Association ) Power Inverter Non-Inverter (R407C) COP Outdoor Unit 3.5 3.0 2.25 3.60 3HP 2.6...
Page 12 - Standard Inverter; Day; Night; For Easier Installation; EER
Standard Inverter Our New Inverter Features Energy Saving, Compact Design, Light Weight, and Basic Performances as well. Pump down switch Pump down switch Indoor unit control circuit board SUZ-KA35VA SUZ-KA50/60/71VA PUHZ-P100 PUHZ-P125/140 To meet your interior or space designing, optimum indoor un...
Page 13 - MXZ series; Down weighted by; Compact Outdoor Units; Advantage of Power Multi System; Smaller MXZ 2, 3 and 4 ports; Cooling may be useful in; indoor
MXZ series Our Strengthened MXZ Lineup Provides a Quiet,Highly Efficient and Flexible Air Conditioning SystemFor All Your Air Conditioning Needs MXZ-A14/18WV MXZ-2A Down weighted by 12 kg Downsized by 30 % Compact Outdoor Units 40 kg NEW 10~15m 30~70m 30~70m 285 800 330 840 640 550 OutdoorUnit Branc...
Page 14 - SWING; Weekly; MXZ; cons
25 DC Inverter PAM Control EER A COP A Econo Cool AREA Only 21 dB SWING HORIZONTAL SWING HORIZONTAL SWING VERTICAL AUTO VANE Wide Long VERTICALAIR FLOW Anti-Allergy Enzyme Catechin Fresh Air Intake Anti-Mold Air-Cleaning Deodorizing Auto Panel Flat Panel 270mm Compact Glossy White 2 x 2 Size Compact...
Page 15 - HEAT PUMP; Wall mounted Type Specifications; Remote
27 Wall mounted Type Specifications HEAT PUMP Type Model Name Indoor Unit Outdoor Unit Power Supply [ V, Phase, Hz, Source] MSZ-FA25VA MSZ-FA25VA MUZ-FA25VA 2.5 0.9 - 3.2 0.595 4.20 A 21 - 29 - 36 - 42 46 4.2 - 9.9 3.2 0.9 - 5.0 0.735 4.35 A 21 - 29 - 36 - 42 46 4.4 - 10.2 6.5 33 298 780 198 10 550 ...
Page 18 - Cooling Only
Wall mounted Type Specifications Cooling Only Type Model Name Indoor Unit Outdoor Unit Power Supply [ V, Phase, Hz, Source] MS-GA20VB MSC-GA20VB MU-GA20VB 2.3 - 0.715 3.22 A 25 - 31 - 36 45 7.9 - - - - - - - - 5.7 35 278 815 244 9 550 800 285 27 6.35 / 9.52 20 / 10 +21 ~ +43 - MS-GA25VB MSC-GA25VB M...
Page 22 - Ceiling Concealed Type Specifications; way Cassette Type Specifications; Remote Controller
HEAT PUMP SEZ-KC/KA series Ceiling Concealed Type Specifications Type Model Name Indoor Unit Outdoor Unit Power Supply [V, Phase, Hz, Source] SEZ-KC25VA SEZ-KC25VA SUZ-KA25VA 2.5 0.9 - 3.2 0.73 3.42 A 3.0 0.9 - 4.5 0.83 3.61 A 225 790 550 19 4.8 - 7.9 5 - 5 25 - 36 550 800 285 33 34.3 - 32.3 46 - 46...
Page 23 - -way Ceiling Cassette Type Specifications; POWER INVERTER
4-way Ceiling Cassette Type Specifications HEAT PUMP POWER INVERTER Type Indoor Unit Outdoor Unit Power Supply [V, Phase, Hz] PLA-RP35AA PUHZ-RP35VHA2 3.6 1.6 - 4.5 1.07 3.36 A 4.1 1.6 - 5.2 1.12 3.66 A 11 - 12 - 13 - 14 0 27 - 28 - 29 - 31 13 / - 16 / - 12.7 / 6.35 50 / 30 -5 ~ +46 -11 ~ +21 PLA-RP...
Page 25 - Wall Mounted Type Specifications
Ceiling Concealed Type Specifications HEAT PUMP Type Indoor Unit Outdoor Unit Power Supply [V, Phase, Hz] PEH-RP200MYA PUHZ-RP200YHA 19.0 10.0 - 22.4 7.28 2.61 D 22.4 10.0 - 25.0 6.98 3.21 C 428 1,380 650 70 48 - 60 50 / 150 45 - 49 (at 50Pa) 1,798 x 900 x 750 198 150 55(52) - 56 24 32 25.4 / 9.52 8...
Page 26 - Ceiling Suspended Type Specifications; for Professional Kitchen use
Ceiling Suspended Type Specifications HEAT PUMP Type Indoor Unit Outdoor Unit Power Supply [V, Phase, Hz] PCA-RP50GA PUHZ-RP50VHA2 4.7 2.3 - 5.4 1.67 2.81 C 5.5 2.5 - 6.6 1.71 3.22 C 210 1,000 680 27 10 - 11 - 12 - 13 0 37 - 38 - 40 - 42 45 13 / - 16 / - 50 / 30 - 5 ~ + 46 - 11 ~ + 21 PCA-RP50GA2 PU...
Page 27 - Floor Standing Type Specifications; STANDARD INVERTER
Floor Standing Type Specifications HEAT PUMP Type Indoor Unit Outdoor Unit Power Supply [V, Phase, Hz] PSA-RP71GA PUHZ-RP71VHA2 7.1 3.3 - 8.1 2.20 3.23 A 7.6 3.5 - 10.2 2.23 3.41 B 1,900 600 270 43 15 - 18 0 40 - 45 943 x 950 x 330(+30) 75 55 47(44) - 48 19 / - 25 / - 15.88 / 9.52 50 / 30 -5 ~ +46 -...
Page 31 - FIXED SPEED
PLH-P series 59 FIXED SPEED 24 - 25 - 27 - 30 0 37 - 40 - 43 - 45 1,350 950 330 + 30 131 100 25 24 - 25 - 27 - 30 0 37 - 40 - 43 - 45 1,350 950 330 + 30 131 100 25 VHA:230V - Single - 50Hz - Outdoor power Supply YHA:400V - Three - 50Hz - Outdoor power Supply 15.88 / 9.52 50 / 50 -5* 1 ~ +46 -11 ~ +2...
Page 35 - Ceiling Suspended Typee Specifications
Type Indoor Unit Outdoor Unit Power Supply [V, Phase, Hz] Cooling Heating Indoor Outdoor Breaker Size Ext. Piping Guaranteed Operating Range [Outdoor] Capacity Total Input EER Capacity Total Input COP Dimensions Weight [with Heater] * 2 Air Volume (Lo-Mi2-Mi1-Hi) External Static Pressure Sound Level...
Page 38 - PEH; system
Ceiling Concealed Type Specifications HEAT PUMP Type Indoor Unit Outdoor Unit Power Supply [V, Phase, Hz] PEH-RP200MYA PUH-P200MYA 20.9 7.92 2.64 D 23.7 7.82 3.03 D 428 1,380 650 70 16.6 50 / 150 53 (at 50Pa) 1,715 x 990 x 840 215 185 56 13.0 - 12.8 50 25.4 / 12.7 50 / 40 0 ~ +43 -12 ~ +15 PEH-RP250...
Page 39 - A Variety of Indoor Units; for example; Ceiling Concealed; PAC-AK30/50BC Branch Boxes Specifications; Piping Length and Height Differential
75 Branch Box A Variety of Indoor Units for example MSZ-GA22/25/35VA MSZ-FA25/35VA MSZ-GB50VA MSZ-GA60/71VA MFZ-KA25/35/50VA Consisting of 28 Models in 10 Types Allows Your Best Selection. Up to 8 indoor units can be connected. MXZ-8A140VA Ceiling Concealed Ceiling Cassette Wall Mounted Compact floo...
Page 40 - MXZ Specifications; Connectable indoor units; Combination table
Type (Inverter Multi Split Heat Pump) Model Name Outdoor Unit Power Supply [V, Phase. Hz, Source] Cooling Heating Max. Running Current Max. Total Capacity of all Indoor Units Outdoor Ext. Piping Guaranteed Operating Range [Outdoor] Running Current and Power Input figures are for Outdoor unit only. *...
Page 45 - MSX; MSX Specifications
87 MUX-2A28VB 1 OUT DOOR UNIT 2 INDOOR UNITS Multi-Split System MSC-GA20 MUX-2A59VB 1 OUT DOOR UNIT 2 INDOOR UNITS MSC-GA20 MSC-GA20 MSC-GA35 MUX-2A70VB 1 OUT DOOR UNIT 2 INDOOR UNITS MSC-GA35 MSC-GA35 MSC-GA25 MSC-GA25 MSC-GA25 MUX-3A60VB 1 OUT DOOR UNIT 3 INDOOR UNITS MSC-GA20 MSC-GA20 MSC-GA35 MS...
Page 46 - ndoor unit; Twin; Selection of Outdoor unit; rocedure of selection; All indoor units; - Combination pattern of indoor units; ) Automatic address setting for easy installation.
Mr.SLIM Multi - System Multiple (2,3 & 4) indoor units can be operated simultaneously with a single outdoor unit. Mr. SLIM Inverter (PUHZ-RP / PUHZ-P) Advantages of Mr.SLIM Multi - System S ystem example C ombination chart 71 100 35 x 2 50 x 2 125 60 x 2 140 71 x 2 50 x 3 200 100 x 2 60 x 3 50 x...
Page 47 - ccessories; Temperature conditions are based on JIS B8616; onditions for specifications; Refrigerant piping length 5M
A ccessories MSDD-50SR-E MSDD-50WR-E MSDD-50AR-E MSDD-50BR-E MSDT-111R-E SDT-112SA-E SDT-122SA-E MSDF-1111R-E PAC-SG72RJ-E PAC-SG73RJ-E PAC-SG74RJ-E PAC-SG75RJ-E PAC-SG76RJ-E PAC-493PI MAC-A454JP-E MAC-A455JP-E MAC-A456JP-E PAC-SG81DR-E PAC-SG82DR-E PAC-SG85DR-E PAC-AK350CVR-E MAC-888SG PAC-SF08SG-E...