Mitsubishi Electric PMFY-P12NBMU-E - Manual

Mitsubishi Electric PMFY-P12NBMU-E

Mitsubishi Electric PMFY-P12NBMU-E – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – FEATURES; Models; Indoor Unit; TECHNICAL CHANGES
  • Page 3 – PART NAMES AND FUNCTIONS; Guide vane; Returns air from room.; Filters; Wired remote controller
  • Page 4 – ̊F ̊C; Display Section
  • Page 5 – SPECIFICATION; Electric characteristic
  • Page 6 – Note : Refer to WIRING DIAGRAM for the supplied voltage.
  • Page 7 – Air capacity taken from outside; Operation in conjunction with duct fan (Booster fan); Whenever the indoor unit is operating, the duct fan; How to read curves
  • Page 8 – UNIT
  • Page 9 – OUTLINES AND DIMENSIONS
  • Page 10 – WIRING DIAGRAM
  • Page 12 – REFRIGERANT SYSTEM DIAGRAM; Gas pipe
  • Page 13 – MICROPROCESSOR CONTROL; To be continued to the next page
  • Page 14 – From the preceding page
  • Page 17 – Press the operation MODE button to display HEAT.
  • Page 20 – TROUBLE SHOOTING
  • Page 21 – Linear expansion valve; Operation summary of the linear expansion valve; Thermistor R
  • Page 22 – ; Linear expansion valve operation
  • Page 27 – DISASSEMBLY PROCEDURE; OPERATING PROCEDURE; Removing the intake grille; (2) Put your fingers on both ends of the air intake grille and let; Opening the air intake grille; of air intake grille, and pull down both; Removing the air intake grille; Be careful when removing heavy parts.; Photo 1; Figure 2
  • Page 28 – (5) Disconnect the lead wire and earth wire from terminal; Photo 5
  • Page 29 – Removing the drain pump; Photo 6; Photo 7; Removing the thermistor
  • Page 31 – Part number that is circled is not shown in the figure.
  • Page 33 – RoHS PARTS LIST; RoHS; Wiring
Loading the manual

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS

TECHNICAL & SERVICE MANUAL

No. OC341

REVISED EDITION-B

INDOOR UNIT

CONTENTS

1. TECHNICAL CHANGES ·······················2

2. FEATURES ···········································2

3. PART NAMES AND FUNCTIONS ········3

4. SPECIFICATION ···································5

5. OUTLINES AND DIMENSIONS············9

6. WIRING DIAGRAM ·····························10

7. REFRIGERANT SYSTEM DIAGRAM ···12

8. MICROPROCESSOR CONTROL·······13

9. TROUBLESHOOTING ························20

10. DISASSEMBLY PROCEDURE ···········27

11. PARTS LIST ········································30

12. RoHS PARTS LIST·····························33

July 2007

R410A / R22

NOTE:
• This manual describes only

service data of the indoor units.

• RoHS compliant products have

<G> mark on the spec name
plate.

• For servicing RoHS compliant

products, refer to the RoHS
PARTS LIST.

Revision:

• PMFY-P06/08/12/15NBMU-E

1

are

added in REVISED EDITION-B.

• Some descriptions have been

modified.

• Please void OC341 REVISED

EDITION-A.

PMFY-P06NBMU-E

PMFY-P06NBMU-E
PMFY-P06NBMU-E

1

PMFY-P08NBMU-E

PMFY-P08NBMU-E
PMFY-P08NBMU-E

1

PMFY-P12NBMU-E

PMFY-P12NBMU-E
PMFY-P12NBMU-E

1

PMFY-P15NBMU-E

PMFY-P15NBMU-E
PMFY-P15NBMU-E

1

Indoor unit
[Model names]

[Service Ref.]

OC341B--1.qxp 07.7.11 1:29 PM Page 1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FEATURES; Models; Indoor Unit; TECHNICAL CHANGES

2 2 FEATURES 1. Fresh Air Intake Air recycled indefinitely can become stale and stagnant with air quality suffering significantly. Fresh air is theanswer and it is for this reason that the PMFY- series takes in air directly from outdoors. This fresh air intakeallows you to enjoy the comfort of crisp...

Page 3 - PART NAMES AND FUNCTIONS; Guide vane; Returns air from room.; Filters; Wired remote controller

3 PART NAMES AND FUNCTIONS 3 Guide vane Air flow can be changed to horizontalby moving the guide vane to the left or right. Air intake Returns air from room. Filters Remove dust and pollutants from return air. Auto Air Swing Vane Disperses airflow up and down and adjusts the angle of airflow directi...

Page 4 - ̊F ̊C; Display Section

4 ● Wired remote controller ● ● ˚F˚C ˚F˚C ERROR CODE AFTER TIMER TIME SUN MON TUE WED THU FRI SAT ON OFF Hr AFTER FILTER FUNCTION ONLY1Hr. WEEKLY SIMPLE AUTO OFF Note: “PLEASE WAIT” messageThis message is displayed for approximately 3 minutes when power is supplied to the indoor unit or when the uni...

Other Mitsubishi Electric Models

All Mitsubishi Electric Other