Mitsubishi Electric PKA-A36KA4.TH - Manual

Mitsubishi Electric PKA-A36KA4.TH

Mitsubishi Electric PKA-A36KA4.TH – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – REFERENCE MANUAL; OUTDOOR UNIT SERVICE MANUAL; Radio frequency interface; RF thermostat
  • Page 3 – SAFETY PRECAUTION; Cautions for units utilising refrigerant R410A; Use new refrigerant pipes.; Never use any refrigerant other than that specified.
  • Page 4 – PART NAMES AND FUNCTIONS; Indoor unit; Be sure to use a filter drier for new refrigerant.; When charging directly from cylinder
  • Page 5 – Wired; °F°C; Display Section
  • Page 6 – IR wireless
  • Page 7 – SPECIFICATIONS; INDOOR UNIT
  • Page 8 – NOISE CRITERION CURVES; UNIT
  • Page 9 – OUTLINES AND DIMENSIONS
  • Page 10 – WIRING DIAGRAM
  • Page 11 – REFRIGERANT SYSTEM DIAGRAM; Heat exchanger
  • Page 12 – TROUBLESHOOTING
  • Page 13 – Malfunction-diagnosis method at maintenance service>; CHECK button; IR wireless remote controller
  • Page 20 – -4. TROUBLESHOOTING BY INFERIOR PHENOMENA
  • Page 21 – Note on the IR wireless remote control
  • Page 22 – (At the ambient temperature 50; Thermistor R
  • Page 23 – Wiring contact check; Sensor signal check
  • Page 24 – Indoor controller board; CNMF
  • Page 25 – -8. FUNCTIONS OF DIP SWITCH AND JUMPER WIRE
  • Page 26 – SPECIAL FUNCTION; again the former request code No.; Outline of functions; Main unit; System constraint; Operation pattern
  • Page 27 – • This function is available only in cooling mode.; NOTE; Rotation setting
  • Page 28 – (2) Setting method of each function by wired remote controller; TEST
  • Page 29 – DISASSEMBLY PROCEDURE; Water Cut; PHOTOS & ILLUSTRATIONS
  • Page 30 – Screw of electrical box; PHOTOS
  • Page 31 – (10) Lift the heat exchanger, and pull out the line flow fan to the; Screws of the motor bed
Loading the manual

SERVICE MANUAL

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SPLIT-TYPE, AIR CONDITIONERS

Note:

This manual describes only

service data of the indoor
units.

RoHS compliant products

have <G> mark on the spec
name plate.

CONTENTS

1. REFERENCE MANUAL................................... 2
2. SAFETY PRECAUTION................................... 3
3. PART NAMES AND FUNCTIONS................... 4
4. SPECIFICATIONS............................................ 7
5. NOISE CRITERION CURVES.......................... 8
6. OUTLINES AND DIMENSIONS....................... 9
7. WIRING DIAGRAM......................................... 10
8. REFRIGERANT SYSTEM DIAGRAM............ 11
9. TROUBLESHOOTING.................................... 12
10. SPECIAL FUNCTION..................................... 26
11. DISASSEMBLY PROCEDURE....................... 29

PARTS CATALOG (OCB488)

No. OCH488

REVISED EDITION-A

May 2011

ON/OFF

TEMP.

9 7 0 0 0 5 8

WIRED REMOTE

CONTROLLER

(Option)

INDOOR UNIT

Indoor unit

[Model names]

[Service Ref.]

PKA-A24KA4

PKA-A24KA4.TH

PKA-A30KA4

PKA-A30KA4.TH

PKA-A36KA4

PKA-A36KA4.TH

IR WIRELESS REMOTE

CONTROLLER

(Option)

ON/OFF

TEMP

Revision:

6. OUTLINES AND

DIMENSIONS has been modi-
fied in REVISED EDITION-A.

Some descriptions have been

modified.

Please void OCH488.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - REFERENCE MANUAL; OUTDOOR UNIT SERVICE MANUAL; Radio frequency interface; RF thermostat

2 1 REFERENCE MANUAL OUTDOOR UNIT SERVICE MANUAL Service Ref. Service Manual No. PUZ-A24/30/36NHA4PUZ-A24/30/36NHA4-BSPUY-A24/30/36NHA4PUY-A24/30/36NHA4-BS OCH481 OCB481 Radio frequency interface Wired remote controller IR wireless remote controller ON/OFF TEMP. COOL DRY AUTO FAN HEAT RF thermostat ...

Page 3 - SAFETY PRECAUTION; Cautions for units utilising refrigerant R410A; Use new refrigerant pipes.; Never use any refrigerant other than that specified.

3 SAFETY PRECAUTION 2 Cautions for units utilising refrigerant R410A 2-2. CAUTIONS RELATED TO NEW REFRIGERANT Use new refrigerant pipes. Store the piping to be used indoors during installation, and keep both ends of the piping sealed until just before brazing. (Leave elbow joints, etc. in their pack...

Page 4 - PART NAMES AND FUNCTIONS; Indoor unit; Be sure to use a filter drier for new refrigerant.; When charging directly from cylinder

4 Gravimeter Unit [3] Service tools Use the below service tools as exclusive tools for R410A refrigerant. 3 PART NAMES AND FUNCTIONS Indoor unit Emergency operation switch Front grille Air inlet Filter Air outlet Louver Vane No. Tool name Specifications 1 Gauge manifold · Only for R410A· Use the exi...

Other Mitsubishi Electric Models

All Mitsubishi Electric Other