Mitsubishi Electric PDFY-P15NMU-E - Manual
Mitsubishi Electric PDFY-P15NMU-E – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Before installation and electric work; Symbols used in the text; Carefully read the labels affixed to the main unit.; SAFETY PRECAUTIONS
- Page 3 – Precautions for devices that use
- Page 4 – Models; FEATURES; Indoor unit
- Page 5 – Operation buttons; PART NAMES AND FUNCTIONS; Air outlet
- Page 7 – SPECIFICATION
- Page 9 – OUTLINES AND DIMENSIONS
- Page 11 – WIRING DIAGRAM
- Page 13 – Gas pipe; Liquid pipe; Liquid pipe; REFRIGERANT SYSTEM DIAGRAM
- Page 14 – TROUBLE SHOOTING
- Page 15 – Thermistor R; Linear expansion valve; Operation summary of the linear expansion valve.
- Page 16 –
- Page 19 – DISASSEMBLY PROCEDURE; Be careful removing heavy parts.; Removing the control box cover; OPERATING PROCEDURE; Removing the thermistor
- Page 20 – Removing the thermistor and thermistor holder; Removing the drainpan
- Page 22 – Removing the filter
- Page 23 – Removing the drainpan with procedure 8-4
- Page 25 – 400 Lawrenceville Suwanee Road; Specifications are subject to change without notice.
TECHNICAL & SERVICE MANUAL
<Indoor unit>
PDFY-P06NMU-E,PDFY-P08NMU-E
PDFY-P12NMU-E,PDFY-P15NMU-E
PDFY-P18NMU-E,PDFY-P24NMU-E
PDFY-P27NMU-E,PDFY-P30NMU-E
PDFY-P36NMU-E,PDFY-P48NMU-E
2005
Models
Ceiling Concealed Built-in
Series PDFY
CONTENTS
SAFETY PRECAUTIONS ·························
1. FEATURES············································
2. PART NAMES AND FUNCTIONS ········
3. SPECIFICATION ···································
4. OUTLINES AND DIMENSIONS············
5. WIRING DIAGRAM ·····························
6. REFRIGERANT SYSTEM DIAGRAM····
7. TROUBLE SHOOTING························
8. DISASSEMBLY PROCEDURE ···········
For use with the R410A & R22
1
3
4
6
8
10
12
13
18
AIR CONDITIONERS CITY MULTI
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
1 - Inadequate connection and fastening may generate heat and cause a fire. • Prepare for typhoons and other strong winds and earthquakesand install the unit at the specified place. - Improper installation may cause the unit to topple and result in injury. • Always use an air cleaner, humidifier, el...
2 2. Precautions for devices that use Caution: • Do not use the existing refrigerant piping. - The old refrigerant and refrigerator oil in the existing piping con- tains a large amount of chlorine which may cause the refrigeratoroil of the new unit to deteriorate. • Use refrigerant piping made of C1...
3 PDFY-P06NMU-E PDFY-P08NMU-E PDFY-P12NMU-E PDFY-P15NMU-E PDFY-P18NMU-E PDFY-P24NMU-E PDFY-P27NMU-E PDFY-P30NMU-E PDFY-P36NMU-E PDFY-P48NMU-E 1.8 / 2.0 2.3 / 2.6 3.5 / 4.0 4.4 / 5.0 5.3 / 5.9 7.0 / 7.9 7.9 / 8.8 8.8 / 10.0 10.6 / 11.7 14.1 / 15.8 Ceiling Concealed Built-in Series PDFY Models Cooling...