Mitsubishi Electric PCA-A24GA - Manual

Mitsubishi Electric PCA-A24GA

Mitsubishi Electric PCA-A24GA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – • Indoor controller board has been changed.
  • Page 3 – Cautions for units utilising refrigerant R410A; Use new refrigerant pipes.; Be sure to use a filter drier for new refrigerant.; SAFETY PRECAUTION
  • Page 4 – Specifications
  • Page 5 – PART NAMES AND FUNCTIONS; Indoor Unit; Wired remote controller
  • Page 6 – ̊F ̊C; Display Section
  • Page 7 – Wireless remote controller
  • Page 8 – SPECIFICATIONS
  • Page 9 – NOISE CRITERION CURVES
  • Page 10 – OUTLINES AND DIMENSIONS; Ceiling; Allowing clearances
  • Page 12 – WIRING DIAGRAM
  • Page 13 – Heat exchanger; REFRIGERANT SYSTEM DIAGRAM
  • Page 14 – TROUBLESHOOTING
  • Page 19 – 0-3. TROUBLESHOOTING BY INFERIOR PHENOMENA
  • Page 21 – For emergency operation of cooling or heating
  • Page 23 – to; Thermistor R
  • Page 25 – Service board; 0-7. FUNCTIONS OF DIP SWITCH AND JUMPER WIRE
  • Page 26 – DISASSEMBLY PROCEDURE; Removing the air intake grille; (1) Slide the intake grille holding 2 knobs backward to open; OPERATING PROCEDURE; Removing the electrical box; remove the electrical cover.; Figure 1
  • Page 27 – Figure 3; Removing the side panel; side panel by sliding the panel to the front.; Removing the sirocco fan; upper side of the casing.; Photo 2
  • Page 28 – Removing the Under panel; Photo 4
  • Page 29 – Removing the drain pan; and left side drain pan.; Removing the guide vane; Photo 8
  • Page 30 – Removing the heat exchanger
  • Page 31 – Remarks
  • Page 32 – Part numbers that are circled are not shown in the figure.
  • Page 34 – RoHS PARTS LIST; Parts Name; RoHS
Loading the manual

SERVICE MANUAL

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SPLIT-TYPE, AIR CONDITIONERS

No. OC368

REVISED EDITION-B

INDOOR UNIT

REMOTE CONTROLLER

CONTENTS

1. TECHNICAL CHANGES ··································2

2. REFERENCE MANUAL ······································2

3. SAFETY PRECAUTION ···································3

4. PART NAMES AND FUNCTIONS ···················5

5. SPECIFICATIONS ············································8

6. NOISE CRITERION CURVES ··························9

7. OUTLINES AND DIMENSIONS ·····················10

8. WIRING DIAGRAM············································12

9. REFRIGERANT SYSTEM DIAGRAM ··················13

10. TROUBLESHOOTING ···································14

11. DISASSEMBLY PROCEDURE·······················26

12. PARTS LIST ···················································31

13. RoHS PARTS LIST ········································34

ON/OFF

TEMP.

Indoor unit

[Model names]

[Service Ref.]

PCA-A24GA

PCA-A24GA
PCA-A24GA

1

PCA-A30GA

PCA-A30GA
PCA-A30GA

1

PCA-A36GA

PCA-A36GA
PCA-A36GA

1

PCA-A42GA

PCA-A42GA
PCA-A42GA

1

Model name
indication

June 2007

NOTE:
• This manual describes only

service data of the indoor
units.

• RoHS compliant products have

<G> mark on the spec name
plate.

• For servicing RoHS compli-

ant products, refer to the RoHS
PARTS LIST.

Revision:
• WIRING DIAGRAM has been

changed in REVISED EDI-
TION-B.

• Some descriptions have been

modified.

• Please void OC368

REVISED

EDITION-A

.

3 3 2 2 3

OC368B--1.qxp 07.6.20 1:01 PM Page 1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - • Indoor controller board has been changed.

2 1 TECHNICAL CHANGES 2 REFERENCE MANUAL Service Ref. PUZ-A18/24/30/36/42NHAPUZ-A18/24/30/36/42NHA-BSPUY-A12/18/24/30/36/42NHA (1) PUY-A12/18/24/30/36/42NHA (1) -BS Service Manual No. OC367 2-1. OUTDOOR UNIT SERVICE MANUAL Series (Outdoor unit) PUZ-A·NHA PUZ-A·NHA-BSPUY-A·NHA PUY-A·NHA-BS Manual No....

Page 3 - Cautions for units utilising refrigerant R410A; Use new refrigerant pipes.; Be sure to use a filter drier for new refrigerant.; SAFETY PRECAUTION

3 Cautions for units utilising refrigerant R410A 3-2. CAUTIONS RELATED TO NEW REFRIGERANT Use new refrigerant pipes. Make sure that the inside and outside of refrige-rant piping is clean and it has no contaminationsuch as sulfur hazardous for use, oxides, dirt, shaving particles, etc.In addition, us...

Page 4 - Specifications

4 Gravimeter Unit [3] Service tools Use the below service tools as exclusive tools for R410A refrigerant. No. Specifications 1 Gauge manifold ·Only for R410A ·Use the existing fitting specifications. (UNF1/2) ·Use high-tension side pressure of 5.3MPa·G or over. 2 Charge hose ·Only for R410A ·Use pre...

Other Mitsubishi Electric Models