Mitsubishi Electric PAC-YG31CDA - Manual

Mitsubishi Electric PAC-YG31CDA

Mitsubishi Electric PAC-YG31CDA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
Page: / 46

Table of Contents:

  • Page 4 – Safety Precautions
  • Page 6 – System Requirements; Item Contents; Compatible Airconditioner; BACnet IF has functions: air conditioner controller.
  • Page 8 – System Configuration; System Configuration Example
  • Page 9 – Group Configuration
  • Page 10 – Functional specification; Communication Protocol Specification; APDU of BACnet; NPCI of BACnetNETWORK; )Application of BACnet
  • Page 12 – Object and Management Item; and 6 figures
  • Page 14 – Initiate :Issue of service; Execute: Reception and execution of service
  • Page 15 – Service list for every object; Service transceiver list for every object is shown below.; INIT; Note
  • Page 16 – Event Service specification
  • Page 17 – Setting functional list; The list of the setting functions of BACnet IF is arranged below.
  • Page 18 – Preparing for installation
  • Page 21 – This section describes how to uninstall “BACnet IF; ) Check to see if the BACnet IF has ended
  • Page 22 – Basic Mouse Operation; Part Names and Functions
  • Page 23 – Initial Startup and Shutdown; A test run of the air conditioning system has been completed.
  • Page 25 – System Setting Procedure; Perform the system setup, after Setting Tool starts.
  • Page 26 – Windows Elements; The initial setup screen of SetBACnet is shown below.
  • Page 27 – System Setting Procedure
  • Page 28 – Set the number and IP-Address of G-50A connected to the system.; Item Contents Set; It is communication port number.
  • Page 30 – Setup for BACnet
  • Page 31 – EVENT Notification; of COV
  • Page 33 – Notification Class Setting; Notification Class is set up for every Notification Class.; Notification Address Setting; Notification address is set up for every Notification Class.
  • Page 35 – The extended function of a system is set up.; Parameter Contents; Unit Of temperature; It checks, when using operation mode type “Dry”; Use Speed Type; It checks, when using the automatically reboot.
  • Page 37 – Step 1
  • Page 40 – Step 3
  • Page 41 – BACnet Interface PAC-YG31CDA Site; Adjustment; sheet
  • Page 43 – Appendix 1: Auto Log – In Confirmation Method
  • Page 44 – Appendix 2: Initial Value
Loading the manual



Mitsubishi Electric Air Conditioning Network System

BACnet

TM

Interface: PAC-YG31CDA (Ver. 1.30)

Operation Manual
















































Contents


1.Safety Precautions ………1

2.System Requirements ………2

3.System Configuration ………4

4.Functional specification ………6

5.Installation ………16

6.Part Name and Functions ………20

7.Initial Startup and Shutdown ………22

8.System

Setting

Procedure ………22

9.Site

Adjustment ………33

Appendix1: Auto Log – In Confirmation Method
Appendix2: Initial Value

Appendix3: Correcting the system setting data when

PC fails or is replaced.

Please read this manual before using the unit.

Please keep this manual for future use.

WT04221X03

2004-Mar. (Ver. 1.30)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 4 - Safety Precautions

1. Safety Precautions · Please read the Safety Precautions section very carefully before using the unit. · The safety cautions provided here are very important for your safety. Please observe them at all times. · The degrees of danger involved with incorrect operation of the unit are indicated in th...

Page 6 - System Requirements; Item Contents; Compatible Airconditioner; BACnet IF has functions: air conditioner controller.

2.System Requirements 2.1 Requirements (system recommendations) We recommend the following software and hardware when using this application (PAC-YG31CDA; BACnet IF). Item Contents Note PC PC/AT interchangeable machine CPU Pentium 4 1.8GHz or faster Memory 256 MB or more HDD 2GB or more 4GB or more ...

Page 8 - System Configuration; System Configuration Example

3.System Configuration 3.1 System Configuration Example Power supply unit G-50A G-50A [Image drawing] Indoor unit Outdoor unit LAN HUB BACnet IF Software Power supply unit Remote controller 3.2 Hardware Connection Diagram (1) LAN connection Connect the LAN cable to the PC. The location of the LAN co...

Other Mitsubishi Electric Models

All Mitsubishi Electric Other