Mitsubishi Electric OCH461 - Manual
Mitsubishi Electric OCH461 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – PART NAMES AND FUNCTIONS; Indoor unit
- Page 3 – °F°C; Display Section
- Page 4 – SPECIFICATION
- Page 6 – OUTLINES AND DIMENSIONS
- Page 7 – WIRING DIAGRAM; Legend
- Page 8 – REFRIGERANT SYSTEM DIAGRAM; Gas pipe; Models
- Page 9 – MICROPROCESSOR CONTROL; NOTE
- Page 12 – To be continued on the next page.; Type
- Page 13 – From the preceding page
- Page 14 – TROUBLESHOOTING
- Page 15 – Thermistor R; Operation summary of the linear expansion valve
- Page 16 –
- Page 17 – Fan operation at Heating mode; Models SW2
- Page 18 – Ju; Wireless remote controller pair number:; Effective; Rotar
- Page 21 – Figure 1; REMOVING THE FRONT PANEL; Photo 1; Front panel; Figure 3; Vane; Corner hole; PHOTOS & ILLUSTRATIONS; DISASSEMBLY PROCEDURE
- Page 22 – REMOVING THE INDOOR CONTROLLER BOARD AND; (3) Pull the nozzle assembly toward you as opening the catch; Photo 4
- Page 23 – REMOVING THE NOZZLE ASSEMBLY AND DRAIN HOSE; upper left side and remove the corner box.; Photo 5; REMOVING THE LINE FLOW FAN AND THE FAN MOTOR; Photo 6; REMOVING THE VANE MOTOR; Photo 8; THERMISTOR; Photo 9
- Page 24 – TM
TECHNICAL & SERVICE MANUAL
CONTENTS
1. PART NAMES AND FUNCTIONS .......... 2
2. SPECIFICATION ..................................... 4
3. OUTLINES AND DIMENSIONS .............. 6
4. WIRING DIAGRAM ................................. 7
5. REFRIGERANT SYSTEM DIAGRAM .......... 8
6. MICROPROCESSOR CONTROL ........... 9
7. TROUBLESHOOTING .......................... 14
8. DISASSEMBLY PROCEDURE ............. 21
Indoor unit
[Model names]
[Service Ref.]
PKFY-P06NBMU-E
PKFY-P06NBMU-E
PKFY-P08NBMU-E
PKFY-P08NBMU-E
No. OCH461
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
R22
R410A
Note:
•
This manual describes
only service data of the
indoor units.
•
RoHS compliant products
have <G> mark on the
spec name plate.
April 2009
PARTS CATALOG (OCB461)
INDOOR UNIT
Model name
indication
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 1 PART NAMES AND FUNCTIONS Indoor unit Wireless remote controller ON/OFF TEMP FAN VANE TEST RUN AUTO STOP AUTO START h min LOUVER MODE CHECK RESET SET CLOCK MODEL SELECT NOT AVAILABLE CHECK TEST RUN °C AMPM AMPM °F VANE CONTROL button Used to change the air flow CLOCK button RESET button SET butto...
33 Wired remote controller °F°C °F°C ERROR CODE AFTER TIMER TIME SUN MON TUE WED THU FRI SAT ONOFF HrAFTER FILTER FUNCTION ONLY1Hr. WEEKLY SIMPLE AUTO OFF PAR-21MAA ON/OFF FILTER CHECK OPERATION CLEAR TEST TEMP. MENU BACK DAY MONITOR/SET CLOCK ON/OFF ● ● Display Section For purposes of this explanat...
4 2.3 8,000 0.030.15 2.6 9,000 0.030.15 Note : Unit converter kcal/h = kW × 860Btu/h = kW × 3,412cfm = m 3 /min × 35.31 lb = kg/0.4536 *Above specification data is subject to rounding variation. Service Ref. Power sourceCooling capacity (Nominal) Heating capacity(Nominal ) External finishExternal di...