Table of Contents:
- Page 3 – MS MICROPROCESSOR CONTROL ··························································· 4; MSZ, MSY MICROPROCESSOR CONTROL ··············································· 7; Indoor unit models; MXZ MICROPROCESSOR CONTROL ······················································· 21; Outdoor unit models
- Page 4 – MS MICROPROCESSOR CONTROL; Indoor fan speed control; Coil frost prevention
- Page 7 – MSZ,MSY MICROPROCESSOR CONTROL
- Page 9 – Gradation of fan speed in initial
- Page 10 – Time chart of defrosting in HEAT mode (reverse type)
- Page 11 – MUZ
- Page 12 – Function of main parts
- Page 14 – Input voltage; At normal operation
- Page 17 – -8. OPERATIONAL FREQUENCY CONTROL OF OUTDOOR UNIT
- Page 19 – Operational frequency; LEV opening degree
- Page 21 – MXZ MICROPROCESSOR CONTROL
- Page 22 – Elimination of electrical noise
- Page 23 – NOTE
- Page 30 – -5. DISCHARGE TEMPERATURE PROTECTION CONTROL
- Page 31 – Compressor uses 50 W when pre-heat control is turned ON.; Coil frost prevention; ON
MS-A•WA
· MU-A•WA
MSZ-A•NA
· MUZ-A•NA
· MUZ-A•NA -
U
MSY-A•NA
· MUY-A•NA
MSZ-FD•NA
· MUZ-FD•NA
· MUZ-FD•NA -
U
MSZ-D•NA
· MUZ-D•NA
· MUZ-D•NA -
U
MSY-D•NA
· MUY-D•NA
· MXZ-A•NA
SERVICE TECHNICAL GUIDE
CONTENTS
1. MS MICROPROCESSOR CONTROL ·················· 4
2. MSZ, MSY MICROPROCESSOR CONTROL ······ 7
3. MXZ MICROPROCESSOR CONTROL ·············· 21
Wireless type Models
Inverter-controlled multi system type Models
No. OBT16
REVISED EDITION-B
Please void OBT16 REVISED EDITION-A.
Revision B:
•
MXZ-2A20NA-
1
,
MXZ-4A36NA, MSZ-FD,
MSZ-D and MSY-D have been added.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
1. MS MICROPROCESSOR CONTROL ··························································· 4 Indoor unit models Outdoor unit models MS-A09WA MU-A09WA MS-A12WA MU-A12WA 1-1. COOL OPERATION ··············································································· 4 1-2. DRY OPERATION ·············...
4 MS MICROPROCESSOR CONTROL 1 1-1. COOL ( ) OPERATION MS-A•WA MU-A•WA 2. Indoor fan speed control Indoor fan operates continuously at the set speed by FAN SPEED CONTROL button regardless of the thermostat’s OFF-ON.In AUTO the fan speed is as follows. 1. Thermostat control Thermostat is ON or OFF by ...
7 MSZ,MSY MICROPROCESSOR CONTROL 2 2-1. COOL ( ) OPERATION 2. Indoor fan speed control Indoor fan operates continuously at the set speed by FAN SPEED CONTROL button regardless of the thermostat’s OFF-ON.In AUTO the fan speed is as follows. 1. Thermostat control Thermostat is ON or OFF by difference ...