Mitsubishi Electric GT15-75ABUSL - Manual

Mitsubishi Electric GT15-75ABUSL

Mitsubishi Electric GT15-75ABUSL – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

User's Manual

GT15-75QBUSL
GT15-75QBUS2L
GT15-75ABUSL
GT15-75ABUS2L

Thank you for purchasing the GOT1000 Series.

GT15 BUS CONNECTION UNIT

Prior to use, please read both this manual and detailed
manual thoroughly to fully understand the product.

MODEL

GT15-75BUSL-U

MODEL

CODE

1D7M04

IB(NA)-0800298-J(1106)MEE

z

SAFETY PRECAUTIONS

z

(Always read these precautions before using this equipment.)

Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this prod-
uct.
In this manual, the safety precautions are ranked as "DANGER" and
"CAUTION".

Note that the

CAUTION level may lead to a serious accident

according to the circumstances.
Always follow the precautions of both levels because they are impor-
tant to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.

Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.

Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.

DANGER

CAUTION

[DESIGN PRECAUTIONS]

[INSTALLATION PRECAUTIONS]

[WIRING PRECAUTIONS]

[STARTUP AND MAINTENANCE PRECAUTIONS]

[DISPOSAL PRECAUTIONS]

z

Do not bunch the control wires or communication cables with
the main circuit or power wires, or lay them close to each other.
As a guide, separate the lines by a distance of at least 100mm
(3.94 inches) otherwise malfunctions may occur due to noise.

z

Before mounting or dismounting this unit to or from the GOT,
always shut off GOT power externally in all phases.
Not doing so can cause a unit failure or malfunction.

z

Use this unit in the environment that satisfies the general
specifications described in the User's Manual for the GOT used.
Not doing so can cause an electric shock, fire, malfunction or
product damage or deterioration.

z

When installing this unit to the GOT, fit it to the connection
interface of the GOT and tighten the mounting screws in the
specified torque range.
Undertightening can cause a drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to
screw or unit damage.

z

Before connecting the Bus connection cable to this unit, always
shut off GOT power and PLC CPU power externally in all
phases.
Not doing so can cause a malfunction.

z

Insert and fit the bus connection cable into the connector of the
unit to be connected until it "clicks".
After fitting, check for lift which can cause a malfunction due to a
connection fault.

z

Before starting cleaning, always shut off GOT power externally
in all phases. Not doing so can cause a unit failure or
malfunction.

z

Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.

z

Do not touch the conductive areas and electronic parts of this
unit directly.
Doing so can cause a unit malfunction or failure.

z

Always secure the cables connected to the unit, e.g. run them in
conduits or clamp them.Not doing so can cause unit or cable
damage due to dangling, moved or accidentally pulled cables or
can cause a malfunction due to a cable contact fault.

z

Do not hold the cable part when unplugging any cable
connected to the unit. Doing so can cause unit or cable damage
or a malfunction due to a cable contact fault.

z

Always make sure to touch the grounded metal to discharge the
electricity charged in the body, etc., before touching the unit.
Failure to do so may cause a failure or malfunctions of the unit.

z

Dispose of this product as industrial waste.

CAUTION

DANGER

CAUTION

DANGER

CAUTION

DANGER

CAUTION

CAUTION

[TRANSPORTATION PRECAUTIONS]

Manuals

The following shows manuals relevant to this product.

For relevant manuals, refer to the PDF manuals stored in the CD-
ROM for the drawing software used.

© 2004 MITSUBISHI ELECTRIC CORPORATION

Compliance with the EMC and Low Voltage
Directives

To configure a system meeting the requirements of the EMC and Low
Voltage Directives when incorporating the Mitsubishi GOT (EMC and
Low Voltage Directives compliant) into other machinery or
equipment, refer to "EMC AND LOW VOLTAGE DIRECTIVES" of the
General Description included with the GOT used.
The CE mark, indicating compliance with the EMC and Low Voltage
Directives, is printed on the rating plate of the GOT.

Compliance with the Radio Waves Act (South
Korea)

This product complies with the Radio Waves Act (South Korea).
Note the following when using the product in South Korea.

이 기기는 업무용 (A 급 ) 전자파적합기기로서 판매자 또는 사용자
는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을
목적으 로 합니다 .

(The product is for business use (Class A) and meets the
electromagnetic compatibility requirements.
The seller and the user must note the above point, and use the
product in a place except for home.)

Packing List

The following items are included.

z

Make sure to transport the GOT main unit and/or relevant unit(s)
in the manner they will not be exposed to the impact exceeding
the impact resistance described in the general specifications of
the User's Manual for the GOT used, as they are precision
devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.

Detailed Manual

Manual name

Manual number

(Model code)

GT16 User's Manual (Hardware)

(Sold separately)

SH-080928ENG

(1D7MD3)

GT15 User's Manual

(Sold separately)

SH-080528ENG

(1D7M23)

GOT1000 Series Connection Manual
(Mitsubishi Products) for GT Works3

(Sold separately)

SH-080868ENG

(1D7MC2)

Relevant Manuals

Model

Product

Quantity

GT15-75QBUSL,
GT15-75QBUS2L,
GT15-75ABUSL,
GT15-75ABUS2L

Bus connection unit

1

Stickers

12

CAUTION

1. OVERVIEW

This User's Manual describes the GT15 bus connection unit
(hereinafter referred to as the bus connection unit).
Use the bus connection unit for making bus connection of the GOT.
Refer to the User's Manual for the GOT used for the applicable GOT.

2. SPECIFICATIONS

The performance specifications of the bus connection unit are
indicated below.
The general specifications of the bus connection unit are the same
as those of the GOT.
Refer to the User's Manual for the GOT used for the general
specifications of the GOT.

* When the GOT power is on, the internal current consumption is

included in the current consumption of the GOT.
When the GOT power is off, the internal current is supplied from
the power supply of the PLC system.

Select the used bus connection unit according to the connection
target and connection position.

<Bus connection unit selection example>

(1) Select the bus connection unit according to the connection target.

When using the bus connection, make the communication
settings to perform communication between the GOT and PLC.
Refer to GOT1000 Series Connection Manual for details of bus
connection.

Item

GT15-

75QBUSL

GT15-

75QBUS2L

GT15-

75ABUSL

GT15-

75ABUS2L

Interface

QCPU (Q Mode)

bus connection

QnA/ACPU

bus connection

Connector

IN

1

1

1

1

OUT

-

1

-

1

I/O occupied

points

16 points

(I/O assignment:16

intelligent points)

32 points

(I/O assignment:

Special 32 points)

Internal current

consumption

(5VDC)*

0.44A

0.44A

0.12A

0.12A

Weight

0.13kg

(0.29lb)

0.14kg

(0.31lb)

0.13kg

(0.29lb)

0.14kg

(0.31lb)

(2) Select the bus connection unit according

to the GOT connection position.

Placed midway
: GT15-75QBUS2L/GT15-75ABUS2L

Placed at end
: GT15-75QBUSL/GT15-75ABUSL
GT15-75QBUS2L/GT15-75ABUS2L

QCPU (Q Mode), motion controller Q series

: GT15-75

Q

BUSL/GT15-75

Q

BUS2L

ACPU, QnACPU, motion controller A series

: GT15-75

A

BUSL/GT15-75

A

BUS2L

3. PART NAMES AND EXTERNAL

DIMENSIONS

Unit: mm (inch)

Dimensions of X when the bus connection unit is mounted to the
GOT

Unit : mm(inch)

*1 When the GT15-75QBUSL/GT15-75ABUSL is used, only the IN

side connector is available.

Model

A

GT15- 75QBUSL

2.5(0.10)

GT15- 75QBUS2L

2.5(0.10)

GT15- 75ABUSL

4(0.16)

GT15- 75ABUS2L

4(0.16)

GOT

GT16

GT15

15”

6.5 (0.26)

8 (0.31)

12.1”

5(0.20)

5 (0.20)

10.4”

8(0.31)

8(0.31)

8.4”

10 (0.39)

10 (0.39)

5.7”

10 (0.39)

10 (0.39)

137(5.39)

102(4.02)

4)

4)

5)

*1

2)

1)

17.5 (0.69)

Back view

3)

X

GOT

A

4. INSTALLATION PROCEDURE

The installation procedure for the bus connection unit is explained
using the GT1575.

(1) Power off the GOT.

(2) Remove two extension unit covers of the GOT.

(3) Fit the bus connection unit in the GOT case.

No.

Name

Description

1)

Bus connector (IN side)

Connector for connecting the
bus connection cable (IN side)

2)

Bus connector (OUT
side)

Connector for connecting the
bus connection cable (OUT side)

3)

Extended connector

Extension connector mounted to
the GOT

4)

Mounting screw

Screw (M3 screw) for fixing the
unit to the GOT

5)

Rating plate

-

(4) Fasten the bus connection unit by tightening its mounting screws

(4 places) with tightening torgue 0.36 to 0.48 N•m.

(5) After tightening screws, attach the supplied stickers to avoid

receiving electrostatic.

Warranty

Mitsubishi will not be held liable for damage caused by factors found
not to be the cause of Mitsubishi; machine damage or lost profits
caused by faults in the Mitsubishi products; damage, secondary
damage, accident compensation caused by special factors
unpredictable by Mitsubishi; damages to products other than
Mitsubishi products; and to other duties.

For safe use

• This product has been manufactured as a general-purpose part for

general industries, and has not been designed or manufactured to
be incorporated in a device or system used in purposes related to
human life.

• Before using the product for special purposes such as nuclear

power, electric power, aerospace, medicine or passenger
movement vehicles, consult with Mitsubishi.

• This product has been manufactured under strict quality control.

However, when installing the product where major accidents or
losses could occur if the product fails, install appropriate backup or
failsafe functions in the system.

Country/Region Sales office/Tel

U.S.A

Mitsubishi Electric Automation Inc.

500 Corporate Woods Parkway Vernon Hills, IL 60061, U.S.A.

Tel : +1-847-478-2100

Brazil

MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.

Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar

Paraiso, Sao Paulo, SP Brazil

Tel : +55-11-5908-8331

Germany

Mitsubishi Electric Europe B.V. German Branch

Gothaer Strasse 8 D-40880 Ratingen, GERMANY

Tel : +49-2102-486-0

U.K

Mitsubishi Electric Europe B.V. UK Branch

Travellers Lane, Hatfield, Hertfordshire., AL10 8XB, U.K.

Tel : +44-1707-276100

Italy

Mitsubishi Electric Europe B.V. Italian Branch

Centro Dir. Colleoni, Pal. Perseo-Ingr.2

Via Paracelso 12, I-20041 Agrate Brianza., Milano, Italy

Tel : +39-039-60531

Spain

Mitsubishi Electric Europe B.V. Spanish Branch

Carretera de Rubi 76-80,

E-08190 Sant Cugat del Valles, Barcelona, Spain

Tel : +34-93-565-3131

France

Mitsubishi Electric Europe B.V. French Branch

25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France

Tel : +33-1-5568-5568

South Africa

Circuit Breaker Industries Ltd.

Private Bag 2016, ZA-1600 Isando, South Africa

Tel : +27-11-928-2000

Hong Kong

Mitsubishi Electric Automation (Hong Kong) Ltd.

10th Floor, Manulife Tower, 169 Electric

Road, North Point, Hong Kong

Tel : +852-2887-8870

China

Mitsubishi Electric Automation (China) Ltd.

4/F Zhi Fu Plazz, No.80 Xin Chang Road,

Shanghai 200003, China

Tel : +86-21-6120-0808

Taiwan

Setsuyo Enterprise Co., Ltd.

6F No.105 Wu-Kung 3rd.Rd, Wu-Ku Hsiang,

Taipei

Hsine,

Taiwan

Tel : +886-2-2299-2499

Korea

Mitsubishi Electric Automation Korea Co., Ltd.

1480-6, Gayang-dong, Gangseo-ku Seoul

157-200,

Korea

Tel : +82-2-3660-9552

Singapore

Mitsubishi Electric Asia Pte, Ltd.

307

Alexandra

Road

#05-01/02,

Mitsubishi Electric Building, Singapore 159943

Tel : +65-6470-2460

Thailand

Mitsubishi Electric Automation (Thailand) Co., Ltd.

Bang-Chan Industrial Estate No.111 Moo 4, Serithai Rd,

T.Kannayao,

A.Kannayao,

Bangkok

10230

Thailand

Tel : +66-2-517-1326

Indonesia

P.T. Autoteknindo Sumber Makmur

Muara Karang Selatan, Block A/Utara

No.1 Kav. No.11 Kawasan Industri Pergudangan

Jakarta - Utara 14440, P.O.Box 5045 Jakarta, 11050 Indonesia

Tel : +62-21-6630833

India

Messung Systems Pvt, Ltd.

Electronic Sadan NO:III Unit No15, M.I.D.C Bhosari,

Pune-411026,

India

Tel : +91-20-2712-3130

Australia

Mitsubishi Electric Australia Pty. Ltd.

348 Victoria Road, Rydalmere, N.S.W 2116, Australia

Tel : +61-2-9684-7777

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.

Specifications subject to change without notice.
Printed in Japan, June 2011.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Mitsubishi Electric Models

All Mitsubishi Electric Other