Page 2 - FX2NC Series Programmable Controllers; Foreword
FX2NC Series Programmable Controllers Foreword • This manual contains text, diagrams and explanations which will guide the reader in the correct installationand operation of the FX1S Series Programmable Controllers. It should be read and understood beforeattempting to install or use the unit. • Furt...
Page 3 - Hardware Manual; Series Programmable Controllers; Date
FX 1S Series Programmable Controllers Hardware Manual FX1S Series Programmable Controllers Manual number : JY992D83901 Manual revision : B Date : April 2000
Page 4 - FX1S Series Programmable Controllers; Guidelines for the Safety of the User and Protection of the FX; This manual provides information for the use of the FX
FX1S Series Programmable Controllers ii Guidelines for the Safety of the User and Protection of the FX 1S . This manual provides information for the use of the FX 1S . The manual has been written to be used by trained and competent personnel. The definition of such a person or persons is asfollows: ...
Page 5 - Note’s on the Symbology Used in this Manual; ) Indicates a point of fur ther interest or fur ther explanation.; Software Warnings; ) Indicates a point of interest or fur ther explanation.
FX1S Series Programmable Controllers iii Note’s on the Symbology Used in this Manual At various times through out this manual cer tain symbols will be used to highlight points ofinformation which are intended to ensure the users personal safety and protect the integrity ofequipment. Whenever any of ...
Page 7 - Table of Contents; FX
FX1S Series Programmable Controllers Table of Contents v Table of Contents Guideline .......................................................................................................................... ii 1. Introduction ............................................................................
Page 11 - FX1S Series Programmable Controller; Introduction 1
1 Introduction 2 Terminal Layouts 3 Installation Notes 4 Power Supply 5 Inputs 6 Outputs 7 Diagnostics FX1S Series Programmable Controller Introduction 1
Page 12 - X1S Ser
Intr oduction 1 F X1S Ser ies Progr a mmab le Con troller
Page 13 - Introduction; Series Programmable
FX1S Series Programmable Controller Introduction 1 1-1 1. Introduction This manual covers the hardware installation instructions for the FX 1S Series Programmable Logic Controller. Table 1.1 : Relay Output Units MODEL INPUT OUTPUT POWER SUPPLY DIMENSIONS mm (inches) MASS (WEIGHT) kg (lbs) QTY TYPE Q...
Page 14 - DIN Rail
FX1S Series Programmable Controller Introduction 1 1-2 Figure 1.1: FX1S Outline Drawing The distance between the ver tical centerlines is 8mm (0.31”) less than the width of the unitPlease see previous page for each model’s width measurement. DIN Rail
Page 15 - Model name; F X; Unit type
FX1S Series Programmable Controller Introduction 1 1-3 1.1 Model name Table 1.3 : Model Table F X 1 S - 1 4 M T- E S S / U L C) A)B) D) F) E) A) PLC type : FX 1S B) Total number of I / O channels C) Unit type M MPU - main unit D) Output type R Relay T Transistor E) Features Omit AC, Japanese specifi...
Page 16 - World Specification; Production year
FX1S Series Programmable Controller Introduction 1 1-4 1.2 World Specification 1.3 Serial Numbers Table 1.4 : World / Japanese Specifications Input Sink / Source World spec models : SINK / SOURCEJapanese models : ALWAYS SINK OutputsTransistor World spec models : ALWAYS SOURCEJapanese models : ALWAYS...
Page 17 - Configuration
FX1S Series Programmable Controller Introduction 1 1-5 1.4 Configuration Figure 1.2: Schematic system B FX 1N -5DM FX 1N -EEPROM-8L FX 1S -10MR-ES/UL FX 1S -14MR-ES/UL FX 1S -20MR-ES/UL FX 1S -30MR-ES/UL FX 1S -10MT-ESS/UL FX 1S -14MT-ESS/UL FX 1S -20MT-ESS/UL FX 1S -30MT-ESS/UL FX 1N -232-BD FX 1N ...
Page 18 - Unit accessories; Memory Port
FX1S Series Programmable Controller Introduction 1 1-6 1.4.1 Unit accessories Table 1.6 : Configuration Notes A FX 1S Controller Main Body B FX 1N Memory Cassette or Display Unit C FX 1N Expansion Boards D FX 0N Network Adaptors E Programming Cables F Programming Software G HMI Devices, F900 GOT and...
Page 19 - Rules for Expansion; EEProm Backup Data
FX1S Series Programmable Controller Introduction 1 1-7 1.4.2 Rules for Expansion The FX1S Series can: • Use one expansion unit or board per square B, C, and G concurrently. • The FX1S can supply 400mA at 24V DC. The FX1S cannot: - Be expanded by the use of Special Funcion Blocks. - Supply a 5V DC se...
Page 23 - Terminal layouts 2; Terminal layouts; The following selection of terminal layouts are taken from the FX; Relay Output Controllers
FX1S Series Programmable Controllers Terminal layouts 2 2-1 2. Terminal layouts The following selection of terminal layouts are taken from the FX 1S product range. Note: All layouts are diagrammatic only and are intended to aid the creation of wiring diagrams. 2.1 Relay Output Controllers Figure 2.1...
Page 24 - Transistor Output Controllers
FX1S Series Programmable Controllers Terminal layouts 2 2-2 2.2 Transistor Output Controllers Figure 2.2: Terminal Layouts, Transistor Output S/S X1 N X0 X4 FX 1S -10MT-ESS/UL X5 0V Y0 Y1 Y2 Y3 X3 X2 24+ +V0 +V1 +V3 +V2 L S/S X1 N X0 X4 X6 FX 1S -14MT-ESS/UL X5 X7 0V Y0 Y1 Y2 Y4 X3 X2 24+ +V0 +V1 Y3...
Page 27 - Installation Notes 3; Installation Notes; The installation of FX
FX1S Series Programmable Controllers Installation Notes 3 3-1 3. Installation Notes The installation of FX 1S products has been designed to be safe and easy. When the products associated with this manual are used as a system or individually, they must be installed in asuitable enclosure. The enclosu...
Page 28 - Product Outline; PLC
FX1S Series Programmable Controllers Installation Notes 3 3-2 3.1 Product Outline Figure 3.1: Features of the FX 1S PLC Table 3.1 : Feature Table 1 Direct Mounting Holes (4.5 mm Diameter) 7 DIN Rail Mounting Clip 2 Input Terminals (24V DC) 8 Top Cover 3 Output Terminals 9 Optional Equipment port (Me...
Page 30 - General Specifications
FX1S Series Programmable Controllers Installation Notes 3 3-4 3.3 General Specifications Table 3.3: General Specifications Item Description Operating Temperature 0 to 55 °C (32 to 131 °F) Storage Temperature -20 to 70 °C (-4 to 158 °F) Operating Humidity 35 to 85% Relative Humidity, No condensation ...
Page 31 - PLC Mounting Arrangements
FX1S Series Programmable Controllers Installation Notes 3 3-5 3.4 PLC Mounting Arrangements To prevent a rise in temperature, mount the units to walls. Never mount them to the floor orceiling of an enclosure. Caution • Units should mot be installed in areas subject to the following conditions: exces...
Page 32 - DIN Rail Mounting; Cables ter minating at a screw ter minal of an FX
FX1S Series Programmable Controllers Installation Notes 3 3-6 3.5 DIN Rail Mounting Units can be snap mounted to 35mm DIN rail (DIN EN 50022). To release pull the springloaded clips away from the rail and slide the unit off and up. 3.6 Termination of Screw Terminals Cables ter minating at a screw te...
Page 35 - Power Supply 4; Power Supply; Wiring Techniques; The wiring of FX; Wiring Cautions
FX1S Series Programmable Controllers Power Supply 4 4-1 4. Power Supply 4.1 Wiring Techniques The wiring of FX 1S products has been designed to be safe and easy. If during the installation of these product or associated products concern is felt, please contact a professional electricianwho is traine...
Page 36 - Power Supply Characteristics; Power supply
FX1S Series Programmable Controllers Power Supply 4 4-2 4.4 Power Supply Characteristics *1 Includes the input current (5 or 7mA per point). Table 4.1 : Power Requirements FX 1S -10M FX 1S -14M FX 1S -20M FX 1S -30M Power supply 100 ~ 240V AC +10%, -15%, 50-60Hz Max. allowable momentary power failur...
Page 38 - Use a cable at least 0.2mm
FX1S Series Programmable Controllers Power Supply 4 4-4 4.5 Earthing / Grounding Use a cable at least 0.2mm 2 (AWG24) to ground equipment. Ground resistance must be less than 100 Ω (class 3). Note that the ground cable must not be connected to the same ground as the power circuits. Grounding is reco...
Page 41 - Inputs 5; Inputs; 4V DC Input Specifications; Input Specifications
FX1S Series Programmable Controllers Inputs 5 5-1 5. Inputs 5.1 24V DC Input Specifications Table 5.1: FX 1S Input Specifications FX 1S Main Unit X0 Æ Æ Æ Æ X7 X10 Æ Æ Æ Æ X17 Input voltage 24V DC +/- 10% Input current 24V DC, 7mA 24V DC, 5mA Input switching current OFF Æ ON >4.5mA >3.5mA ON Æ...
Page 42 - Typical wiring
FX1S Series Programmable Controllers Inputs 5 5-2 5.1.1 Typical wiring Figure 5.1: Input Wiring 1 24V DC Service Supply 2 PNP Sensor 3 NPN Sensor 4 Input Device Contact 5 FX 1S Controller Main Body 24V 0V S/S X0 X1 X2 NPN FX 1S -**MT-ESS/UL ➊ ➌ ➍ ➎ FX 1S -Sink 24V 0V S/S X0 X1 X2 PNP FX 1S -**MT-ESS...
Page 43 - Input Circuit Connection
FX1S Series Programmable Controllers Inputs 5 5-3 5.1.2 Input Circuit Connection Figure 5.2: Input Circuit Diagrams (Source/Sink) 5.1.3 Diodes and Inputs Connected in Series Figure 5.3: Diode Connection Diagram Vdrop across the diode Max. 4VNo more than 2 LEDs should be connected in series. 24V X 24...
Page 44 - Resistors and Inputs Connected in Parallel; Parallel resistance Rp: FX; Rb
FX1S Series Programmable Controllers Inputs 5 5-4 5.1.4 Resistors and Inputs Connected in Parallel Parallel resistance Rp: FX 1S = 15k Ω . If resistance Rp is less than the stated value, then add the Rb value using the Equation 1 calculation. Alternatively; Current leakage: FX 1S = 1.5mA. If the cur...
Page 47 - Outputs 6; Outputs; Relay Output
FX1S Series Programmable Controllers Outputs 6 6-1 6. Outputs Table 6.1: Output Specifications Description Relay Output Transistor Output Switched voltages (resistive load) ≤ 240V AC, ≤ 30V DC 5-30V DC Rated current / N points (resistive load) 2A/1 point, 8A/COM 0.5A/1 point, 0.8A/COM Max. Inductive...
Page 48 - Relay Output Example
FX1S Series Programmable Controllers Outputs 6 6-2 6.1 Relay Output Example Figure 6.1: Typical Relay Wiring Diagram n n n n Do not use this terminal o o o o Fuse p p p p Surge absorbing Diode. q q q q E x t e r n a l M e c h a n i c a lInterlock r Emergency Stop s Noise suppressor 0.1 µ F c a p a c...
Page 49 - Reliability Tests; Description; Load capacity
FX1S Series Programmable Controllers Outputs 6 6-3 6.1.1 Reliability Tests The test results in Table 6.2 were gathered from a 1 sec ON/OFF test cycle. Please note thatthe over current induced by in-rush greatly reduces the relay contacts service life. The rated lifefor an inductive AC load such as a...
Page 50 - Transistor Output Examples; Figure 6.3: Transistor Output Wiring Diagram
FX1S Series Programmable Controllers Outputs 6 6-4 6.1.3 Transistor Output Examples Figure 6.3: Transistor Output Wiring Diagram Figure 6.4: Japanese Model Transistor Output n n n n Do not use this terminal o o o o Emergency Stop p p p p Fuse q q q q E x t e r n a l M e c h a n i c a lInterlock r Ou...
Page 51 - Applying safe loads
FX1S Series Programmable Controllers Outputs 6 6-5 6.2 Applying safe loads Ensure all loads are applied to the same side of each PLC output, see previous figures. Loads which should NEVER simultaneously operate (e.g. direction control of a motor), because of a safety critical situation, should not r...
Page 55 - Diagnostics 7; Diagnostics; Preliminary Checks; Check power supply, ground and I/O cables are wired correctly.
FX1S Series Programmable Controllers Diagnostics 7 7-1 7. Diagnostics 7.1 Preliminary Checks Check power supply, ground and I/O cables are wired correctly. Turn the power supply on. Check the power LED is lit. Down load a small test program into the PLC. Verify the program to ensure it has been writ...
Page 56 - LED OFF; Remedy; LED is lit
FX1S Series Programmable Controllers Diagnostics 7 7-2 7.1.1 ERROR LED ON (CPU ERROR) FaultERROR LED ON RemedyReset PLC. Power OFF,ON and trigger RUN in-put. Possible results LED OFF Has the memory cassette been installed or removed while the units has still been powered? LED is lit Remedy Possible ...
Page 57 - Common Errors; Corroded contact points at some point in an I/O line.; Maintenance; Check interior temperature of the panel.
FX1S Series Programmable Controllers Diagnostics 7 7-3 7.2 Common Errors - Corroded contact points at some point in an I/O line. - An I/O device has been used outside its specified operating range. - An input signal occurs in a shor ter time period that taken by one program scan. 7.3 Maintenance - C...
Page 58 - Operation and Error Flags
FX1S Series Programmable Controllers Diagnostics 7 7-4 7.4 Operation and Error Flags Parallel link error Parameter error Syntax error Program (circuit) error Program execution error Execution error latch M8063 (ref. D8063) M8064 (ref. D8064) M8065 (ref. D8065, D8069) M8066 (ref. D8066, D8069) M8067 ...
Page 59 - Error Registers; Watchdog timer
FX1S Series Programmable Controllers Diagnostics 7 7-5 7.5 Error Registers 02H=EEPROM protect switch OFF0AH=EEPROM protect switch ON10H=MPU memory D8000 (default 200msec) D8001 D8002 D8003 D8004 D8007 Watchdog timer PC version 22100 = FX 1S Version 1.00 22 = FX 1S , 100 = Version 1.00 Memory capacit...
Page 60 - Error code for PLC hardware error
FX1S Series Programmable Controllers Diagnostics 7 7-6 D8061 D8063 D8064 D8065 D8066 D8067 D8068 D8069 Error code for PLC hardware error Error code for parallel link fault Parameter error code Syntax error code Program (circuit) error code Program execution error code Latched stepnumber of execution...
Page 61 - Error Codes
FX1S Series Programmable Controllers Diagnostics 7 7-7 7.6 Error Codes D8061 Check cable connections No error 0000 RAM error 6101 Operation circuit error 6102 I/O bus error (M8069 = ON) 6103 D8062 Check the programmer / PCconnections No error 0000 Parity/overrun/framing error 6201 Character error 62...
Page 62 - Instruction List
FX1S Series Programmable Controllers Diagnostics 7 7-8 7.7 Instruction List 000 010 020 030 040 050 060 070 080 TRANSFERS, COMP PROGRAM FLOW +- ×÷ , LOGICS SHIFT DATA OPERATION 1 HIGH-SPEED HANDY INSTR. 1 FX I/O DEVICES FX SER DEVICES 0 CJ CMP ADD ZRST REF IST RS 1 CALL ZCP SUB DECO PRUN 2 SRET MOV ...
Page 65 - Device List; Device Type
FX1S Series Programmable Controllers Diagnostics 7 7-11 7.8 Device List Device Type Description Program capacity 2K steps by FX 1S internal EEPROM or2K steps by FX 1N -EEPROM-8L Input (X) relay X0 - X17 (16 pts) (X + Y) ≤ 30 pts Max. Output (Y) relay Y0 - Y15 (14 pts) Auxiliary relay (512 pnts + 256...
Page 68 - HARDWARE MANUAL
HEAD OFFICE: MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100-8310 TELEX: J24532 CABLE MELCO TOKYOHIMEJI WORKS: 840, CHIYODA CHO, HIMEJI, JAPAN JY992D83901B(MEE0004) Effective Apr. 2000Specification are subjectto change without notice. HARDWARE MANUAL FX 1S SERIES PROGRAMMABLE CONTROLLERS