Mitsubishi Electric FR-E740 - Manual

Mitsubishi Electric FR-E740

Mitsubishi Electric FR-E740 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
Page: / 59

Table of Contents:

  • Page 2 – This section is specifically about safety matters; The
  • Page 3 – General instruction
  • Page 4 – REMARKS
  • Page 5 – OUTLINE; Product checking and parts identification; Inverter model; Accessory; · Fan cover fixing screws (M3; Refer to page 47; Harmonic suppression guideline (when inverters are used in Japan); Capacity plate; Rating plate
  • Page 6 – Operation panel; Names and functions of the operation panel; The operation panel cannot be removed from the inverter.
  • Page 7 – Operation mode switchover
  • Page 8 – Changing the parameter setting value; Operation Display
  • Page 9 – Parameter clear/all parameter clear; POINT; Pr.CL Parameter clear, ALLC all parameter clear; Setting
  • Page 10 – INSTALLATION AND WIRING; NOTE
  • Page 11 – Peripheral devices
  • Page 12 – Installation of the inverter and instructions; Note; Note; Leave enough clearances and take cooling measures.
  • Page 13 – Wiring; Terminal connection diagram; Main circuit; Single-phase power input
  • Page 14 – Terminal specifications; Type
  • Page 15 – IM; IM
  • Page 16 – Single-phase 200V class
  • Page 18 – The line voltage drop can be calculated by the following formula:; function occurs, increase the stall level.; select without frequency search (
  • Page 19 – Wiring of control circuit; Terminal layout; ) Strip off the sheath of the wire of the control circuit to wire.
  • Page 20 – ) It is recommended to use the wires of 0.3mm; Micro signal contacts
  • Page 21 – Connection of a dedicated external brake resistor (MRS type,
  • Page 22 – PRECAUTIONS FOR USE OF THE INVERTER; Refer to page 13
  • Page 23 – failure; (16) Handling of inverter output side magnetic contactor; Use shield cables as signal cables.; (13) Provide electrical and mechanical interlocks for MC1 and
  • Page 24 – FAILSAFE OF THE SYSTEM WHICH USES THE INVERTER; Interlock Method
  • Page 25 – DRIVING THE MOTOR; Setting the frequency by the operation panel; Operation using the setting dial as the potentiometer; Change of frequency with ON/OFF switches connected to terminals; refer to Chapter 4 of the Instruction Manual (Applied); Operation
  • Page 26 – Use the operation panel (
  • Page 27 – Setting the frequency by analog input (voltage input)
  • Page 28 – Start and stop using terminals (External operation); Setting the frequency by the operation panel (; Perform frequency setting by a voltage input signal
  • Page 29 – Switch ON the RH, RM, or RL signal to give a frequency command.; Start; Deceleration; Stop
  • Page 31 – Operating at 60Hz or higher using the external potentiometer
  • Page 32 – Acquiring large starting torque and low speed torque; Pr. 72 PWM frequency selection
  • Page 33 – Selection method of Advanced magnetic flux vector control; Test run
  • Page 35 – ENERGY SAVING OPERATION FOR FANS AND PUMPS; ENERGY SAVING OPERATION FOR FANS AND; Set
  • Page 36 – PARAMETERS; Chapter 4; Simple mode parameters; Only simple mode parameter can be displayed using
  • Page 37 – Parameter list
  • Page 41 – TROUBLESHOOTING; When a fault occurs, the inverter trips and a fault signal is output.; Reset method of protective function; to reset the inverter.; SD
  • Page 42 – List of fault displays; Function Name
  • Page 45 – Check first when you have a trouble; Description
  • Page 46 – Inspection items; PRECAUTIONS FOR MAINTENANCE AND INSPECTION; Precautions for maintenance and inspection
  • Page 47 – Replacement of parts; Part Name; For parts replacement, consult the nearest Mitsubishi FA Center.
  • Page 48 – Rating; 0 SPECIFICATIONS; Three-phase 200V power supply
  • Page 49 – Single-phase 100V power supply; Common specifications
  • Page 50 – Outline dimension drawings; When used with the plug-in option
  • Page 51 – APPENDIX; The authorized representative in the EU; Note: First environment; Appendix 1 Instructions for compliance with the EU Directives
  • Page 53 – Electronic thermal relay function operation characteristic
  • Page 54 – General Precaution; Wiring protection; any applicable provincial codes.; Short circuit ratings; Appendix 2 Instructions for UL and cUL
  • Page 55 – MEMO
  • Page 57 – For Maximum Safety; can affect or endanger human life.; Print Date; First edition
  • Page 58 – International FA Center
Loading the manual

FR-E700

INSTRUCTION MANUAL (BASIC)

FR-E720-0.1K to 15K

FR-E740-0.4K to 15K

FR-E720S-0.1K to 2.2K

FR-E710W-0.1K to 0.75K

INVERTER

700

5

6

7

8

9

10

4

3

2

1

CONTENTS

OUTLINE ...................................................................................1
INSTALLATION AND WIRING ...................................................6
PRECAUTIONS FOR USE OF THE INVERTER.........................18
FAILSAFE OF THE SYSTEM WHICH USES THE INVERTER ...20
DRIVING THE MOTOR.............................................................21
ENERGY SAVING OPERATION FOR FANS AND PUMPS ........31
PARAMETERS .........................................................................32
TROUBLESHOOTING ..............................................................37
PRECAUTIONS FOR MAINTENANCE AND INSPECTION ........42
SPECIFICATIONS ....................................................................44

Thank you for choosing this Mitsubishi Inverter.
This Instruction Manual (Basic) provides handling information and precautions for use of the equipment.
Please forward this Instruction Manual (Basic) to the end user.

To obtain the Instruction Manual (Applied)

Contact where you purchased the inverter, your Mitsubishi sales
representative, or the nearest Mitsubishi FA Center for the following
manual:

y

Instruction Manual (Applied) [IB(NA)-0600277ENG]

This manual is required if you are going to utilize functions and
performance.
The PDF version of this manual is also available for download at
"MELFANS Web," the Mitsubishi Electric FA network service on the
world wide web (URL: http://www.MitsubishiElectric.co.jp/melfansweb).

1
2
3
4
5
6
7
8
9

10

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - This section is specifically about safety matters; The

A-1 This Instruction Manual (Basic) provides handling information and precautions for use of the equipment.Please forward this Instruction Manual (Basic) to the end user. 1. Electric Shock Prevention 2. Fire Prevention 3.Injury Prevention 4. Additional Instructions Also the following points must be ...

Page 3 - General instruction

A-2 (2) Wiring (3) Trial run (4) Usage (5) Emergency stop (6) Maintenance, inspection and parts replacement (7) Disposal z Do not install a power factor correction capacitor or surgesuppressor/capacitor type filter on the inverter outputside. These devices on the inverter output side may beoverheate...

Page 4 - REMARKS

A-3 <Abbreviation> y PU: Operation panel and parameter unit (FR-PU04, FR-PU07) y Inverter: Mitsubishi inverter FR-E700 series y FR-E700: Mitsubishi inverter FR-E700 series y Pr.: Parameter number (Number assigned to function) y PU operation: Operation using the PU (operation panel/FR-PU04/FR-P...

Other Mitsubishi Electric Models

All Mitsubishi Electric Other