Mitsubishi Electric FR-D720-0.1K to 15K - Manual

Mitsubishi Electric FR-D720-0.1K to 15K

Mitsubishi Electric FR-D720-0.1K to 15K – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – This section is specifically about safety matters; The
  • Page 3 – General instruction; REMARKS
  • Page 4 – OUTLINE; Product checking and parts identification; Inverter model; Harmonic suppression guideline (when inverters are used in Japan); Capacity plate; Rating plate; Accessory; · Fan cover fixing screws (M3; Refer to page 43
  • Page 5 – Operation panel; Names and functions of the operation panel; The operation panel cannot be removed from the inverter.
  • Page 6 – Operation mode switchover
  • Page 7 – Changing the parameter setting value; POINT; Pr.CL Parameter clear; Operation; Setting
  • Page 8 – INSTALLATION AND WIRING; NOTE; circuit to protect them from noise.; for details of peripheral devices.
  • Page 9 – Peripheral devices
  • Page 10 – Installation of the inverters and precautions; Install the inverter vertically.; Note; Leave enough clearances and take cooling measures.
  • Page 11 – Wiring; Terminal connection diagram; After wiring, wire offcuts must not be left in the inverter.; Main circuit; Single-phase power input
  • Page 12 – Terminal specifications; Type
  • Page 13 – To change the input specification for terminal 4, set
  • Page 14 – Single-phase 200V class; IM
  • Page 15 – decrease especially at the output of a low frequency.
  • Page 16 – Wiring of control circuit; Pr. 72 PWM frequency selection; function occurs, increase the stall level.; select without frequency search (
  • Page 17 – Wire stripping length
  • Page 18 – Wire removal; input terminals; Use; Name; Changing the terminal assignment using; Product
  • Page 19 – Safety stop function; The terminals related to the safety stop function are shown below.; (3) Safety stop function operation; . (Please contact your sales representative; Pr.190 RUN terminal function
  • Page 20 – Connection of a dedicated external brake resistor (MRS type,; Do not use the brake resistor with a lead wire extended.
  • Page 21 – PRECAUTIONS FOR USE OF THE INVERTER; for the recommended wire sizes.; (5) The total wiring length should be within the prescribed length.
  • Page 22 – failure; (16) Handling of inverter output side magnetic contactor; Use shield cables as signal cables.; (13) Provide electrical and mechanical interlocks for MC1 and
  • Page 23 – FAILSAFE OF THE SYSTEM WHICH USES THE INVERTER; Interlock Method
  • Page 24 – DRIVE THE MOTOR; Setting the frequency by the operation panel; From where is the frequency command given?; Operation using the setting dial as the potentiometer
  • Page 25 – Using the setting dial like a potentiometer to perform operation; Pr. 160 Extended function display selection; Operation mode change; Start; setting according to the application.
  • Page 26 – Use the operation panel (
  • Page 27 – AU signal
  • Page 28 – Start and stop using terminals (External operation); Setting the frequency by the operation panel (; Perform frequency setting by a voltage input signal
  • Page 29 – Switch ON the RH, RM, or RL signal to give a frequency command.; Deceleration; Stop
  • Page 31 – Operating at 60Hz or higher using the external potentiometer
  • Page 32 – ENERGY SAVING OPERATION FOR FANS AND PUMPS; ENERGY SAVING OPERATION FOR FANS AND; Set; General-purpose magnetic flux vector control.
  • Page 33 – PARAMETERS; Chapter 4; Simple mode parameters; Pr.160 Extended function display selection
  • Page 34 – Parameter list
  • Page 37 – TROUBLESHOOTING; When a fault occurs, the inverter trips and a fault signal is output.; Reset method of protective function; to reset the inverter.
  • Page 38 – List of fault displays; Function Name
  • Page 40 – Check first when you have a trouble; Description
  • Page 41 – Inspection items; PRECAUTIONS FOR MAINTENANCE AND INSPECTION; Precautions for maintenance and inspection
  • Page 42 – Replacement of parts; Part Name; For parts replacement, contact the nearest Mitsubishi FA Center.
  • Page 43 – Rating; 0 SPECIFICATIONS; Three-phase 200V power supply
  • Page 44 – Single-phase 100V power supply; Common specifications
  • Page 45 – Outline dimension drawings; Three-phase 200V class; Inverter Model
  • Page 46 – The authorized representative in the EU; Note: First environment; Appendix 1 Instructions for Compliance with the EU Directives
  • Page 47 – page 8; Running
  • Page 48 – Electronic thermal O/L relay; low speed operation. Use a motor with a built-in thermal protector.
  • Page 49 – General precaution; Wiring protection; Refer to page 45; Short circuit ratings; The cables used should be 75°C copper cables.; Motor overload protection; Appendix 2 Instructions for UL and cUL; Appendix 3 SERIAL number check; Rating plate example; Symbol Year Month Control number
  • Page 50 – For Maximum Safety; can affect or endanger human life.; Print Date
  • Page 51 – International FA Center
Loading the manual

FR-D700

INSTRUCTION MANUAL (BASIC)

FR-D720-0.1K to 15K

FR-D740-0.4K to 15K

FR-D720S-0.1K to 2.2K

FR-D710W-0.1K to 0.75K

INVERTER

700

4

5

6

7

8

9

3

2

1

10

CONTENTS

OUTLINE ...................................................................................1
INSTALLATION AND WIRING ...................................................5
PRECAUTIONS FOR USE OF THE INVERTER.........................18
FAILSAFE OF THE SYSTEM WHICH USES THE INVERTER ...20
DRIVE THE MOTOR.................................................................21
ENERGY SAVING OPERATION FOR FANS AND PUMPS ........29
PARAMETERS .........................................................................30
TROUBLESHOOTING ..............................................................34
PRECAUTIONS FOR MAINTENANCE AND INSPECTION ........38
SPECIFICATIONS ....................................................................40

Thank you for choosing this Mitsubishi Inverter.
This Instruction Manual (Basic) provides handling information and precautions for use of the equipment.
Please forward this Instruction Manual (Basic) to the end user.

To obtain the Instruction Manual (Applied) and the

Safety stop function instruction manual

Contact where you purchased the inverter, your Mitsubishi sales
representative, or the nearest Mitsubishi FA Center for the following
manuals:

y

Instruction Manual (Applied) [IB(NA)-0600366ENG]

y

Safety stop function instruction manual [BCN-A211508-000]

These manuals are required if you are going to utilize functions and
performance.
The PDF version of this manual is also available for download at
"MELFANS Web," the Mitsubishi Electric FA network service on the
world wide web (URL: http://www.MitsubishiElectric.co.jp/melfansweb)

1
2
3
4
5
6
7
8
9

10

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - This section is specifically about safety matters; The

A-1 This Instruction Manual (Basic) provides handling information and precautions for use of the equipment.Please forward this Instruction Manual (Basic) to the end user. 1. Electric Shock Prevention 2. Fire Prevention 3.Injury Prevention 4. Additional Instructions Also the following points must be ...

Page 3 - General instruction; REMARKS

A-2 (2) Wiring (3) Trial run (4) Usage (5) Emergency stop (6) Maintenance, inspection and parts replacement (7) Disposal z Do not install a power factor correction capacitor or surgesuppressor/capacitor type filter on the inverter output side.These devices on the inverter output side may beoverheate...

Page 4 - OUTLINE; Product checking and parts identification; Inverter model; Harmonic suppression guideline (when inverters are used in Japan); Capacity plate; Rating plate; Accessory; · Fan cover fixing screws (M3; Refer to page 43

1 1 OUTLINE 1.1 Product checking and parts identification Unpack the inverter and check the capacity plate on the front cover and the rating plate on the inverter side face to ensure thatthe product agrees with your order and the inverter is intact. z Inverter model REMARKS · For how to find the SER...

Other Mitsubishi Electric Models