Page 2 - Foreword
F940GOT-SWD-E/LWD-E Foreword • This manual contains text, diagrams and explanations which will guide the reader in thecorrect installation and operation of the communication facilities of FX series. • Before attempting to install or use the communication facilities of FX series this manualshould be ...
Page 3 - HARDWARE MANUAL; Date
F940GOT-SWD-E/LWD-E i F940GOT-SWD-E/LWD-E HARDWARE MANUAL Manual number : JY992D77901 Manual revision : D Date : February 2000
Page 5 - iii; Note’s on the symbology used in this manual; ) Indicates a point of further interest or further explanation.
F940GOT-SWD-E/LWD-E iii Note’s on the symbology used in this manual At various times through out this manual certain symbols will be used to highlight points of information whichare intended to ensure the users personal safety and protect the integrity of the equipment. Whenever any ofthe following ...
Page 6 - iv; Memo
Page 7 - CONTENTS
F940GOT-SWD-E/LWD-E v CONTENTS 1. INTRODUCTION ...................................................................................1-1 1.1 Outline of product ................................................................................................ 1-2 1.2 Product configuration....................
Page 8 - Note to User
F940GOT-SWD-E/LWD-E vi 5. Maintenance ..........................................................................................5-1 5.1 Outline of maintenance ........................................................................................ 5-1 5.2 Replacement of battery ........................
Page 9 - INTRODUCTION; Confirm various functions of each unit.
INTRODUCTION 1. 1-1 1. INTRODUCTION This section describes the product configuration and the system configuration of the graphicoperation terminal. Confirm various functions of each unit. F940GOT-SWD-E/LWD-E
Page 10 - Outline of product
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 1-2 1.1 Outline of product The graphic operation ter minal (which may be hereafterabbreviated as "GOT") is attached on the panel face of acontrol panel or an operation panel, and connected to aprogram connector in an FX or A Series programmablecontroller (...
Page 11 - User screens; ) Screen display function
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 1-3 User screens 1) Screen display function The screens created by the user can be displayed. The following functions can be assignedto each screen. And the screens to be displayed can be limited using the security function. a) Display function -Up to 500 screens ...
Page 13 - System screens; and FX
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 1-5 System screens 1) Monitor function a) List program (only in the FX Series) - Programs can be read, written and monitored in the form of instruction list program. b) Buffer memory (only in the FX 2N and FX 2NC Series) -The contents of buffer memories (BFMs) of ...
Page 16 - Product configuration; Metal fixtures used to attach the GOT to a control panel
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 1-8 1.2 Product configuration The GOT is equipped with accessories (1) to (3) below. Par ts (4) to (8) are offered as options. 1) F940GOT (main body) F940GOT-SWD-E: 5.7" STN type LCD (with eight colors) F940GOT-LWD-E: 5.7" STN type LCD (with black and whit...
Page 18 - Optional parts; SW
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 1-10 Optional parts 4) Software to create user screens (3.5" FD) FX-PCS-DU/WIN-E V2.10 or later (in accordance with the Windows95) SW o D5C-GOTRE-PACK (" o " indicates a numeric not less than 1.) (in accordance with the Windows95 and the WindowsNT) 5) ...
Page 20 - This is attached when the GOT is delivered.
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 1-12 8) Battery PM-20BL (spare par t) This is used to back up the alarm history data, the real-time clock, etc. This is attached when the GOT is delivered. 9) EPROM memory to store the user screen data FX-EPROM- 4M This is an optional EPROM memory (M27C4002-**F (4...
Page 22 - System configuration; The system configuration to use the GOT is described below.
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 1-14 1.3 System configuration The system configuration to use the GOT is described below. F940GOT-SWD-E/LWD-E Data transfer cable FX-232CAB-1 (when the RS-232C connector in the personalcomputer is 9-pin type) or Data transfer cable FX-232CAB-2 (when the RS-232Ccon...
Page 29 - Installation, Wiring and General Specifications 2.; Installation, Wiring and General Specifications; Installation of main body; Caution on installation
Installation, Wiring and General Specifications 2. 2-1 2. Installation, Wiring and General Specifications This section describes installation of the GOT and wiring of the power supply. 2.1 Installation of main body Caution on installation • Use the unit in the environment for the general specificati...
Page 30 - ) Machining the mounting panel face; mm
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-2 The GOT is to be embedded in a panel. Perform the installation procedure described below. 1) Machining the mounting panel face On the panel face, drill a mounting hole of the dimensions shown on the right. * Make sure that th...
Page 31 - The GOT can be fixed in four positions at corners.; Enlarged view
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-3 3) Fixing the GOT Hang the hook of each metal fixture (offered as accessory) to a mounting hook hole in the GOT. Tighten a mounting bolt (offered as accessory) securely in each position. The GOT can be fixed in four positions...
Page 32 - Wiring of power supply; Cautions on Wiring; or more for a ground terminal in the graphic operation terminal.
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-4 2.2 Wiring of power supply Cautions on Wiring • Make sure to shut down the power supply outside the unit before star ting installation or wiring.If the power supply is not shut down outside, electrical shock or damages of the...
Page 33 - Connection examples
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-5 The power is supplied to the GOT from a PLC or an external power supply unit. • Connection examples 1) When the power is supplied from an FX Series PLC (Refer to "Cautions on connection" in the next page.) Connect the...
Page 34 - ) When the power is supplied from an external power supply unit
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-6 2) When the power is supplied from an external power supply unit Connect the power terminal provided on the rear face of the GOT to the 24V DC terminal in the external power supply unit. PLC GOT 24V 0V S/S RUN X0 X1 X2 - + DC...
Page 35 - Specifications of power supply unit
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-7 • Specifications of power supply unit Item Specifications F940GOT-LWD F940GOT-SWD Supply voltage 24V DC +10%-15% Power ripple 200mV or less Current consumption 390mA / 24V DC 410mA / 24V DC Allowable instantaneous power inter...
Page 36 - Cautions on connection; Series PLC, an external power supply unit is required.
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-8 Cautions on connection • The current consumption of the GOT is as shown in the table above. When supplying thepower to the GOT from the 24V DC service power in the FX Series PLC basic unit or exten-sion unit, take into accoun...
Page 37 - Functions of operation keys and connectors; Allows graphic display of 320
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-9 2.3 Functions of operation keys and connectors 1) Front panel a) Display unit Allows graphic display of 320 × 240 dots. Character string: 20 full-width characters × 15 lines 40 half-width characters × 15 lines Alphabets, nume...
Page 38 - Supplies the power to the GOT, and allows grounding.
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-10 2) Rear panel a) Power terminal Supplies the power to the GOT, and allows grounding. b) Battery PM-20BL Backs up the sampling data, the alarm history and the current time. The screen data is stored in the built-in flush memo...
Page 39 - ) Connectors provided on the side
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-11 3) Connectors provided on the side Used when a printer is connected or when a PLC is con-nected via a computer link unit. a) Connector for personal computer (RS-232C connector): D-sub 9-pin, male b) Connects a personal compu...
Page 40 - Outside dimensions; Panel cut dimensions: 153
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-12 2.4 Outside dimensions POWER RS23 2C RS42 2 152 (5.98) 162 (6.38) 120 (4.72) 130 (5.12) 57 (2.24) 5 (0.20) Outside painting color: Munsell 0.08GY 7.64/0.81 Mass: Approximately 1.0 kg including metal fixtures (0.1 kg) Panel c...
Page 41 - General specificationsl; Frequency Acceleration Amplitude
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-13 2.5 General specificationsl Ambient temperature During operation: 0 to +50 ° C (0 to +40 ° C when extension interface is used) During storage: -20 to +60 ° C Ambient humidity During operation: 35 to 85%RH (Condensation shall...
Page 42 - Effective display size: 115
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-14 Supply voltage 24V DC +10%, -15% Current consumption: 390 mA/24V DC (F940GOT-LWD-E) 410 mA/24V DC (F940GOT-SWD-E) Display element S T N t y p e f u l l - d o t m a t r i x L C D, m o n o c h r o m e ( F 9 4 0 G OT- LW D - E ...
Page 43 - Connection to personal computer; Use the following cable to connect a personal computer.
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-15 2.6 Connection to personal computer Use the following cable to connect a personal computer. a) F940GOT b) Personal computer c) FX-232CAB-1, FX-232CAB-2 or F2-232CAB-1 b) c) a)
Page 44 - Pin assignment and connection diagram of transfer cables
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-16 Pin assignment and connection diagram of transfer cables - Transfer cable FX-232CAB-1 - Transfer cable FX-232CAB-2 GOT side D-sub (female) 9-pin Personal computer side D-sub (female) 9-pin 54321 9876 54321 9876 2 3 6 8 5 4 2...
Page 46 - CPU port connection; Use either of the following cables to connect the PLC directly.
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-18 2.7 CPU port connection Use either of the following cables to connect the PLC directly. 1) When connecting the FX/FX 2C /A Series 2) When connecting the FX 0 /FX 0S /FX 0N /FX 2N /FX 2NC Series a) b) d) OU T I N OU T CP U¥E ...
Page 47 - Series PLC
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-19 a) F940GOT b) FX-40DU-CAB, FX-40DU-CAB-10M or FX-50DU-CABL c) FX-50DU-CAB0, FX-50DU-CAB0-1M, FX-50DU-CAB0-10M, FX-50DU-CAB0-20M, FX-50DU-CAB0-30M or FX-50DU-CAB0L d) FX/FX 2C Series PLC e) A Series PLC AnN, AnA, AnS, AnSJ, A...
Page 50 - Connection cable examples:
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-22 Connection cable examples: 1st GOT: FX-50DU-CAB0 (equivalent to connection cable for PLC) 2nd GOT: FX-232CAB-1 3rd GOT: Cable created by user (Refer to the connection diagram.) 4th GOT: FX-232CAB-1 Communication speed: The c...
Page 51 - In the case of the FX
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-23 • In the case of the FX 2N Series, communication can be performed by CPU por t connection (RS-232C communication) using the FX 2N -232-BD. In this case also, In the case of the FX 2N Series, communication can be performed by...
Page 53 - ; communication is star ted from the GOT unit nearest to the CPU.
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-25 <Cautions on connection of two or more GOT units> When two or more GOT units are connected to the FX/A/QnA Series PLC, communication isperfor med in the location sequence from the GOT unit nearest to the CPU (that is, ...
Page 54 - Computer link port connection (MELSEC A Series); Applicable PLC units and computer link units
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-26 2.8 Computer link port connection (MELSEC A Series) The GOT can be connected to the MELSEC A Series via a computer link unit as shown below. • Applicable PLC units and computer link units < A Series > AJ71UC24 A1SJ71UC...
Page 55 - Connect the GOT to the computer link unit (PLC) as shown below.
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-27 • Connect the GOT to the computer link unit (PLC) as shown below. < For RS-422 communication > < For RS-232C communication > The connection cable F2-232CAB is also available. D-sub (male) 9-pin Terminal block GOT...
Page 57 - Connection to SYSMAC C Series; Applicable PLC units and host link units
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-29 2.9 Connection to SYSMAC C Series The GOT can be connected to the SYSMAC C Series manufactured by OMRON via a host linkunit as shown below. • Applicable PLC units and host link units < SYSMAC C Series > A host link uni...
Page 60 - Connection to FLEX-PC N Series; Connection type
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-32 2.10 Connection to FLEX-PC N Series The GOT can be connected to the FLEX-PC N Series manufactured by FUJI Electric via a linkunit shown below. • Connection type • Applicable PLC units and link units < FLEX-PC N Series >...
Page 61 - Link unit
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-33 • Link unit - NB SeriesNB-RS1-AC, NB-RS1-DC - NJ SeriesNJ-RS2, NJ-RS4 - NS SeriesNS-RS1 - CPU in which RS-232C interface is built in NJ-CPU-B16 • Connection diagram Connect the GOT and the link unit (PLC) as shown below. <...
Page 63 - Connection by general-purpose communication; Outline
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-35 2.11 Connection by general-purpose communication The GOT can be connected to a general controller such as micro computer board.(The connected controller is hereafter referred to as "host (unit)".) • Outline In genera...
Page 66 - Communication setting; Baud rate
F940GOT-SWD-E/LWD-E Installation, Wiring and General Specifications 2. 2-38 • Communication setting The setting related to communication can be performed using the screen creation software or the GOT main body. To use general-purpose communication, - Screen creation software: Set the connected perso...
Page 67 - Startup
Startup 3. 3-1 3. Startup This section describes the star tup procedure from turning on of the power of the GOT to selec-tion of the mode. This section describes also the environment setting impor tant to use of the GOT. Make sure toread this section carefully. F940GOT-SWD-E/LWD-E
Page 68 - Startup procedure; •Perform wiring of the power supply unit of the GOT.
F940GOT-SWD-E/LWD-E Startup 3. 3-2 3.1 Startup procedure This paragraph describes the star tup procedure from turning on of the power of the GOT toselection of the mode. •Perform wiring of the power supply unit of the GOT. (Refer to Section 2.) •Connect the GOT and the PLC with an optional connectio...
Page 71 - Operation environment setting
F940GOT-SWD-E/LWD-E Startup 3. 3-5 3.2 Operation environment setting The operation environment setting function performs initial setting impor tant to operation of theGOT. The SET-UP MODE screen can be displayed by turning on the power while pressing andholding the upper left corner of the screen in...
Page 74 - • Set the language used on the system screens and the
F940GOT-SWD-E/LWD-E Startup 3. 3-8 Each setting screen is displayed as shown below. On each screen, when the END key at theupper right cor ner is pressed after setting is completed, the SET-UP MODE screen is dis-played. • Set the language used on the system screens and the user screens. a) SYSTEM LA...
Page 75 - Select the connected PLC type.
F940GOT-SWD-E/LWD-E Startup 3. 3-9 a) PLC TYPE A l l ow s t o s e l e ct e i t h e r o n e a mo n g F X S E R I E S, ASERIES, C SERIES (manufactured by OMRON), NSERIES (manufactured by FUJI Electr ic) and UNI-VERSAL (general-purpose communication). b) CONNECTION A l l o w s t o s e t t h e c o n n e...
Page 79 - •Set the menu call key which changes over the screen
F940GOT-SWD-E/LWD-E Startup 3. 3-13 •Set the menu call key which changes over the screen mo de (i n w hic h a u ser s cr ee n i s d isp laye d) t o th eSELECT MODE screen.The menu call key is mesh type, and 2 x 2 in size. • One or two corners can be selected among thefour corners of the screen. • Wh...
Page 83 - •The screen data stored in the GOT can be cleared.
F940GOT-SWD-E/LWD-E Startup 3. 3-17 •The screen data stored in the GOT can be cleared. •When "YES" is selected, the message "NOW CLEAR- ING USER DATA" is displayed and no key is accepted.When the message "COMPLETED!" is displayed, thedata is cleared completely. YES OK TO CLEA...
Page 85 - Extension Module; Data transfer adaptor
Extension Module 4. 4-1 4. Extension Module This section describes handling of the extension module interface provided on the rear face ofthe GOT. 4.1 Data transfer adaptor The data transfer adaptor F9GT-40UMB is used to store the user screen data stored in theEPROM for user screen data FX-EPROM-4M ...
Page 87 - )When transfer is finished, make sure to turn off the power of
F940GOT-SWD-E/LWD-E Extension Module 4. 4-3 5)When transfer is finished, make sure to turn off the power of the GOT and remove the adaptor b).
Page 89 - Maintenance; Outline of maintenance; Cautions on startup and maintenance
Maintenance 5. 5-1 5. Maintenance This section describes maintenance such as replacement of the battery and the backlight. 5.1 Outline of maintenance Cautions on startup and maintenance • Connect correctly the battery for memory backup. Never charge, disassemble, heat, put into fire nor short-circui...
Page 90 - When disposing of the unit, handle it as industrial waste.
F940GOT-SWD-E/LWD-E Maintenance 5. 5-2 CAUTION • Make sure to turn off the power before attaching or removing an extension module.If an extension module is attached/removed while the power is supplied, the contents stored in the memory or the EPROM memory itself may be damaged. • Never disassemble n...
Page 91 - Replacement of battery; When the head No. of the control devices is set to M0.
F940GOT-SWD-E/LWD-E Maintenance 5. 5-3 5.2 Replacement of battery When the battery voltage drops, the control devices for system information set by the screen cre-ation software becomes ON. The control devices are interlocking with auxiliary relays in the PLC.It is recommended to attach a lamp using...
Page 93 - Replacement of backlight
F940GOT-SWD-E/LWD-E Maintenance 5. 5-5 5.3 Replacement of backlight Replace the backlight F9GT-40LTS using the following procedure. Replacement procedure a)Mounting screw b)Backlight connector c)Backlight F9GT-40LTS d)Backlight fixing holder 1) Make sure that the power of the GOT is turned off. Remo...
Page 95 - Troubleshooting; This section describes troubleshooting during operation.; Power indication; When an abnormality has occurred, check the following points.
Troubleshooting 6. 6-1 6. Troubleshooting This section describes troubleshooting during operation. 6.1 Power indication When an abnormality has occurred, check the following points. The POWER LED in the GOT is lit by the 5 V power supply inside the GOT. When the POWERLED is extinguished, nothing is ...
Page 96 - Confirm the contents of an error, and take appropriate actions.; There are no screen data nor data files.
F940GOT-SWD-E/LWD-E Troubleshooting 6. 6-2 The table below shows the list of error messages displayed during manipulation and operationof the GOT. Confirm the contents of an error, and take appropriate actions. Error message Contents Actions CAN NOT WRITE TO PLC MEMORY. The PLC is running in the EPR...
Page 97 - The power supply of the PLC is set to OFF. Set to ON the power of the PLC.; SET NUMBER IS
F940GOT-SWD-E/LWD-E Troubleshooting 6. 6-3 Error message Contents Actions COMMUNICA- TION ERROR OCCURS.*1 The power supply of the PLC is set to OFF. Set to ON the power of the PLC. T h e c a bl e i s i m p e r fe c t l y c o n n e c t e d o rdefective. Connect the cable correctly.Or replace the cabl...
Page 98 - The created screen data is destroyed.
F940GOT-SWD-E/LWD-E Troubleshooting 6. 6-4 * When it is difficult to search the changed data, it is recommended to write the data again to the GOT from the screen data backup file created using the screen creation software. *1 When the cause of the communication error is removed, the error message a...
Page 99 - Applicable Versions and Models; Contents of Additional Functions; ) MELSEC QnA Series PC can be connected.; Model name
Additional Functions (in Ver3.00 or later) 7. 7-1 7. Additional Functions (in Ver3.00 or later) 7.1 Applicable Versions and Models Contents of Additional Functions 1) MELSEC QnA Series PC can be connected. CPU direct connection (RS-422) and computer link connection (RS-422, RS-232C) areavailable. 2)...
Page 100 - Connection to MELSEC QnA Series PC; Applicable PCs
F940GOT-SWD-E/LWD-E Additional Functions (in Ver3.00 or later) 7. 7-2 7.2 Connection to MELSEC QnA Series PC • Applicable PCs * Connection is same as that of the A Series except computer link connection via the RS- 422 interface whose connector is D-sub, 25-pin type.Refer to connection diagrams of t...
Page 101 - Connection to SLC 500 Series
F940GOT-SWD-E/LWD-E Additional Functions (in Ver3.00 or later) 7. 7-3 7.3 Connection to SLC 500 Series The SLC 500 Series PC manufactured by Allen-Bradley can be connected using a program-ming connector in the PC. • Applicable PCs<SLC 500 Series> <Connection status> SLC5/03, SLC5/04 CPU ...
Page 103 - Connection to Bar Code Reader; The F940-GOT can be connected to a bar code reader.; Communication port; Even
F940GOT-SWD-E/LWD-E Additional Functions (in Ver3.00 or later) 7. 7-5 7.4 Connection to Bar Code Reader The F940-GOT can be connected to a bar code reader. • Applicable bar code readersThe F940-GOT can be connected to any bar code reader whose communication specifica-tions and data format are as sho...
Page 105 - Screen Hard Copy Function
F940GOT-SWD-E/LWD-E Additional Functions (in Ver3.00 or later) 7. 7-7 7.5 Screen Hard Copy Function The screen being displayed can be output to a printer. • Applicable printersPrinter with ESC/P J84, RS-232C interface* Verified printer model name LBP450 (A4 laser printer) manufactured by CANON • Pri...
Page 106 - Key code; Deletes the entire alarm history.
F940GOT-SWD-E/LWD-E Additional Functions (in Ver3.00 or later) 7. 7-8 7.6 Additional Function in Alarm History Display • The following touch keys (key codes) are added in the alarm history display function. • The "delete" touch key having the same function as that of FFB6 is added also in th...
Page 107 - Additional Functions
Additional Functions (in V3.10 or later) 8. 8-1 8. Additional Functions (in V3.10 or later) 8.1 Applicable Versions and Models • VersionsF940GOT-SWD-E: Unit manufactured in October, 1999 or laterF940GOT-LWD-E (Whose manufacturer’s SERIAL No.9X**** or later) • SoftwareSW3D5C-GOTRE-PACK Version.A Dece...