Mitsubishi BACnet PAC-YG31CDA- User Manual

Mitsubishi BACnet PAC-YG31CDA

Mitsubishi BACnet PAC-YG31CDA– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
Page: / 82

Table of Contents:

  • Page 2 – DATA U4; Controllers; Group
  • Page 3 – Interface
  • Page 4 – Local remote controller; DATA U3; Functions; System example; LOCAL REMOTE CONTROLLER
  • Page 6 – Function to limit; Power supply; CENTRALIZED CONTROLLER AG-150A
  • Page 7 – External dimension
  • Page 8 – ting up a LOSSNAY and central controller system, connect a; ABS
  • Page 9 – Auto only supported for the CITY MULTI
  • Page 10 – LOSSNAY
  • Page 11 – System remote controller; CONTROLLER
  • Page 12 – System
  • Page 13 – Interlock operation with external system possible.
  • Page 14 – CENTRALIZED; remote
  • Page 15 – Installation plate; Auto mode is only for the CITY MULTI
  • Page 16 – MITSUBIS; Compatible
  • Page 17 – Field supplied power; CAUTION
  • Page 18 – manually turned back on.
  • Page 19 – The connection cable can be e; Peel off the label; ft
  • Page 20 – NOTE; NET transmission line.
  • Page 22 – Measurement status monitor (temperature
  • Page 23 – Mounting with L-shape metal
  • Page 24 – control
  • Page 25 – system consisting multiple Outdoor units.; Indoor/outdoor transmission line; control use needs following considerations.; Outdoor unit will cause GB-50A to shut down the whole system.
  • Page 27 – conditioners, the “Malfunction” signal will be shown.
  • Page 31 – Fan speed setting (including Auto) varies depending on the model.; Microsoft
  • Page 34 – Lead wire; connecting; Use
  • Page 35 – LAN connector of this device.; LAN
  • Page 36 – Malfunction List
  • Page 39 – Models with 2 air flow speed settings: Hi/Low; United States and other countries.
  • Page 40 – MA: MA remote controller
  • Page 41 – Centralized controller
  • Page 43 – following specifications.
  • Page 45 – Malfunction Log
  • Page 46 – Measurement status monitor (temperature
  • Page 47 – Table 3-8-1 Equivalent power consumption of controllers
  • Page 48 – -3 Connectable number of system controller when 1 G-50A is used.; -4 Connectable number of system controller when 1 GB-50A is used.; down on the whole system.
  • Page 49 – Cable fixture
  • Page 50 – Table 3-9-1 Equivalent power consumption of controllers
  • Page 51 – Total number of
  • Page 53 – The TG-2000A can realize the following functions
  • Page 54 – List of integral software functions; general equipment
  • Page 56 – Item; auxiliary heater may not be handled by these units.
  • Page 57 – Outdoor unit system; PC for central control; Necessary parts for the system
  • Page 58 – Lighting
  • Page 60 – If the quantity of G-50A exceeds 11 sets, one set of PLC is required; or; Demand
  • Page 62 – and M-NET Adapter LMAP03U
  • Page 63 – ACK Service is recommended for the network service.; Environment specification
  • Page 64 – External Dimensions; Usage Restrictions; monitor operating
  • Page 66 – centralized control line from the R410
  • Page 67 – • CPEV; * CPEV: PE insulated PVC jacketed shielded communication cable
  • Page 68 – • Operation input ON/OFF
  • Page 73 – CENTRALIZED CONTROLLER
  • Page 78 – OK
  • Page 79 – Lamp power source
  • Page 81 – Input
Loading the manual

CONTROLLER (Feb. 2009)

CNTR-1

CON
TROLLER

DATA U4

CITY MULTI

®

CONTROLLER

1. MITSUBISHI ELECTRIC’S AIR-CondITIonER nETwoRk SySTEM (MELAnS) .............................................CnTR-2

1-1. Function table of controllers ........................................................................................................................CnTR-3

2. LoCAL REMoTE ConTRoLLER .........................................................................................................................CnTR-4

2-1. deluxe MA remote controller [PAR-21MAA] ................................................................................................CnTR-4
2-2. ME remote controller [PAR-F27MEA-US] ...................................................................................................CnTR-5
2-3. Simple MA remote controller [PAC-yT51CRB] ............................................................................................CnTR-6
2-4. wireless remote controller [PAR-FL32MA / PAR-FA32MA] .........................................................................CnTR-7
2-5. LoSSnAy M-nET remote controller [PZ-52SF] ..........................................................................................CnTR-8

3. SySTEM ConTRoLLER ......................................................................................................................................CnTR-9

3-1. System group controller [PAC-SF44SRA] ...................................................................................................CnTR-9
3-2. Schedule timer [PAC-yT34STA] ................................................................................................................CnTR-11
3-3. on/oFF controller [PAC-yT40AnRA] .......................................................................................................CnTR-13
3-4. Central controller [G-50A] .........................................................................................................................CnTR-15
3-5. Central controller [GB-50A] .......................................................................................................................CnTR-23
3-6. Central controller [AG-150] ........................................................................................................................CnTR-31
3-7. Central controller [GB-24] .........................................................................................................................CnTR-39
3-8. Power supply unit [PAC-SC50kUA] ...........................................................................................................CnTR-47
3-9. Power supply unit [PAC-SC51kUA] ...........................................................................................................CnTR-50
3-10. Integrated centralized control software [TG-2000A] ..................................................................................CnTR-53
3-11. Electric amount count s

oftware [PAC-yG11

CdA] .....................................................................................CnTR-57

3-12. PLC software for general equipment [PAC-yG21CdA (Sw-PLC-GE)] .....................................................CnTR-58
3-13. BACnet

®

interface [PAC-yG31CdA (Sw-BACnet)] ...................................................................................CnTR-59

3-14. PLC software for demand input [PAC-yG41CdA] .....................................................................................CnTR-60
3-15.

L

on

W

orks

®

interface [LMAP03U] ..............................................................................................................CnTR-62

3-16. dIdo Controller [PAC-yG66dCA] .............................................................................................................CnTR-64

3-17. AI Controller [PAC-yG63MCA] ..................................................................................................................CnTR-69

3-18. Transmission booster [PAC-SF46EPA] ......................................................................................................CnTR-74

4. SySTEM CoMPonEnT .....................................................................................................................................CnTR-75

4-1. y-, R2-, S-Series .......................................................................................................................................CnTR-78
4-2. outdoor unit input/output connector (y-, R2-, S-Series) ............................................................................CnTR-79
4-3. Indoor unit “-E” type input/output connector (y-, R2-, S-Series) ................................................................CnTR-81

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - DATA U4; Controllers; Group

CNTR-2 CONTROLLER (Feb. 2009) CON TROLLER DATA U4 ™ I/O Controllers Group V 1 24 All of the local remote controllers feature liquid crystal LED displays and are easy to operate. This is a middle-scaled air conditioning management system, in which up to 2,000 indoor units can be centrally controlled ...

Page 3 - Interface

CONTROLLER (Feb. 2009) CNTR-3 CONTROLLER DATA U4 1-1. Function table of controllers LMAP03U: LonWorks ® Interface Controls up to 50 Groups/ 50 Indoor,Details refer to its description. PAC-YG31CDA: BACnet ® Interface Software Controls up to 500 Groups/ 500 Indoor, For details, see its description. (S...

Page 4 - Local remote controller; DATA U3; Functions; System example; LOCAL REMOTE CONTROLLER

CNTR-4 CONTROLLER (Feb. 2009) CON TROLLER DATA U4 2-1. Deluxe MA remote controller [PAR-21MAA] 2. Local remote controller DATA U3 Functions PAR-21MAA ON/OFF FILTER CHECK OPERATION CLEAR TEST TEMP. MENU BACK DAY MONITOR/SET CLOCK ON/OFF ERROR CODE AFTER TIMER TIME SUN MON TUE WED THU FRI SAT ONOFF Hr...

Other Mitsubishi Models