The TRANSITION Networks RS485-CF-0x series serial-port fiber extension Media
Converters extend distances between RS-485 or RS-482 nodes for
up to two (2)
kilometers over multimode fiber
or
up to twenty (20) kilometers over singlemode
fiber
.
RS485-CF-0x series Media Converters allow RS-485 two-wire half-duplex
o p e r a t i o n , R S - 4 8 5 f o u r - w i r e f u l l - d u p l e x o p e r a t i o n , a n d R S - 4 2 2 f o u r - w i r e
operation, with switch-selectable termination and biasing resistors, at speeds from
1 Kb/s to 500 Kb/s.
RS-485/422 Serial-Port Fiber Extension
Media Converters
RS485-CF-01, RS485-CF-02
USER’S GUIDE
RS485-CF-01
Provides one (1) terminal block RS-
4 8 5 / R S - 4 2 2 c o p p e r c o n n e c t o r a n d
one (1) set of RX (receive) and TX
(transmit)
ST
100BASE-FX connectors
to
multimode fiber @ 850 nM
.
RS485-CF-01(SM)
Provides one (1) terminal block RS-
4 8 5 / R S - 4 2 2 c o p p e r c o n n e c t o r a n d
one (1) set of RX (receive) and TX
(transmit)
ST
100BASE-FX connectors
to
singlemode fiber @ 1300 nM
.
RS485-CF-01(SC)
Provides one (1) terminal block RS-
4 8 5 / R S - 4 2 2 c o p p e r c o n n e c t o r a n d
one (1) set of RX (receive) and TX
(transmit)
SC
100BASE-FX connectors
to
multimode fiber @ 850 nM
.
RS485-CF-02
Provides one (1) DB-9 RS-485/RS-422
copper connector and one (1) set of
R X ( r e c e i v e ) a n d T X ( t r a n s m i t )
S T
100BASE-FX connectors to
multimode
fiber @ 850 nM.
RS485-CF-02(SM)
Provides one (1) DB-9 RS-485/RS-422
copper connector and one (1) set of
R X ( r e c e i v e ) a n d T X ( t r a n s m i t )
S T
100BASE-FX connectors to s
inglemode
fiber @ 1300 nM.
RS485-CF-02(SC)
Provides one (1) DB-9 RS-485/RS-422
copper connector and one (1) set of
R X ( r e c e i v e ) a n d T X ( t r a n s m i t )
S C
100BASE-FX connectors to
multimode
fiber @ 850 nM.
DB-9
Fi
b
er
RS485/422 to F
iber
Media Conv
erter
RS485-CF-0x in the Network . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . . . .4
Fault Isolation and Correction . . . . .5
Cable Specifications . . . . . . . . . . . . .6
Technical Specifications . . . . . . . . . .7
Compliance Information . . . . . . . . . .8
RS485-CF-0X in the NETWORK
The RS485-CF-0x can be used to install a fiber network extension between
RS-485 or RS-422 network nodes.
One slide switch on the RS485-CF-0x series Media Converter allows site
selection of RS-485 2-wire (half-duplex) operation, RS-485 4-wire (full-
duplex) operation, or RS-422 4-wire (full-duplex) operation (see page 3).
A second slide switch on the RS485-CF-0x series Media Converter allows
echo prevention in two-wire mode or transmission only on "transmit/receive -
(B) RS-485 2wire, transmit - RS-422 and transmit/receive + (A) RS-485 2wire,
transmit + RS-422" pair (see page 3).
A 4-position dip switch on the RS485-CF-0x series Media Converter allows
site selection of 130 ohm terminator insertion on the "receive – RS485 4
w i r e , R S 4 2 2 a n d r e c e i v e + R S 4 8 5 4 w i r e , R S 4 2 2 " p a i r o r o n t h e
"transmit/receive - (B) RS485 2wire, transmit - RS422 and transmit/receive +
(A) RS485 2wire, transmit + RS422" pair (see page 3.).
T h e d i p s w i t c h a l s o a l l o w s s i t e s e l e c t i o n o f 1 K o h m p u l l d o w n o n
"transmit/receive - (B) RS485 2wire, transmit - RS422" or of 1K ohm pull up
on "transmit/receive + (A) RS485 2wire, transmit + RS422” (see page 3).
RS485-CF-0x
2
RS-485/422 CABLE
RS-485/422 CABLE
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
INSTALLATION Set Switches Use small flatblade screwdriver or similar device to set recessed switchesaccording to site installation. 1. Set the 2-wire /4-wire slide switch to the 4-wire setting to enable the"receive – RS485 4 wire, RS422 and receive + RS485 4 wire, RS422"pair for RS422 4 wire...
FAULT ISOLATION and CORRECTION If the Media Converter fails, isolate and correct the failure by determining theanswers to the following questions and then taking the indicated action: 1. Is the P(o)w(e)r LED on the Media Converter illuminated?NO • Is the power adapter the proper voltage and cycle fr...
TECHNICAL SPECIFICATIONS Standards ANSI/TIA/EIA-485-A, IEEE 802.3™ Data Rate 1000 baud to 500,000 baud. (No rate setting is required. The Media Converteradjusts automatically to the baud rate.) Case Dimensions 4.7" x 3.0" x 1.8" (119mm x 76mm x 46mm) Shipping Weight 3 pounds (1.4 kilogra...