Page 2 - Sweden; as good as the exterior and that the ethics and morals that go into
We reserve the right to make changes without prior notice. Manufacturer: NIMO-VERKEN AB Box 288 542 23 Mariestad Sweden [email protected] www.nimoverken.com Dear NIMO customer,Congratulations on your excellent product selection and welcome to the NIMO family, a global family with roots in Sweden.We ...
Page 4 - ENGLISH; Safety; sioning of the drying cabinet read become.
4 ENGLISH 1 Safety These notes on safe operation have been compiled,to operate incorrectly and unnecessary accident risksand should be avoided before installation and commis- sioning of the drying cabinet read become. DO NOT MODIFY THIS PRODUCT.The drying cabinet must be installed and be kept indoor...
Page 5 - Applies to installation in countries outside the EU; Caution
ENGLISH 5 Applies to installation in countries outside the EU The device is not intended for use by persons (in- cluding children) with various disabilities or insuffi- cient experience and knowledge. They may only use the device under supervision or if they have received instructions on the use of ...
Page 6 - Specifications
6 ENGLISH A H E B I D C F G N P O M 1 2 3 4 J 2 Specifications 1 Control panel 2 Electrical connection for external fans 3 Electrical connection to the power grid 4 Exhaust air connection ø125 mm. Permanently connected to separate duct or general ventilation. A B C D E F G H I J M N O P mm 1200 750 ...
Page 7 - Installation; A full delivery must include:
B E F G C D A x2 x2 x4 x4 x2 x4 ENGLISH 7 3 Installation Position the drying cabinet where you want it to be placed.The carrying straps around the adjustable feeder can be used to lift the drying cabinet.Adjust the drying cabinet by the adjustable feet. Make sure that the top edges of the doors are ...
Page 8 - Mechanical installation
8 ENGLISH The wall brackets are attached to the top of the drying cabinet on delivery. Remove the wall brackets, rotate them and mount them as shown. (Screws and plastic plugs are included.) The drying cabinet must be fixed in the wall so that it cannot tip over. 3.2 Mechanical installation
Page 10 - Evacuation system
10 ENGLISH A m² 5 A m² 4 Evacuation system 4.1 Fresh air The drying cabinet must be connected directly to the ventilation duct (not via intermediate pipes or hoses). The drying cabinet has an exhaust air volume flow of up to 250 cubic meters per hour. This air is first taken from the room where the ...
Page 11 - Adjustment of the exhaust air; Measure the airflow in the duct; Reduce runoff
ENGLISH 11 4.2 Adjustment of the exhaust air The drying cabinet works most effectively when the airflow is optimal, about 200 m3/h. On the top of the drying cabinet there is a flap that can be set to a value that corresponds to the pressure drop in the duct. The maximum permissible pressure drop is ...
Page 12 - Set the outlet flap at the top of the cabinet to 50 Pa.; Increase drain
12 ENGLISH • Adjust the outlet flap at the top of the cabinet to the calculated pressure drop. The table shows common components in a ventilation system. The information in the table is to be understood as a guideline. For more information, please contact the manufacturer of the current system. NOTE...
Page 13 - Electrical connection
1 2 3 ENGLISH 13 The electrical connection of the device must be carried out in accordance with the appli- cable electrical safety regulations. 1 Connection for external fans 2 Connection to the power grid 3 Bezel • Loosen the two screws ( Torx T20) under the front panel (3). Square holes in the fra...
Page 14 - HELLO; Language setting
14 ENGLISH HELLO 1 2 3 4 • Make sure that the main ON/OFF switch on the drying cabinet is turned off. The display is unlit. • Hold down the UP ARROW and DOWN ARROW BUTTONS and press the ON/OFF switch to the ‘ON’ position. The display lights up and on the top row shows ‘P105’ flashing, which is the p...
Page 15 - Audit; May only be carried out by authorized personnel.; Operational; Once all tests have been passed, the machine is ready for operation.
ENGLISH 15 7 Audit May only be carried out by authorized personnel. After complete installation of the machine and before its use, a functional test must be carried out. Before the machine can be used again after a repair, a functional check must always be carried out. • Select the desired program a...
Page 16 - Information on scrapping; Disposal of the disused device; PE; documents relating to the device must be destroyed.; Handling the packaging
16 ENGLISH 8 Information on scrapping 8.1 Disposal of the disused device Before scrapping the machine, carefully check its physical condition and whether there is a risk of parts of the construction starting to crumble or break.The disposal of the equipment parts depends on their specific properties...
Page 18 - Handling of packaging GERMANY; Updated information on the disposal of waste equipment; Separate collection of WASTE equipment
18 ENGLISH 8.3 Handling of packaging GERMANY Updated information on the disposal of waste equipment The Electrical and Electronic Equipment Act (Elektra) contains many requirements for the handling of electrical and electronic equipment. The most important ones are compiled here. 1. Separate collect...