Maytag 8101P407-60- Manual

Maytag 8101P407-60

Maytag 8101P407-60– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
Page: / 33

Table of Contents:

  • Page 2 – Gemini Double Oven Range; Dimensions; Inches; REE
  • Page 3 – Mobile Homes
  • Page 4 – ANTI-TIP DEVICE INSTALLATION INSTRUCTIONS; STEP 3 - Range Installation
  • Page 5 – CONNECTING THE RANGE
  • Page 7 – RANGE ADJUSTMENTS; Top Section - Electric Ignition; Air Shutter - Oven and Broil Burner
  • Page 8 – GAS CONVERSION; General; MAXITROL REGULATOR
  • Page 9 – BAKE AND BROIL BURNERS TO LP/PROPANE GAS; To convert Bake Burner Orifice
  • Page 10 – For All Burner Locations:; SURFACE BURNERS TO LP/PROPANE GAS
  • Page 11 – SERVICE-PARTS INFORMATION
  • Page 12 – ADVERTENCIA ESPECIAL; MANUAL DE INSTALACIÓN; INSTALADOR; CONSERVE ESTE MANUAL PARA REFERENCIA FUTURA; Estufa individual de gas de; DIMENSIONES DEL HUECO; ENGLISH; ADVERTENCIA
  • Page 13 – Estufa Gemini con horno doble; Dimensiones; STUFAS INDIVIDUALES
  • Page 14 – Casas móviles
  • Page 15 – INSTRUCCIONES DE INSTALACIÓN DEL DISPOSITIVO ESTABILIZADOR; PASO 1 — Ubicación del soporte (vea la figura 1)
  • Page 16 – CONEXIÓN DE LA ESTUFA; Suministro eléctrico; Instrucciones de la conexión eléctrica a tierra; DESCONECTE EL SUMINISTRO ELÉCTRICO; Suministro de gas
  • Page 18 – AJUSTES DE LA ESTUFA; Sección superior — Encendido eléctrico
  • Page 19 – CONVERSIÓN DEL GAS; REGULADOR MAXITROL
  • Page 20 – QUEMADORES DE HORNEADO Y ASADO A GAS LP/PROPANO; Para convertir el orificio del quemador de asado:
  • Page 21 – En todas las ubicaciones de los quemadores:; QUEMADORES DE LA SUPERFICIE A GAS LP/PROPANO
  • Page 22 – CÓMO QUITAR LA ESTUFA PARA DARLE SERVICIO
  • Page 23 – AVERTISSEMENT SPÉCIAL; MANUEL DE MISE EN SERVICE; INSTALLATEUR; VEUILLEZ CONSERVER CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE; Cuisinière à gaz amovible; GAGEMENT DIMENSION
  • Page 24 – Cuisinière Gemini à deux fours; CUISINIÈRES AMOVIBLES
  • Page 26 – MISE EN PLACE DU SUPPORTDISPOSITIF DE STABILISATION; ÉTAPE 2 - Pose du support de stabilisation
  • Page 27 – RACCORDEMENT DE LA CUISINIÈRE; AVERTISSEMENT
  • Page 29 – RÉGLAGES DE LA CUISINIÈRE; Partie supérieure - Allumage électrique; Obturateur d’air - Brûleur du four et du gril
  • Page 30 – CONVERSION À UN GAZ DIFFÉRENT; Généralités; DÉTENDEUR MAXITROL
  • Page 31 – CONVERSION DES BRÛLEURS DE FOUR ET DE GRIL AU GPL/PROPANE; Pour convertir l’orifice du brûleur de four; Pour convertir l’orifice du brûleur du gril :
  • Page 32 – Pour tous les brûleurs:
  • Page 33 – DÉPLACEMENT DE LA CUISINIÈRE POUR LE DÉPANNAGE
Loading the manual

SPECIAL WARNING

INSTALLATION MANUAL

INSTALLER

: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE

PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE

THE MANUAL IS INTENDED TO ASSIST IN THE INITIAL INSTALLATION AND ADJUSTMENTS OF THE RANGE.

Only qualified personnel should
install or service this range.

Read “Safety Instructions” in the
Use & Care book before using
range.

Improper installation, adjustment,
alteration, service, maintenance or
use of range can result in serious
injury or property damage.

Your range may not be equipped with some of the features referred to in this manual.

·

ALL RANGES CAN TIP AND

CAUSE INJURIES TO

PERSONS.

·

INSTALL ANTI-TIP DEVICES

PACKED WITH RANGE.

·

FOLLOW ALL INSTALLATION

INSTRUCTIONS.

8101P407-60

(05-02-00)

CAUTION:

This range has been designed in

accordance with the requirements of various safety
agencies and complies with the maximum allowable
wood cabinet temperatures of 194

°

F. If this range is

installed with cabinets that have a lower working
temperature than 194

°

F, discoloration, delamination

or melting may occur.

Gas 30

²²²²

Wide Free-standing

Double Oven Range

Range may be installed with zero inches clearance
adjacent to (against) combustible construction at the rear
and on the sides below the cooktop. For complete
information in regard to the installation of wall cabinets
above the range and clearances to combustible wall
above the cook top see the installation drawings. For
SAFETY CONSIDERATIONS do not install a range in any
combustible cabinetry which is not in accord with the
installation drawings.

*

NOTE:

30 inch (76.2 cm) dimension between cook top

and wall cabinet shown on illustration does not apply to
ranges with an elevated oven or microwave. The 30 inch
(76.2 cm) dimension may be reduced to not less than 24
inches (61 cm) when the wall cabinets in a domestic
home are protected with fireproof materials in accordance
with American National Standards - National Fuel Gas
Code or in mobile homes when they are protected with
fireproof materials in accordance with the Federal
Standard for Mobile Home Construction and Safety.

To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet
storage is to be provided, the risk can be reduced by
installing a range hood that projects horizontally a
minimum of 5 inches (13 cm) beyond the bottom of the
cabinets.

CLEARANCE DIMENSIONS

ENGLISH

'

'

'

'

PP. 1-11

ESPAÑOL

'

'

'

'

pág. 12-22

FRANCAIS

'

'

'

'

p. 23-33

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Gemini Double Oven Range; Dimensions; Inches; REE

-2- Gemini Double Oven Range Dimensions Inches 25243036 9 9 1/4 4 1/2 1 1/2 Notes: 1. Provide for a 120 volt grounded electrical outlet in this area. Outlet MUST be flush. 2. Recommended gas line location. 3. Clearance for pressure regulator. 4. Excluding handle, dimension given is from wall to fron...

Page 3 - Mobile Homes

-3- DIMENSION “A” SIDE CLEARANCE ABOVE COOKING SURFACE = 3 INCHES (7.6 CM) (MINIMUM) ANY COMBUSTIBLE SURFACE 13 ² (33 CM) MAX. DEPTH OF CABINETS ABOVE COOKTOP 0 ² (0 CM) CLEARANCE BETWEEN ADJACENT COMBUSTIBLE AND THE BACK AND SIDES OF THE RANGE BELOW THE COOKING SURFACE. 36 ² (91.4 CM) 18 ² (45.7 CM...

Page 4 - ANTI-TIP DEVICE INSTALLATION INSTRUCTIONS; STEP 3 - Range Installation

-4- ANTI-TIP DEVICE INSTALLATION INSTRUCTIONS NOTE: A risk of range tip over exists if the appliance is not installed in accordance with the provided installationinstructions. The proper use of this device minimizes therisk of TIP-OVER. In using this device the consumer muststill observe the safety ...

Other Maytag Models