Mackie SP1200 - Manual
Mackie SP1200 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – CAUTION; AVIS; ATTENTION; Safety Instructions; Table of Contents; Tips on Installing and Using the SP1200—; WARNING; — To reduce the risk of fire or electric
- Page 3 – Key Features; Introduction
- Page 6 – Installation; Application Diagrams; A: Typical Monaural Application
- Page 7 – B: Multiple SP1200s—Multiple Zones—Shared Sources
- Page 8 – C: Expansion with Local Mic
- Page 9 – D: Room Combining—Zones; Zone A; Zone B
- Page 10 – Applications; A: Typical Mono Application; Tips on Installing and Using the
- Page 11 – Connections; Connecting the Program Sources
- Page 12 – Connecting the Remote Bus; REMOTE; Expansion Bus Connection Chart; Connecting the Expansion Bus; EXPANSION; Distance Chart for SP1200 Expansion Bus Cable
- Page 13 – Connecting the RS485 Serial Port; Internal Settings; Bus Assign; Note; must; Never; Bus Assign DIP Switch Location; Bus Assign Switch Chart
- Page 14 – EQ Bypass; Jumper J6, located on each Filter Board, allows; There are several jumpers on the Amplifier; Amplifier Configuration Internal Jumpers
- Page 15 – AC Power Considerations; Each SP1200 draws an average of 3 amps of AC; Voltage Conversion; The SP1200 can be configured to operate at; Thermal Considerations; leave at least one
- Page 16 – Operation; Program Inputs
- Page 19 – Using the Paging Mic; Setting the GAIN; Using the Ambient Mic
- Page 20 – Using the Local MIC/LINE INPUT; PHANTOM
- Page 21 – Using the EQ; Using the PRE OUT/AMP IN; Direct Speaker Connection; Using the Remote Connection; Connecting One or More Remote Controls; Using the RS485 Connection
- Page 22 – Using the SPLinker Sound Palette; Party Control System; Upgrading the Software
- Page 23 – Specifications
- Page 25 – Disclaimer; Mackie Industrial continually engages in research; Service Information; In the event that your SP1200 should require; Pack the unit in its original packaging. This is very; Mackie Industrial; Appendix A: Default Settings; Control
- Page 26 – Appendix B: Button Modes; AGC Reset
- Page 27 – Appendix C: Voltage Conversion; Make sure
SP1200 MUSIC CONTROLLER
INPUTS
OFF
3
0
3
6
9
15
30
55
1
2
3
4
ON
OL
STATUS
POWER
COMM PORT
ZONE A
MASTER
VOLUME
PHANTOM
PAGING
GAIN +40dB
MIC / LINE INPUT A
CAUTION:
TO REDUCE THE
RISK OF FIRE REPLACE WITH SAME
TYPE FUSE AND RATING
115V 60Hz FUSE 115/ T4A 120 WATTS
230V 50Hz FUSE 230/ T2A 120 WATTS
1 2 3 4
1 2 3 4 5 6 7 8
0
I
PROGRAM EQ
1 2 3 4
ZONE
A
GAIN +40dB
PHANTOM
ON
THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC
"MACKIE.","MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE. COPYRIGHT ©2000 ALL RIGHTS RESERVED
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC. • WOODINVILLE • WA • MADE IN USA • FABRIQUE AU USA
PAR ALLEL
INPUTS
G +
–
CONTROL
GROUND
ALL CALL
DIRECT
R
OUTPUT
PROGRAM INPUTS
1
2
3
4
PRIORITY
L
HIGH
U
+12
–12
U
+12
–12
LOW
GAIN
+
-
HIGH 12k
FREQ
MID
LOW 80Hz
U
+15
–15
U
+15
–15
U
+15
–15
1K
3K
400
8k
250
HIGH
U
+12
–12
U
+12
–12
LOW
GAIN
+
-
+
-
AMP IN
PRE OUT
PAGING MIC
EXPANSION IN
EXPANSION OUT
AMP ADDRESS
RS485
REMOTE
AMBIENT
MIC
MIC
VOX
RISK OF ELECTRIC SHOCK
DO NOT OPEN
REPLACE WITH THE SAME TYPE FUSE AND RATING.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE
UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE.
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER.
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
C A U T I O N
AVIS:
RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR
SERIAL NUMBER
MANUFACTURING DATE
ZONE A
OUTPUT SUITABLE
FOR CLASS 2 WIRING
100/ 70V/8
+
–
1
2
3
G
+
–
A
G
B
1 2 3 4 5 6 7 8
LOCAL
1
2
3
4
REMOTE
1
2
3
4
SP1200
MUSIC CONTROLLER
SP1200 Single-Channel
Program Controller/Amplifier
Instruction Manual
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
SP1200 – 2 CAUTION AVIS RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL ATTENTION: POUR EVITER LES RISQUES DE CHOC ELECTRIQUE...
SP1200 – 3 Audio expansion connectors are provided on the rear panel for connecting multiple SP1200s, withshared audio via balanced busing. Each of the fourprogram input signals are internally balanced andcan be independently assigned to the balanced buswith internal assignment switches. The LOCAL/ ...
SP1200 – 6 3. Installation Application Diagrams PHANTOM PAGING GAIN +40dB MIC / LINE INPUT A CAUTION: TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING 115V 60Hz FUSE 115/ T4A 120 WATTS 230V 50Hz FUSE 230/ T2A 120 WATTS 1 2 3 4 1 2 3 4 5 6 7 8 0 I PROGRAM EQ 1 2 3 4 ZONE A GAIN +40dB...