Lowrance EP-90R - Manual

Lowrance EP-90R

Lowrance EP-90R – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – The NMEA 2000 red female to blue female adapter cable allows users; Tools and Supplies; LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot
  • Page 3 – Installation; recommended; The hose-barb attachment
  • Page 5 – messages sent from a temperature sensor. A NMEA 2000 network; There are two types of LowranceNet red connectors: the single T; Network Backbone and Network Nodes; To pick up a phone and be able to hear a conversation from another
  • Page 6 – NMEA 2000 network node located at the end of a NMEA 2000 backbone.; Adding a Network Node
  • Page 7 – In this example, a new device is added to the NMEA 2000 bus by; Additional Network Information; came packed with this document.
  • Page 8 – Notes
  • Page 9 – Pressure Configuration; Boat Setup; To execute Boat Setup:
  • Page 10 – Boat Setup Reset; Hit menu to reset Eng/Tnk; EP-90R Pressure Configuration; Hit Menu to Cfg Pres Snsr
  • Page 11 – Hit Menu to Unset Dev; Displaying Pressure Sensor Data; Page Screen Rotation
  • Page 12 – Customizing Pages
  • Page 14 – Press Menu to Rst Values
  • Page 16 – Press ENTER to reset Eng/Tnk Cfg; Press Enter to Configure Pressure Snsr
  • Page 17 – Press Enter to add the selected page
  • Page 22 – Press Enter to Reset Values
  • Page 23 – The LMS-525cDF is one of many Lowrance display units that may be; Bus Setup
  • Page 24 – Engine & Tank Configuration; Bus Setup highlighted on the NMEA 2000 menu (left). Bus Setup
  • Page 25 – Engine/1Tank highlighted on Engine and Tank Configuration; Are you sure you wish to change the bus configuration?; EP-90R Pressure Sensor Configuration
  • Page 27 – Are you sure you wish to change this; Restore Defaults; Are you sure you wish to change this device's configuration?
  • Page 28 – Alarm Status Tab
  • Page 31 – LOWRANCE ELECTRONICS
  • Page 32 – How to Obtain Service...; ...outside Canada and the USA:; Accessory Ordering Information
Loading the manual

1

Pub. 988-0154-641

EP-90R Pressure

Electronic Sensor

Installation and Configuration Instructions

This document shows how to install an EP-90R Pressure sensor and

how to connect it to a NMEA 2000

®

network. It also provides

instructions on how to configure your pressure sensor with Lowrance

digital gauges (LMF-200 & LMF-400) and display units.
NMEA 2000 is the communication bus standard developed by the

National Marine Electronics Association (NMEA) for use in boats.

Lowrance has introduced a line of products that can communicate over

a NMEA 2000 network (LowranceNet).
All Lowrance NMEA 2000 capable devices are either NMEA 2000

certified or certification is pending.

CAUTION:

Installing LowranceNET NMEA 2000 devices is

significantly

different

from installing earlier Lowrance components without

NMEA 2000 features. You should read all of the installation
instructions before proceeding. Decide where you want to install
all components before drilling any holes in your vessel.

Some sonar or GPS display units may require a software upgrade to

display NMEA 2000 data correctly. For free software upgrades or

additional information on the LowranceNet NMEA 2000

®

network

system, visit our web site, www.lowrance.com.

EP-90R Pressure Sensor.

Hose barb

attachment

Red NMEA 2000

connector

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - The NMEA 2000 red female to blue female adapter cable allows users; Tools and Supplies; LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot

2 The EP-90R consists of a red cable connector and the EP-90R housing with standard size hose barb attachment. The EP-90R Water Pressure sensor, like the other LowranceNet Electronic Probe (EP) sensors, is designed for use with a NMEA 2000 DeviceNet Network. Your sensor, however, is also compatible ...

Page 3 - Installation; recommended; The hose-barb attachment

3 For complete instructions on setting up a new NMEA 2000 network or expanding an existing one, see the other document packed with your EP-90R, " Setup and Installation of NMEA 2000 Networks, General Information " part number 988-0154-173. If that document is not available, it can be downloa...

Page 5 - messages sent from a temperature sensor. A NMEA 2000 network; There are two types of LowranceNet red connectors: the single T; Network Backbone and Network Nodes; To pick up a phone and be able to hear a conversation from another

5 In similar fashion, a NMEA 2000 network allows multiple display units to receive data from a GPS antenna or multiple sonar units to receive messages sent from a temperature sensor. A NMEA 2000 network gives you the flexibility to view information like, engine diagnostics and fuel level data on dig...

Other Lowrance Models

All Lowrance Other