Page 2 - The NMEA 2000 red female to blue female adapter cable allows users; Tools and Supplies; LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot
2 The EP-90R consists of a red cable connector and the EP-90R housing with standard size hose barb attachment. The EP-90R Water Pressure sensor, like the other LowranceNet Electronic Probe (EP) sensors, is designed for use with a NMEA 2000 DeviceNet Network. Your sensor, however, is also compatible ...
Page 3 - Installation; recommended; The hose-barb attachment
3 For complete instructions on setting up a new NMEA 2000 network or expanding an existing one, see the other document packed with your EP-90R, " Setup and Installation of NMEA 2000 Networks, General Information " part number 988-0154-173. If that document is not available, it can be downloa...
Page 5 - messages sent from a temperature sensor. A NMEA 2000 network; There are two types of LowranceNet red connectors: the single T; Network Backbone and Network Nodes; To pick up a phone and be able to hear a conversation from another
5 In similar fashion, a NMEA 2000 network allows multiple display units to receive data from a GPS antenna or multiple sonar units to receive messages sent from a temperature sensor. A NMEA 2000 network gives you the flexibility to view information like, engine diagnostics and fuel level data on dig...
Page 6 - NMEA 2000 network node located at the end of a NMEA 2000 backbone.; Adding a Network Node
6 NMEA 2000 network node located at the end of a NMEA 2000 backbone. NOTE: If you have a double T Connector on your network that is not attached to a device, you must cap the unused connector with a NMEA 2000 cap. This will protect the pin connectors from corrosion. The NMEA 2000 cap looks like a te...
Page 7 - In this example, a new device is added to the NMEA 2000 bus by; Additional Network Information; came packed with this document.
7 In this example, a new device is added to the NMEA 2000 bus by installing a T connector between a T connector and a terminator at the end of the backbone (network bus). Additional Network Information For more information on creating or expanding a network refer to the NMEA 2000 network setup bookl...
Page 8 - Notes
Page 9 - Pressure Configuration; Boat Setup; To execute Boat Setup:
9 LMF-200: EP-90R Pressure Configuration This section covers how to use EP-90R Pressure Sensor with the LMF- 200 Multi-function gauge. NOTE: You will notice the LMF-200 does not have an Exit key. Menus will time out after a preset amount of time (3, 5, 10 or 15 seconds). The default setting is 5 sec...
Page 10 - Boat Setup Reset; Hit menu to reset Eng/Tnk; EP-90R Pressure Configuration; Hit Menu to Cfg Pres Snsr
10 4. Use the UP and DOWN keys to input the number of gallons the tank will hold and press MENU . Repeat steps 3 and 4 for each additional tank. After all tanks have been set up, you will be directed to the main display. Boat Setup Reset If you want to access the Setup screen (Boat Setup) after an e...
Page 11 - Hit Menu to Unset Dev; Displaying Pressure Sensor Data; Page Screen Rotation
11 To unconfigure the EP-90R: 1. Press MENU , select S YSTEM S ETUP and press MENU . 2. Highlight B US D EVICES and press MENU . Select a configured pressure sensor and press MENU . 3. The pressure sensor menu will appear. Highlight U NCONFIG and press MENU . The following message will appear: Hit M...
Page 12 - Customizing Pages
12 Adding a page: 1. Press MENU , use the UP and DOWN keys to select P AGES and press MENU , which will open the Pages menu with the following options: Add Page, Rem Page, Autoscroll and Set Pop-up. 2. Highlight A DD P AGE and press MENU . 3. Select Gauge, Single Digital or Dual Digital and press ME...
Page 14 - Press Menu to Rst Values
14 3. Select the desired option and press MENU . The Pressure Range menu will appear with the following options: 0-30 psi, 0-60 psi, 0-80 psi and 0-100 psi. 4. Select the desired PSI range and press MENU . Warning Threshold When you set a Warning Threshold for a pressure sensor, a pop-up window will...
Page 16 - Press ENTER to reset Eng/Tnk Cfg; Press Enter to Configure Pressure Snsr
16 5. After all tanks on your vessel have been set up, press EXIT repeatedly to return to the main display. Boat Setup Reset If you want to access the Setup screen (Boat Setup) after an engine- tank configuration has been chosen you will have to reset the configuration to default settings. To reset ...
Page 17 - Press Enter to add the selected page
17 4. Press ENTER . You will be taken back to the Bus Devices list. Press EXIT repeatedly to return to the main display. To reconfigure the EP-90R: 1. Press MENU , select S YSTEM S ETUP and press ENTER . 2. Highlight B US D EVICES and press ENTER . Select a configured pressure sensor and press ENTER...
Page 22 - Press Enter to Reset Values
22 To reset pressure sensor values: 1. Press MENU , select S YSTEM S ETUP and press ENTER . 2. Highlight B US D EVICES and press ENTER . 3. Select the desired pressure sensor and press ENTER . 4. Highlight R ESET V ALUES and press ENTER . The following message will appear: Press Enter to Reset Value...
Page 23 - The LMS-525cDF is one of many Lowrance display units that may be; Bus Setup
23 Display Unit: EP-90R Pressure Configuration This section will show you how to use an EP-90R Pressure Sensor with a display unit. The LMS-525cDF is one of many Lowrance display units that may be used with the EP-90R Pressure Sensor. NOTE: Your unit may have a NMEA 2000 menu or a Networking menu, d...
Page 24 - Engine & Tank Configuration; Bus Setup highlighted on the NMEA 2000 menu (left). Bus Setup
24 Engine & Tank Configuration The Engine-Tank configuration menu is located below the NMEA 2000 Devices list, but will only be accessible if engine- or fuel-related devices are on the network. When choosing an engine-tank configuration you will use the Tank Select menu, Tank Size dialog box and...
Page 25 - Engine/1Tank highlighted on Engine and Tank Configuration; Are you sure you wish to change the bus configuration?; EP-90R Pressure Sensor Configuration
25 9. When all tanks have been configured, highlight the S ET C ONFIGURATION button and press ENTER . The following confirmation message will appear: Are you sure you wish to change the bus configuration? Choose Y ES and press ENTER , Press EXIT to return to the main display. 1 Engine/1Tank highligh...
Page 27 - Are you sure you wish to change this; Restore Defaults; Are you sure you wish to change this device's configuration?
27 To select Pressure Type : 1. Press MENU twice, select NMEA 2000 or N ETWORKING and press ENTER . A menu will appear with five options: Bus Setup, Fuel Management, NMEA 2000 Alarms, Waypoint Sharing and Backlight Synchronization. 2. Highlight B US S ETUP and press ENTER , which will open the Bus C...
Page 28 - Alarm Status Tab
28 6. Highlight Y ES and press ENTER . Press EXIT repeatedly to return to the main display. NMEA 2000 Alarms When you set a NMEA 2000 Alarm for a pressure sensor, a pop-up window will appear and an alarm will sound when pressure exceeds or falls below a preset PSI level of your choosing. To turn on/...
Page 31 - LOWRANCE ELECTRONICS
31 LOWRANCE ELECTRONICS FULL ONE-YEAR WARRANTY "We," "our," or "us" refers to LOWRANCE ELECTRONICS, INC., the manufacturer of this product. "You" or "your" refers to the first person who purchases this product as a consumer item for personal, family or househo...
Page 32 - How to Obtain Service...; ...outside Canada and the USA:; Accessory Ordering Information
32 How to Obtain Service… …in the USA: Contact the Factory Customer Service Department. Call toll-free: For Lowrance: 800-324-1356. For Eagle: 800-324-1354 8 a.m. to 5 p.m. Central Standard Time, M-F Lowrance Electronics and Eagle Electronics may find it necessary to change or end their shipping pol...