DIAMETERS/PACKAGING

Diameter

33 Lb. (15kg)

in. (mm)

Plastic Spool Foil Bag

.045 (1.1)

ED030944

1/16 (1.6)

ED030945

Metalshield

MC-715

Mild Steel Metal-Cored Wire

(AWS E70C-6M H8)

Metalshield MC-715 is designed for virtually slag free deposits in single or multiple pass
welding applications. Its design achieves robust low temperature impacts and can be
used in semiautomatic and automatic applications. Excellent for welding over scale or
surface contaminants.

Advantage Lincoln

• Smooth, spray-type arc transfer and low spatter level.

• High deposition efficiency.

• Good resistance to porosity on mill scale.

• Excellent

"fast follow"

characteristics.

• Robust low temperature impact properties.

• Manufactured under a quality system certified to ISO 9001

requirements.

Welding Positions

Typical Applications

• Mining equipment

• Heavy equipment

• Offshore

• General structural fabrication

Shielding Gas

75-95% Argon / Balance CO2

Flow Rate: 30-45 CFH

Higher argon percentage will lower the amount of generated welding
fume. A 15-25% CO2 range may be used for improved arc

characteristics when welding in the short circuiting mode.

Conformance

AWS A5.18-01: E70C-6M H8
ASME SFA-5.18: E70C-6M H8
BV: SA3-3YMHH
ABS: 4Y403H
DNV: IV Y40H5
GL: 4Y40H5S
LR: 4Y40H5

Diffusible Hydrogen

-

As required per AWS A5.18-01

Requirements (AWS E70C-6M H8)

8.0

Test Results: 80% Ar/20% CO2

2.0 - 5.0

1F

1G

2F

2G

3G

3G

4G

Yield

Tensile

Strength

Strength

Elongation

Charpy V-Notch, ft•lbf (Joules)

psi (MPa)

psi (MPa)

(%)

@ -20ºF (-29ºC)

@-40°F(-40°C)

@-51°F(-46°C)

Requirements

58,000 (400)

70,000 (483)

22

20 (27)

Not Specified

Not Specified

AWS E70C-6M H8

min.

min.

min.

min.

Test Results
80% Ar/20% CO2

65,000-71,000

76,000-81,000 25-31

Exceeds

76-115

69-88

(460-490)

(527-556)

Requirements

(103-156)

(94-119)

MECHANICAL PROPERTIES – As Required per AWS A5.18-01